Numerical Investigation of Fiber Reinforced Polymer Retrofitted Short Reinforced Concrete Circular Columns under Concentric Compressive Load

被引:1
作者
Parghi, A. [1 ]
Patel, M. [1 ]
Lunagaria, M. H. [1 ]
机构
[1] Sardar Vallabhbhai Natl Inst Technol, Dept Civil Engn, Surat, Gujarat, India
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2024年 / 37卷 / 10期
关键词
Fiber Reinforced Polymer; Circular Reinforced Concrete Columns; Retrofitting; Pre-Load; Finite Element Method; MECHANICAL-PROPERTIES; FRP; STRENGTH; BEHAVIOR; CARBON; DAMAGE; WATER; MODEL; BARS;
D O I
10.5829/ije.2024.37.10a.02
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The presents study numerically investigates the fiber-reinforced polymer (FRP) retrofitted short-damaged reinforced concrete (RC) columns subjected to axial compression load. The main parameter considered to evaluate the effectiveness of FRP retrofitting on circular columns with different aspect ratios, concrete grade, and FRP material. To simulate the behaviour of a short RC column under a uniaxial compression load, a finite element model of the column was developed. The model was then modified to simulate the various level of damage to the column and the behaviour of the column under uniaxial load. The effectiveness of FRP retrofit was studied comparing the behaviour of the retrofitted column to the damaged column. For M20 concrete column retrofitted with carbon fiber reinforced polymer (CFRP) showed a higher strength (2 to 3 times) than glass fiber reinforced polymer (GFRP) retrofitted columns. For M30 concrete, the range is quite similar (1.5 - 2.3 times more). The effectiveness of both FRPs retrofitted columns increases with increasing aspect ratio from 2 and 3, but slightly decreases for an aspect ratio of 4 compared to the damaged specimen. The maximum effectiveness achieved for CFRP retrofitted columns is of 19.45% and for GFRP retrofitted column is of 10.71%, and the other grade of concrete (M30) followed a similar trend. The load-bearing capacity of columns has no significant effect by the increase in aspect ratio from 2 to 4.
引用
收藏
页码:1882 / 1890
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 2014, ABAQUS 614 ANAL USER, P14
[2]   Effect of Sequential Exposure to UV Radiation and Water Vapor Condensation and Extreme Temperatures on the Mechanical Properties of GFRP Bars [J].
Ashrafi, Hamed ;
Bazli, Milad ;
Oskouei, Asghar Vatani ;
Bazli, Leila .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (01)
[3]   The effect of mechanical and thermal properties of FRP bars on their tensile performance under elevated temperatures [J].
Ashrafi, Harried ;
Bazli, Milad ;
Najafabadi, Esmaeil Pournamazian ;
Oskouei, Asghar Vatani .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 157 :1001-1010
[4]   Effects of UV radiation, moisture and elevated temperature on mechanical properties of GFRP pultruded profiles [J].
Bazli, Milad ;
Jafari, Armin ;
Ashrafi, Hamed ;
Zhao, Xiao-Ling ;
Bai, Yu ;
Raman, R. K. Singh .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 231
[5]   Experiments and probabilistic models of bond strength between GFRP bar and different types of concrete under aggressive environments [J].
Bazli, Milad ;
Ashrafi, Hamed ;
Oskouei, Asghar Vatani .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 148 :429-443
[6]  
Benzaid R., 2013, INTECH. Fiber Reinforced Polymers-The Technology Applied for Concrete Repair, P167
[7]   Structural assessment of the coupled influence of corrosion damage and seismic force on the cyclic behaviour of RC columns [J].
Biswas, R. K. ;
Iwanami, M. ;
Chijiwa, N. ;
Nakayama, K. .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 304
[8]  
CARREIRA DJ, 1985, J AM CONCRETE I, V82, P797
[9]   Effect of cutter geometry on machining induced damage in orthogonal cutting of UD polymer composites: FE study [J].
Cepero-Mejias, F. ;
Curiel-Sosa, J. L. ;
Zhang, C. ;
Phadnis, V. A. .
COMPOSITE STRUCTURES, 2019, 214 :439-450
[10]   Investigation of insulated FRP-wrapped reinforced concrete columns in fire [J].
Chowdhury, Ershad U. ;
Bisby, Luke A. ;
Green, Mark F. ;
Kodur, Venkatesh K. R. .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :452-460