Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures

被引:28
作者
Cakmak, Gulce [1 ,4 ]
Cuellar, Alfonso Rodriguez [2 ]
Donmez, Mustafa Borga [3 ,4 ]
Abou-Ayash, Samir [5 ]
Lu, Wei-En [6 ]
Schimmel, Martin [7 ,8 ]
Yilmaz, Burak [7 ,9 ,10 ]
机构
[1] Univ Bern, Buser Fdn Scholar Implant Dent, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Clin Dent Rodriguez Dent Clin, Dept Periodontol, Mexico City, DF, Mexico
[3] Istinye Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkiye
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[5] Univ Bern, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dent, Bern, Switzerland
[6] Ohio State Univ, Coll Publ Hlth, Div Biostat, Columbus, OH USA
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[8] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[9] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[10] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
关键词
MARGINAL ADAPTATION; 4-UNIT FDPS; IN-VITRO; FIT; ACCURACY; CROWNS; ZIRCONIA; COCR;
D O I
10.1016/j.prosdent.2022.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Three-dimensional printing has facilitated the fabrication processes in dentistry. However, knowledge on the effect of layer thickness on the trueness of 3D printed fixed partial dentures (FPDs) is lacking. Purpose. The purpose of this in vitro study was to compare the effect of printing layer thickness on the trueness of 3-unit interim FPDs fabricated by using additive manufacturing with that of those fabricated by subtractive manufacturing. Material and methods. The right first premolar and first molar teeth of a dentate mandibular model were prepared for a 3-unit restoration and then digitized by using an intraoral scanner. A 3-unit interim FPD was designed to fabricate 40 restorations by using either the additive (NextDent C&B MFH) with layer thicknesses of 20 mu m (n=10), 50 mu m (n=10), and 100 mu m (n=10) or subtractive manufacturing technique (Upcera) (milled, n=10). After fabrication, the interim FPDs were digitized by using the same intraoral scanner and were superimposed over the design data by using a 3D analysis software program. Root mean square (RMS) was used to analyze the trueness of the restorations at 4 different surfaces (external, intaglio, marginal area, and intaglio occlusal) and as a complete unit (overall). Data were analyzed with the Kruskal-Wallis and Wilcoxon tests with Bonferroni correction (a=.05). Results. The 100-mu m-layer thickness interim FPDs showed the greatest overall (P<.015), external (P<.021), and intaglio occlusal (P<.021) deviations, whereas the milled interim FPDs showed the lowest (P=.001). No significant differences were found among the test groups for marginal RMS (P >=.108). The differences between the 50-<mu>m-layer thickness and 100-mu m-layer thickness interim FPDs for the intaglio surface deviations (P=.064) and between the 20-mu m-layer thickness and 50 mu m-layer thickness interim FPDs for each surface tested were not statistically significant (P>.108). Conclusions. The printing layer thickness had a significant effect on the trueness of the additively trueness than those additively manufactured, regardless of the printing layer thickness.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 47 条
  • [21] Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system
    Lee, Wan-Sun
    Lee, Du-Hyeong
    Lee, Kyu-Bok
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04) : 265 - 270
  • [22] Evaluation of the accuracy of orthodontic models prototyped with entry-level LCD-based 3D printers: a study using surface-based superimposition and deviation analysis
    Lo Giudice, Antonino
    Ronsivalle, Vincenzo
    Rustico, Lorenzo
    Aboulazm, Kaled
    Isola, Gaetano
    Palazzo, Giuseppe
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (01) : 303 - 312
  • [23] Fit of interim crowns fabricated using photopolymer-jetting 3D printing
    Mai, Hang-Nga
    Lee, Kyu-Bok
    Lee, Du-Hyeong
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) : 208 - 215
  • [24] The potential of additive manufacturing technologies and their processing parameters for the fabrication of all-ceramic crowns: A review
    Methani, Mohammad Mujtaba
    Revilla-Leon, Marta
    Zandinejad, Amirali
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (02) : 182 - 192
  • [25] Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment
    O'Toole, Saoirse
    Osnes, Cecilie
    Bartlett, David
    Keeling, Andrew
    [J]. DENTAL MATERIALS, 2019, 35 (03) : 495 - 500
  • [26] Osman RB, 2017, INT J PROSTHODONT, V30, P182, DOI 10.11607/ijp.5117
  • [27] Implant framework misfit: A systematic review on assessment methods and clinical complications
    Pan, Yu
    Tsoi, James K. H.
    Lam, Walter Y. H.
    Pow, Edmond H. N.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (02) : 244 - 258
  • [28] Evaluation of laboratory scanner accuracy by a novel calibration block for complete-arch implant rehabilitation
    Pan, Yu
    Tam, Juliana M. Y.
    Tsoi, James K. H.
    Lam, Walter Y. H.
    Huang, Ruoxuan
    Chen, Zhuofan
    Pow, Edmond H. N.
    [J]. JOURNAL OF DENTISTRY, 2020, 102
  • [29] Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques
    Papadiochou, Sofia
    Pissiotis, Argirios L.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) : 545 - 551
  • [30] Effects of Printing Parameters on the Fit of Implant-Supported 3D Printing Resin Prosthetics
    Park, Gang-Seok
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    Seo, Deog-Gyu
    [J]. MATERIALS, 2019, 12 (16)