Magnetic Particle Imaging-Guided Thermal Simulations for Magnetic Particle Hyperthermia

被引:3
作者
Carlton, Hayden [1 ]
Arepally, Nageshwar [2 ]
Healy, Sean [1 ]
Sharma, Anirudh [1 ]
Ptashnik, Sarah [3 ]
Schickel, Maureen [3 ]
Newgren, Matt [4 ]
Goodwill, Patrick [4 ]
Attaluri, Anilchandra [2 ]
Ivkov, Robert [1 ,5 ,6 ,7 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21205 USA
[2] Penn State Univ Harrisburg, Sch Sci Engn & Technol, Dept Mech Engn, Middletown, PA 17057 USA
[3] Materialise NV, B-3001 Leuven, Belgium
[4] Magnet Insight Inc, Alameda, CA 94502 USA
[5] Johns Hopkins Univ, Sch Med, Dept Oncol, Sydney Kimmel Comprehens Canc Ctr, Baltimore, MD 21205 USA
[6] Johns Hopkins Univ, Whiting Sch Engn, Dept Mech Engn, Baltimore, MD 21218 USA
[7] Johns Hopkins Univ, Whiting Sch Engn, Dept Mat Sci & Engn, Baltimore, MD 21218 USA
基金
美国国家卫生研究院;
关键词
magnetic nanoparticles; magnetic particle imaging; magnetic hyperthermia; image guidance; finite element analysis; RADIATION-THERAPY; TEMPERATURE; SYSTEM; OPTIMIZATION; TISSUE; NANOPARTICLES; VALIDATION; DAMAGE; TIME;
D O I
10.3390/nano14121059
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Magnetic particle hyperthermia (MPH) enables the direct heating of solid tumors with alternating magnetic fields (AMFs). One challenge with MPH is the unknown particle distribution in tissue after injection. Magnetic particle imaging (MPI) can measure the nanoparticle content and distribution in tissue after delivery. The objective of this study was to develop a clinically translatable protocol that incorporates MPI data into finite element calculations for simulating tissue temperatures during MPH. To verify the protocol, we conducted MPH experiments in tumor-bearing mouse cadavers. Five 8-10-week-old female BALB/c mice bearing subcutaneous 4T1 tumors were anesthetized and received intratumor injections of Synomag (R)-S90 nanoparticles. Immediately following injection, the mice were euthanized and imaged, and the tumors were heated with an AMF. We used the Mimics Innovation Suite to create a 3D mesh of the tumor from micro-computerized tomography data and spatial index MPI to generate a scaled heating function for the heat transfer calculations. The processed imaging data were incorporated into a finite element solver, COMSOL Multiphysics (R). The upper and lower bounds of the simulated tumor temperatures for all five cadavers demonstrated agreement with the experimental temperature measurements, thus verifying the protocol. These results demonstrate the utility of MPI to guide predictive thermal calculations for MPH treatment planning.
引用
收藏
页数:15
相关论文
共 54 条
[1]   Temperature distribution as function of time around a small spherical heat source of local magnetic hyperthermia [J].
Andrä, W ;
d'Ambly, CG ;
Hergt, R ;
Hilger, I ;
Kaiser, WA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1999, 194 (1-3) :197-203
[2]  
[Anonymous], 1994, Guidelines for evaluating and expressing the uncertainty of NIST measurement results, V1994
[3]   Magnetic nanoparticle hyperthermia enhances radiation therapy: A study in mouse models of human prostate cancer [J].
Attaluri, Anilchandra ;
Kandala, Kamal ;
Wabler, Michele ;
Zhou, Haoming ;
Cornejo, Christine ;
Armour, Michael ;
Hedayati, Mohammad ;
Zhang, Yonggang ;
DeWeese, Theodore L. ;
Herman, Cila ;
Ivkov, Robert .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2015, 31 (04) :359-374
[4]  
Banura N, 2016, Arxiv, DOI arXiv:1605.08139
[5]  
Behrends Andre, 2024, Nanotheranostics, V8, P163, DOI 10.7150/ntno.90360
[6]   Relating Magnetic Properties and High Hyperthermia Performance of Iron Oxide Nanoflowers [J].
Bender, Philipp ;
Fock, Jeppe ;
Frandsen, Cathrine ;
Hansen, Mikkel F. ;
Balceris, Christoph ;
Ludwig, Frank ;
Posth, Oliver ;
Wetterskog, Erik ;
Bogart, Lara K. ;
Southern, Paul ;
Szczerba, Wojciech ;
Zeng, Lunjie ;
Witte, Kerstin ;
Gruettner, Cordula ;
Westphal, Fritz ;
Honecker, Dirk ;
Gonzalez-Alonso, David ;
Fernandez Barquin, Luis ;
Johansson, Christer .
JOURNAL OF PHYSICAL CHEMISTRY C, 2018, 122 (05) :3068-3077
[7]  
Brizel DM, 1996, CANCER RES, V56, P5347
[8]   In situ theranostic platform combining highly localized magnetic fluid hyperthermia, magnetic particle imaging, and thermometry in 3D [J].
Buchholz, Oliver ;
Sajjamark, Kulthisa ;
Franke, Jochen ;
Wei, Huimin ;
Behrends, Andre ;
Muenkel, Christian ;
Gruettner, Cordula ;
Levan, Pierre ;
von Elverfeldt, Dominik ;
Graeser, Matthias ;
Buzug, Thorsten ;
Baer, Sebastien ;
Hofmann, Ulrich G. .
THERANOSTICS, 2023, 14 (01) :324-340
[9]   HYPER: pre-clinical device for spatially-confined magnetic particle hyperthermia [J].
Carlton, Hayden ;
Weber, Matthias ;
Peters, Maximilian ;
Arepally, Nageshwar ;
Lad, Yash Sharad ;
Jaswal, Anshul ;
Ivkov, Robert ;
Attaluri, Anilchandra ;
Goodwill, Patrick .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2023, 40 (01)
[10]   A new method to measure magnetic nanoparticle heating efficiency in non-adiabatic systems using transient pulse analysis [J].
Carlton, Hayden ;
Ivkov, Robert .
JOURNAL OF APPLIED PHYSICS, 2023, 133 (04)