Study of the Bunsen-Roscoe Reciprocity Law in Solar Water Disinfection (Optical Effect) for E. coli, E. faecalis and C. perfringens

被引:0
作者
Torres, Julia [1 ]
Palacios, Ana Maria [1 ]
Fuentes, Manuel [1 ]
Vivar, Marta [1 ]
机构
[1] Univ Jaen, Grp IDEA, EPS Linares, Linares 23700, Spain
关键词
reciprocity; UV disinfection; solar energy; E; coli; faecalis; wastewater; ESCHERICHIA-COLI; DRINKING-WATER; SALMONELLA-TYPHIMURIUM; SHIGELLA-FLEXNERI; INACTIVATION; UV; TEMPERATURE; BACTERIA; SODIS;
D O I
10.3390/w16101406
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water stress and water quality represent major environmental challenges in the 21st century. In response, wastewater management and its potential reuse emerge as strategies to mitigate these problems. This research aims to verify the law of reciprocity in the solar disinfection process of real secondary wastewater effluents for different faecal microorganisms. Flat disinfection reactors, subjected only to natural and continuous UV radiation, were used. The study focused on the optical effect of UV radiation, eliminating the significant influence of the thermal effect and its synergy in solar disinfection at temperatures above 45 degrees C, by controlling the temperatures of the water samples to levels below 20 degrees C. Three experimental tests were carried out on sunny days. Each test comprised two trials, under the following conditions: (a) low solar irradiance over a prolonged time (duration approximately: 2.6 h) and (b) high solar irradiance and a shorter period of time (approximately 2 h), with each receiving the same UV dose. Inactivation kinetics was analysed for E. coli, E. faecalis, and C. perfringens (including spores). The results validated the reciprocity law for E. coli in all tests for UV doses > 20 Wh/m2, showing no significant deviations, with inactivation rates of 0.44 to 0.51 m2/Wh for initial concentrations of 106-107 CFU/100 mL. In contrast, for E. faecalis, the reciprocity was only valid at intensities < 700 W/m2, with rates of 0.04 and 0.035 m2/Wh for 105-106 CFU/100 mL; above this irradiance value, the law varied significantly and was not valid. C. perfringens did not show significant disinfection results during the experiments to verify this law, mainly due to the resistance of its spores. Additional experimentation with C. perfringens is necessary, by extending the length of the experiments and/or conducting them at higher irradiance values, in order to reach bacterial inactivation to enable the analysis of the reciprocity law. In general, the main conclusion from these results is that the reciprocity law in solar disinfection would be difficult to use for the estimation of water solar disinfection based on the irradiance and exposure times, as there are deviations from it at least in one specie (E. faecalis). Mores studies should be carried out to fully understand and determine the validity of this law and its potential application for forecasting solar water disinfection.
引用
收藏
页数:18
相关论文
共 29 条
[1]  
Albrecht J.A., 2005, Clostridium Perfringens
[2]  
[Anonymous], 2013, UNE-EN ISO 14189:2013 Water Quality-Enumeration of Clostridium Perfringens-Method Using Membrane Filtration
[3]  
[Anonymous], 2014, UNE-EN ISO 9308-1:2014
[4]  
[Anonymous], 2012, Bad Bug Book, Handbook of Foodborne Pathogenic Microorganisms and Natural Toxins
[5]  
[Anonymous], 2000, UNE-EN ISO 7899-2:2000 Water quality-Detection and Enumeration of Intestinal Enterococci. Part 2: Membrane Filtration Method
[6]   Efficacy of solar disinfection of Escherichia coli, Shigella flexneri, Salmonella Typhimurium and Vibrio cholerae [J].
Berney, M. ;
Weilenmann, H. -U. ;
Simonetti, A. ;
Egli, T. .
JOURNAL OF APPLIED MICROBIOLOGY, 2006, 101 (04) :828-836
[7]   Solar disinfection (SODIS) and subsequent dark storage of Salmonella typhimurium and Shigella flexneri monitored by flow cytometry [J].
Bosshard, Franziska ;
Berney, Michael ;
Scheifele, Michael ;
Weilenmann, Hans-Ulrich ;
Egli, Thomas .
MICROBIOLOGY-SGM, 2009, 155 :1310-1317
[8]  
Bunsen R.W., 1863, Ann. Phys, V193, P529, DOI [10.1002/andp.18631931202, DOI 10.1002/ANDP.18631931202, DOI 10.1002/ANDP.18631931202.]
[9]  
Estacion Depuradora de Aguas Residuales (EDAR) de Linares, Proceso de Depuracion
[10]   Temperature-dependent change of light dose effects on E-coli inactivation during simulated solar treatment of secondary effluent [J].
Giannakis, Stefanos ;
Darakas, Efthymios ;
Escalas-Canellas, Antoni ;
Pulgarin, Cesar .
CHEMICAL ENGINEERING SCIENCE, 2015, 126 :483-487