Clinical significance of intracranial hemorrhage after thrombectomy detected solely by magnetic resonance imaging and not by computed tomography

被引:0
作者
Suzuki, Kentaro [1 ]
Katano, Takehiro [1 ]
Numao, Shinichiro [1 ]
Nishi, Yuji [1 ]
Kutsuna, Akihito [1 ]
Kanamaru, Takuya [1 ]
Saito, Tomonari [1 ]
Aoki, Junya [1 ]
Nishiyama, Yasuhiro [1 ]
Kimura, Kazumi [1 ]
机构
[1] Nippon Med Sch, Dept Neurol, 1-1-5 Sendagi,Bunkyo Ku, Tokyo 1138602, Japan
关键词
Intracranial hemorrhage; Mechanical thrombectomy; MRI; ACUTE ISCHEMIC-STROKE; MECHANICAL THROMBECTOMY; INTRAVENOUS ALTEPLASE; MRI; TRANSFORMATION; MULTICENTER; PREDICTORS; SUBTYPE; BRAIN; ECHO;
D O I
10.1016/j.jns.2024.122999
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and objective: Whether intracranial hemorrhage (ICH) detected using magnetic resonance imaging (MRI) affects the clinical outcomes of patients with large-vessel occlusion (LVO) treated with mechanical thrombectomy (MT) remains unclear. This study investigated the clinical features of ICH after MT detected solely by MRI. Methods: This was a retrospective analysis of patients with acute ischemic stroke and occlusion of the internal carotid artery or middle cerebral artery treated with MT between April 2011 and March 2021. Among 632 patients, patients diagnosed with no ICH using CT, with a pre-morbid modified Rankin Scale (mRS) score <= 2, and those who underwent MRI including T2* and computed tomography (CT) within 72 h from MT were enrolled. The main outcomes were the association between ICH detected solely by MRI and clinical outcomes at 90 days. Poor clinical outcomes were defined as mRS score > 2 at 90 days after onset. Results: Of the 246 patients, 29 (12%) had ICH on MRI (MRI-ICH(+)), and 217 (88%) were MRI-ICH(-). There was no significant difference between number of patients with MRI-ICH(+) experiencing poor (10 [12%]) and favorable (19 [12%]) outcomes. The mRS score at 90 days between patients with MRI-ICH (+) and MRI-ICH(-) was not significantly different (2 [1-4] vs. 2 [1-4], respectively). Higher age and lower ASPECTS were independent risk factors for poor outcomes, as shown by multivariate regression analysis. MRI-ICH(+) status was not associated with poor outcomes. Conclusions: ICH detected by MRI alone did not influence clinical outcomes in patients with LVO treated with MT.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Computed Tomography and Magnetic Resonance Imaging Parameters Associated with Poor Clinical Outcome in Spondylodiscitis
    Foreman, Sarah C.
    Schwaiger, Benedikt J.
    Meyer, Bernhard
    Gersing, Alexandra S.
    Zimmer, Claus
    Gempt, Jens
    Kirschke, Jan S.
    WORLD NEUROSURGERY, 2017, 104 : 919 - +
  • [22] Imaging diagnosis of autoimmune pancreatitis: computed tomography and magnetic resonance imaging
    Ogawa, Hiroshi
    Takehara, Yasuo
    Naganawa, Shinji
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (04) : 565 - 571
  • [23] Magnetic Resonance Imaging and Computed Tomography Developments in Imaging of Venous Thromboembolism
    van Langevelde, Kirsten
    Tan, Melanie
    Sramek, Alexandr
    Huisman, Menno V.
    de Roos, Albert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (06) : 1302 - 1312
  • [24] Surgical results in hidden lumbar spinal stenosis detected by axial loaded computed tomography and magnetic resonance imaging
    Willen, Jan
    Wessberg, Per J.
    Danielsson, Barbro
    SPINE, 2008, 33 (04) : E109 - E115
  • [25] Magnetic Resonance Imaging of Idiopathic Intracranial Hypertension: Before and After Treatment
    Caglayan, Hale Z. Batur
    Ucar, Murat
    Hasanreisoglu, Murat
    Nazliel, Bijen
    Tokgoz, Nil
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2019, 39 (03) : 324 - 329
  • [26] Thoracic calcifications on magnetic resonance imaging: correlations with computed tomography
    Zampieri, Juliana Fischman
    Pacini, Gabriel Sartori
    Zanon, Matheus
    Leonhardt Altmayer, Stephan Philip
    Watte, Guilherme
    Barros, Marcelo
    Durayski, Evandra
    Portes Meirelles, Gustavo de Souza
    Guimaraes, Marcos Duarte
    Marchiori, Edson
    Souza Junior, Arthur Soares
    Hochhegger, Bruno
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2019, 45 (04)
  • [27] Computed tomography and magnetic resonance imaging features of cervical chordoma
    Cui, Jiu-Fa
    Hao, Da-Peng
    Chen, Hai-Song
    Liu, Ji-Hua
    Hou, Feng
    Xu, Wen-Jian
    ONCOLOGY LETTERS, 2018, 16 (01) : 861 - 865
  • [28] Optimizing neonatal cardiac imaging (magnetic resonance/computed tomography)
    Ramirez-Suarez, Karen, I
    Tierradentro-Garcia, Luis Octavio
    Otero, Hansel J.
    Rapp, Jordan B.
    White, Ammie M.
    Partington, Sara L.
    Harris, Matthew A.
    Vatsky, Seth A.
    Whitehead, Kevin K.
    Fogel, Mark A.
    Biko, David M.
    PEDIATRIC RADIOLOGY, 2022, 52 (04) : 661 - 675
  • [29] Computed Tomography, Magnetic Resonance Imaging, and Pathological Features of Gliosarcoma
    Fan, Haiqing
    Yu, Yue
    Du, Jinhui
    Liu, Likun
    Luo, Yilin
    Yu, Hui
    Liao, Xin
    NEUROPSYCHIATRIC DISEASE AND TREATMENT, 2022, 18 : 2577 - 2589
  • [30] Computed tomography and magnetic resonance imaging of peripelvic and periureteric pathologies
    Ekim Gumeler
    Mehmet Ruhi Onur
    Ali Devrim Karaosmanoglu
    Mustafa Ozmen
    Deniz Akata
    Musturay Karcaaltincaba
    Abdominal Radiology, 2018, 43 : 2400 - 2411