The accuracy of ultrasound scan in diagnosing retained products of conception: a systematic review and meta-analysis

被引:3
|
作者
Sundararajan, Srividya [1 ]
Roy, Subhadeep [2 ]
Polanski, Lukasz T. [3 ]
机构
[1] East Suffolk & North Essex NHS Trust, Ipswich Gen Hosp, Dept Obstet & Gynaecol, Ipswich, England
[2] West Suffolk Hosp NHS Trust, Dept Obstet & Gynaecol, Bury St Edmunds, England
[3] North West Anglia NHS Fdn Trust, Peterborough City Hosp, Dept Obstet & Gynaecol, Peterborough, England
关键词
cesarean; Doppler; endometrium; miscarriage; retained products of conception; termination; transvaginal ultrasonography; COLOR DOPPLER; TRANSVAGINAL SONOGRAPHY; SENSITIVITY; MANAGEMENT; PREGNANCY;
D O I
10.1016/j.ajog.2023.11.1243
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: This study aimed to analyze and summarize the evidence on the accuracy of different ultrasound methods in the diagnosis of retained products of conception. DATA SOURCES: We searched Ovid SP, the Cumulative Register to Nursing & Allied Health Literature, EBSCO, and grey literature including STUDY ELIGIBILITY CRITERIA: We included prospective and retrospective cross-sectional or Cohort studies that evaluated both ultrasound findings (before management of retained products of conception) and histopathologic results of retained products of conception at all gestational ages. METHODS: We used Covidence for data extraction from the studies and quality assessment. The meta-analysis was performed using RevMan 5.4 (forest plot), MetaDTA version 2.01, and Meta-DiSc 2.0 online software. RESULTS: In total, 11 studies were eligible for data extraction and meta-analysis. The total number of study participants from these 11 studies were 1567. Of these, 9 studies were included to test the accuracy of an echogenic mass, 4 studies analyzed the accuracy of endometrial thickness, and 5 studies analyzed the accuracy of color Doppler flow to predict retained products of conception. We found that echogenic mass had the highest sensitivity, specificity, and diagnostic odds ratio for predicting retained products of conception. The sensitivity, specificity, and diagnostic odds ratio were 0.915 (95% confidence interval, 0.844-0.955), 0.843 (95% confidence interval, 0.615-0.947), and 57.787 (95% confidence interval, 15.171-220.112), respectively. The diagnostic threshold for endometrial thickness was set at 10 mm with a sensitivity, specificity, and diagnostic odds ratio of 0.667 (95% confidence interval, 0.072-0.981), 0.866 (95% confidence interval, 0.375-0.986), and 12.927 (95% confidence interval, 0.23-726.582). The sensitivity, specificity, and diagnostic odds ratio of color Doppler flow were 0.850 (95% confidence interval, 0.756-0.913), 0.406 (95% confidence interval, 0.198-0.655), and 3.893 (95% confidence interval, 1.005-15.081). CONCLUSION: Our review concluded that an echogenic mass is the most sensitive and specific predictor of retained products of conception after any pregnancy event. The most important limitation of our review is that the design of the studies included led to significant statistical heterogeneity.
引用
收藏
页码:512 / 531.e3
页数:23
相关论文
共 50 条
  • [21] Fertility outcome after treatment of retained products of conception: a systematic review
    Hamerlynck, Tjalina W. O.
    Meyers, Dora
    Van der Veken, Hannelore
    Bosteels, Jan
    Weyers, Steven
    GYNECOLOGICAL SURGERY, 2018, 15
  • [22] Accuracy of prenatal ultrasound in detecting jejunal and ileal atresia: systematic review and meta-analysis
    Virgone, C.
    D'Antonio, F.
    Khalil, A.
    Jonh, R.
    Manzoli, L.
    Giuliani, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (05) : 523 - 529
  • [23] Diagnosing tuberculosis with urine lipoarabinomannan: systematic review and meta-analysis
    Minion, J.
    Leung, E.
    Talbot, E.
    Dheda, K.
    Pai, M.
    Menzies, D.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 38 (06) : 1398 - 1405
  • [24] Accuracy of the Most Common Provocation Tests for Diagnosing Carpal Tunnel Syndrome: A Systematic Review With Meta-analysis
    Nunez De Arenas-Arroyo, Sergio
    Cavero-Redondo, Ivan
    Torres-Costoso, Ana
    Reina-Gutierrez, Sara
    Jose Guzman-Pavon, Maria
    Martinez-Vizcaino, Vicente
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2022, 52 (08) : 522 - 531
  • [25] Diagnosing Suspected Scaphoid Fractures A Systematic Review and Meta-analysis
    Yin, Zhong-Gang
    Zhang, Jian-Bing
    Kan, Shi-Lian
    Wang, Xiao-Gang
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (03) : 723 - 734
  • [26] Accuracy of first-trimester ultrasound in diagnosis of tubal ectopic pregnancy in the absence of an obvious extrauterine embryo: systematic review and meta-analysis
    Richardson, A.
    Gallos, I.
    Dobson, S.
    Campbell, B. K.
    Coomarasamy, A.
    Raine-Fenning, N.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 47 (01) : 28 - 37
  • [27] Lytic Therapy for Retained Traumatic Hemothorax A Systematic Review and Meta-analysis
    Hendriksen, Brandon S.
    Kuroki, Marcos T.
    Armen, Scott B.
    Reed, Michael F.
    Taylor, Matthew D.
    Hollenbeak, Christopher S.
    CHEST, 2019, 155 (04) : 805 - 815
  • [28] Diagnostic accuracy of confocal scan in detecting acanthamoeba keratitis and fungal keratitis: a systematic review and meta-analysis
    Moshtaghion, Seyed Mohamadmehdi
    Abolhosseini, Mohammad
    Yaseri, Mehdi
    Hosseini, Seyed Bagher
    Kanavi, Mozhgan Rezaei
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (08) : 3011 - 3022
  • [29] Diagnostic accuracy of confocal scan in detecting acanthamoeba keratitis and fungal keratitis: a systematic review and meta-analysis
    Seyed Mohamadmehdi Moshtaghion
    Mohammad Abolhosseini
    Mehdi Yaseri
    Seyed Bagher Hosseini
    Mozhgan Rezaei Kanavi
    International Ophthalmology, 2023, 43 : 3011 - 3022
  • [30] Diagnostic Accuracy of Sonographic and Clinical Parameters in the Prediction of Retained Products of Conception
    Matijevic, Ratko
    Knezevic, Mario
    Grgic, Ozren
    Zlodi-Hrsak, Lana
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (03) : 295 - 299