Pipeline versus non-pipeline flow diverter treatment for M1 aneurysms: A systematic review and meta-analysis

被引:0
作者
Senol, Yigit Can [1 ]
Orscelik, Atakan [2 ]
Bilgin, Cem [2 ]
Kobeissi, Hassan [2 ]
Ghozy, Sherief [2 ]
Arul, Santhosh [2 ]
Kallmes, David F. [2 ]
Kadirvel, Ramanathan [1 ]
机构
[1] Mayo Clin, Dept Neurol Surg, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
Pipeline; flow diverter; M1; aneurysm; CEREBRAL-ARTERY ANEURYSMS; ENDOVASCULAR MANAGEMENT; DIVERSION; COILING; EFFICACY; DEVICE; SAFETY; CIRCLE; WILLIS;
D O I
10.1177/19714009241260805
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background: The flow diversion treatment of aneurysms located distal to the Circle of Willis has recently increased in frequency. We conducted a systematic review and meta-analysis of the clinical and radiological outcomes of flow diverter (FD) embolization in treating M1 aneurysms. Methods: PubMed, Web of Science, Ovid Medline, Ovid Embase, and Scopus were searched up to May 2024 using the Nested Knowledge platform. We included studies assessing the long-term clinical and radiological outcomes for M1 aneurysms. Results of FDs classified as Pipeline Embolization Devices (PED) versus other types of FDs. Angiographic occlusion rates, ischemic and hemorrhagic complications, and favorable clinic outcomes were included. All data were analyzed using R software version 4.2.2. Results: Thirteen studies with 112 total patients (58 patients for PED and 54 patients for other FD devices) were included in our meta-analysis. The overall adequate (complete + near-complete) occlusion rates were 85.1%. The complete occlusion rate was higher with PED than with other FD devices (72.9% PED and 41.6% for non-PED FDs, respectively, p-value <.01). The ischemic complications were 9.9% and 9.0% for the PED and non-PED groups, respectively (p-value = .89). The overall modified Rankin Scale 0-2 was 100% for the non-PED and 97.1% for the PED group (p-value = .51). In-stent stenosis rate was 7.5% for PED devices compared to 2.6% in the non-PED group (p-value = .35). Conclusions: This relatively small meta-analysis showed high rates of adequate and complete occlusion in FD treatment of M1 segment aneurysms, with favorable safety profiles. PEDs were associated with higher rates of complete aneurysm occlusion compared to other types of FDs.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
[41]   Risk Factors for In-Stent Stenosis After Flow Diverter Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis of 2350 Patients [J].
Abramyan, Arevik ;
Roychowdhury, Sudipta ;
Tarasova, Natalia ;
Sioutas, Georgios ;
Samaan, Mena ;
Mangla, Sherry ;
Sundararajan, Srihari ;
Gupta, Gaurav .
NEUROSURGERY, 2025, 96 (05) :958-967
[42]   Flow diversion for distal cerebral aneurysms: a systematic review and meta-analysis [J].
Gunkan, Ahmet ;
Vilardo, Marina ;
Scarramal, Joao Paulo Liute ;
Elek, Alperen ;
Bocanegra-Becerra, Jhon E. ;
Cardoso, Leonardo Januario Campos ;
Dmytriw, Adam A. ;
Alexandre, Andrea Maria ;
Consoli, Arturo ;
Pereira, Vitor M. ;
Onal, Yilmaz ;
Clarencon, Frederic ;
Scarcia, Luca .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2025,
[43]   Efficacy of Flow-Diverting Devices for Cerebral Aneurysms: A Systematic Review and Meta-analysis [J].
Zhou, Geng ;
Su, Ming ;
Zhu, Yue-Qi ;
Li, Ming-Hua .
WORLD NEUROSURGERY, 2016, 85 :252-262
[44]   Pipeline Flow-Diverter Stent for Endovascular Treatment of Intracranial Aneurysms: Preliminary Experience in 20 Patients with 27 Aneurysms [J].
Lubicz, Boris ;
Collignon, Laurent ;
Raphaeli, Gai ;
De Witte, Olivier .
WORLD NEUROSURGERY, 2011, 76 (1-2) :114-119
[45]   Safety and efficiency of flow diverters for treating small intracranial aneurysms: A systematic review and meta-analysis [J].
Yao, Xiyang ;
Ma, Junwei ;
Li, Haiying ;
Shen, Haitao ;
Lu, Xiaojun ;
Chen, Gang .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2017, 45 (01) :11-21
[46]   Long-Term Durability of Open Surgical versus Endovascular Repair of Intracranial Aneurysms: A Systematic Review and Meta-Analysis [J].
Hulsbergen, Alexander F. C. ;
Mirzaei, Lida ;
van der Boog, Arthur T. J. ;
Smith, Timothy R. ;
Muskens, Ivo S. ;
Broekman, Marike L. D. ;
Mekary, Rania A. ;
Moojen, Wouter A. .
WORLD NEUROSURGERY, 2019, 132
[47]   Safety and efficacy profile of off-label use of the Pipeline Embolization Device: A systematic review and meta-analysis [J].
Senol, Yigit Can ;
Orscelik, Atakan ;
Bilgin, Cem ;
Kobeissi, Hassan ;
Ghozy, Sherief ;
Arul, Santhosh ;
Kallmes, David F. ;
Kadirvel, Ramanathan .
JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2024, 33 (04)
[48]   Efficacy of pipeline embolization device vs. traditional coils in embolization of intracranial aneurysms: A systematic review and meta-analysis [J].
Li, Wei ;
Xiao, Zaixing ;
Zhao, Kaixuan ;
Yang, Shijie ;
Zhang, Yichuan ;
Li, Bin ;
Zhou, Yu ;
Ma, Yong ;
Chai, Erqing .
FRONTIERS IN NEUROLOGY, 2022, 13
[49]   Flow-Diverting Devices versus Coil Embolization for Intracranial Aneurysms: A Systematic Literature Review and Meta-analysis [J].
Zhou, Geng ;
Zhu, Yue-Qi ;
Su, Ming ;
Gao, Kai-Di ;
Li, Ming-Hua .
WORLD NEUROSURGERY, 2016, 88 :640-645
[50]   Treatment of Unruptured Distal Anterior Circulation Aneurysms with Flow-Diverter Stents: A Meta-Analysis [J].
Cagnazzo, F. ;
Perrini, P. ;
Dargazanli, C. ;
Lefevre, P-H ;
Gascou, G. ;
Morganti, R. ;
di Carlo, D. ;
Derraz, I ;
Riquelme, C. ;
Bonafe, A. ;
Costalat, V .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (04) :687-693