A coumarin-naphthalimide-based ratiometric fluorescent probe for nitroxyl (HNO) based on an ICT-FRET mechanism

被引:0
|
作者
Ma, Qiujuan [1 ,2 ]
Liu, Shuangyu [1 ]
Xu, Junhong [3 ]
Mao, Guojiang [4 ]
Wang, Gege [1 ]
Hou, Shuqi [1 ]
Ma, Yijie [1 ]
Lian, Yujie [1 ]
机构
[1] Henan Univ Chinese Med, Sch Pharm, Zhengzhou 450046, Peoples R China
[2] Henan Engn Res Ctr Modern Chinese Med Res Dev & Ap, Zhengzhou 450046, Peoples R China
[3] North China Univ Water Resources & Elect Power, Dept Elect Engn, Zhengzhou 450011, Peoples R China
[4] Henan Normal Univ, Sch Chem & Chem Engn, Xinxiang 453007, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitroxyl; Ratiometric fluorescent probe; Coumarin-naphthalimide; ICT-FRET; Cell imaging; VISUALIZATION;
D O I
10.1016/j.saa.2024.124876
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Nitroxyl (HNO) is an important reactive nitrogen that is associated with various states in physiology and pathology and plays a unique function in living systems. So, it is important to exploit fluorescent probes with high sensitivity and selectivity for sensing HNO. In this paper, a novel ratiometric fluorescent probe for HNO was developed utilizing intramolecular charge transfer (ICT) and fluorescence resonance energy transfer (FRET) mechanisms. The probe selected coumarin as energy donor, naphthalimide as energy receptor and 2-(diphenylphosphino)benzoate as the sensing site for detecting HNO. When HNO was not present, the 2-(diphenylphosphino)benzoate unit of the probe restricted electron transfer and the ICT process could not occur, leading to the inhibition of FRET process as well. Thus, in the absence of HNO the probe displayed the intrinsic blue fluorescence of coumarin. When HNO was added, the HNO reacted with the 2-(diphenylphosphino)benzoate unit of the probe to yield a hydroxyl group which resulting in the opening of ICT process and the occurring of FRET process. Thus, after providing HNO the probe displayed yellow fluorescence. In addition, the probe showed good linearity in the ratio of fluorescence intensity at 545 nm and 472 nm (I545 nm/I472 nm) with a concentration of HNO (0.1-20 mu M). The probe processed a detection limit of 0.014 mu M and a response time of 4 min. The probe also specifically identified HNO over a wide pH scope (pH = 4.00-10.00), including physiological conditions. Cellular experiments had shown that this fluorescent probe was virtually non-cytotoxic and could be applied for ratiometric sensing of HNO in A549 cells.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A ratiometric fluorescent probe based on FRET for selective monitoring of tungsten in living cells
    Nazir, Rahila
    Soleja, Neha
    Agrawal, Neha
    Siddiqi, Tariq Omar
    Mohsin, Mohd
    JOURNAL OF MOLECULAR STRUCTURE, 2022, 1263
  • [42] Versatile Ratiometric Fluorescent Probe Based on the Two-Isophorone Fluorophore for Sensing Nitroxyl
    Li, Huan
    Wang, Chengcheng
    Cai, Lei
    Yu, Xiang
    Wu, Luling
    Yuan, Nannan
    Zhu, Yiming
    Jia, Nengqin
    James, Tony D.
    Huang, Chusen
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2021, 60 (44) : 15913 - 15920
  • [43] Development of a ratiometric fluorescent probe for sulfite based on a coumarin-benzopyrylium platform
    Chen, Yanhong
    Wang, Xin
    Yang, Xiao-Feng
    Zhong, Yaogang
    Li, Zheng
    Li, Hua
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 268 - 275
  • [44] A ratiometric fluorescent probe for sensing HOCl based on a coumarin-rhodamine dyad
    Zhang, Yan-Ru
    Chen, Xin-Peng
    Jing-Shao
    Zhang, Jia-Yi
    Yuan, Qiong
    Miao, Jun-Ying
    Zhao, Bao-Xiang
    CHEMICAL COMMUNICATIONS, 2014, 50 (91) : 14241 - 14244
  • [45] An ICT-based fluorescent probe for ratiometric monitoring the fluctuations of peroxynitrite in mitochondria
    Cui, Jie
    Zang, Shunping
    Nie, Hailiang
    Shen, Tiaojiao
    Su, Sa
    Jing, Jing
    Zhang, Xiaoling
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 328
  • [46] A ratiometric Al3+ ion probe based on the coumarin-quinoline FRET system
    Zhu, Qin
    Li, Li
    Mu, Lan
    Zeng, Xi
    Redshaw, Carl
    Wei, Gang
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2016, 328 : 217 - 224
  • [47] An effective colorimetric and ratiometric fluorescent probe based FRET with a large Stokes shift for bisulfite
    Wen-Li Wu
    Zhao-Yang Wang
    Xi Dai
    Jun-Ying Miao
    Bao-Xiang Zhao
    Scientific Reports, 6
  • [48] A ratiometric fluorescent probe based on the FRET platform for the detection of sulfur dioxide derivatives and viscosity
    Liu, Feng-Ting
    Jiang, Peng-Fei
    Wang, Yan-Pu
    Zhao, Bao-Xiang
    Lin, Zhao-Min
    ANALYTICA CHIMICA ACTA, 2024, 1288
  • [49] A mitochondria-targeting ratiometric fluorescent probe for the detection of hypochlorite based on the FRET strategy
    Shen, Shi-Li
    Zhang, Xiao-Fan
    Ge, Yan-Qing
    Zhu, Yan
    Cao, Xiao-Qun
    RSC ADVANCES, 2017, 7 (87): : 55296 - 55300
  • [50] An effective colorimetric and ratiometric fluorescent probe based FRET with a large Stokes shift for bisulfite
    Wu, Wen-Li
    Wang, Zhao-Yang
    Dai, Xi
    Miao, Jun-Ying
    Zhao, Bao-Xiang
    SCIENTIFIC REPORTS, 2016, 6