Effective and organ doses in patient undergoing interventional neuroradiology procedures: A multicentre study

被引:0
|
作者
D'Alessio, Andrea [1 ]
Strocchi, Sabina [2 ]
Dalmasso, Federico [3 ]
Cannillo, Barbara [1 ]
Matheoud, Roberta [1 ]
Ponzetti, Alex [3 ,4 ]
Aimonetto, Stefania [3 ]
Cernigliaro, Massimiliano [5 ]
Azzalin, Giulia [5 ]
Giorgianni, Andrea [6 ]
Natrella, Massimiliano [7 ]
Carriero, Alessandro [5 ]
Guzzardi, Giuseppe [5 ]
Brambilla, Marco [1 ]
机构
[1] Univ Hosp Maggiore Carita, Med Phys Dept, Novara, Italy
[2] ASST Sette Laghi Osped Circolo & Fdn Macchi, Med Phys Dept, Varese, Italy
[3] AUSL Valle Aosta U Parini Reg Hosp, Med Phys Dept, Aosta, Italy
[4] Univ Turin, Med Phys Postgrad Sch, Turin, Italy
[5] Univ Hosp Maggiore Carita, Radiol Dept, Novara, Italy
[6] ASST Sette Laghi Osped Circolo & Fdn Macchi, Neuroradiol Dept, Varese, Italy
[7] AUSL Valle Aosta U PariniReg Hosp, Radiol Dept, Aosta, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 122卷
关键词
Interventional neuroradiology; Conversion factors; Dosimetry; Effective/organ dose; KERMA AREA PRODUCT; CONVERSION FACTORS; ANGIOGRAPHY; TECHNOLOGY; RADIOLOGY; DSA;
D O I
10.1016/j.ejmp.2024.103383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiation doses to adult patients submitted to cerebral angiography and intracranial aneurysms treatments were assessed by using DICOM Radiation Dose Structured Reports (RDSR) and Monte Carlo simulations. Conversion factors to estimate effective and organ doses from Kerma-Area Product (PKA) values were determined. Methods: 77 cerebral procedures performed with five angiographic equipment installed in three Italian centres were analyzed. Local settings and acquisition protocols were considered. The geometrical, technical and dosimetric data of 16,244 irradiation events (13305 fluoroscopy, 2811 digital subtraction angiography, 128 conebeam CT) were extracted from RDSRs by local dose monitoring systems and were input in MonteCarlo PCXMC software to calculate effective and organ doses. Finally, conversion factors to determine effective and organ doses from PKA were determined. Differences between centres were assessed through statistical analysis and accuracy of dose calculation method based on conversion factors was assessed through Bland-Altman analysi. Results: Large variations in PKA (14-561 Gycm2) and effective dose (1.2-73.5 mSv) were observed due to different degrees of complexity in the procedures and angiographic system technology. The most exposed organs were brain, salivary glands, oral mucosa, thyroid and skeleton. The study highlights the importance of recent technology in reducing patient exposure (about fourfold, even more in DSA). No statistically significant difference was observed in conversion factors between centres, except for some organs. A conversion factor of 0.09 +/- 0.02 mSv/Gycm2 was obtained for effective dose. Conclusions: Organ and effective doses were assessed for neuro-interventional procedures. Conversion factors for calculating effective and organ doses from PKA were provided.
引用
收藏
页数:8
相关论文
共 42 条
  • [1] Organ and effective doses detriment to paediatric patients undergoing multiple interventional cardiology procedures
    Ubeda, Carlos
    Vano, Eliseo
    Miranda, Patricia
    Figueroa, Ximena
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 182 - 187
  • [2] Adult patient doses in interventional neuroradiology
    Gkanatsios, NA
    Huda, W
    Peters, KR
    MEDICAL PHYSICS, 2002, 29 (05) : 717 - 723
  • [3] Reference levels and patient doses in interventional cardiology procedures in Greece
    Simantirakis, George
    Koukorava, Christina
    Kalathaki, Maria
    Pafilis, Christos
    Kaisas, Ioannis
    Economides, Sotirios
    Hourdakis, Costas J.
    Kamenopoulou, Vassiliki
    Georgiou, Evaggelos
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2324 - 2332
  • [4] Estimation of equivalent organ and effective doses to patients undergoing coronary angiography and percutaneous coronary intervention procedures using Monte Carlo simulation
    Ngaile, J. E.
    Msaki, P. K.
    Nyanda, P. B.
    Muhulo, A. P.
    Muhogora, W. E.
    Mvungi, R.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [5] Patient dose in angiographic interventional procedures: A multicentre study in Italy
    Isoardi, Paola
    D'Ercole, Loredana
    Cavallari, Monica
    Gianusso, Laura
    Pini, Silvia
    Giordano, Carlo
    Angelini, Lidia
    Colombo, Paola Enrica
    Delle Canne, Stefania
    Del Vecchio, Antonella
    Di Liberto, Riccardo
    Farnedi, Simona
    Ghetti, Caterina
    Lorenzini, Elena
    Origgi, Daniela
    Paruccini, Nicoletta
    Pasquino, Massimo
    Cutaia, Claudia
    Quattrocchi, Mariagrazia
    Riccardi, Lucia
    Soavi, Raffaella
    Strocchi, Sabina
    Trianni, Annalisa
    Venturi, Giovanna
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 273 - 292
  • [6] Patient radiation doses in paediatric interventional cardiology procedures: a review
    Harbron, R. W.
    Dreuil, S.
    Bernier, M-O
    Pearce, M. S.
    Thierry-Chef, I.
    Chapple, C-L
    Baysson, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : R131 - R144
  • [7] AN INVESTIGATION OF PATIENT DOSES DURING CORONARY INTERVENTIONAL PROCEDURES IN CHINA
    Cui, Yanhai
    Zhang, Hongdan
    Zheng, Junhui
    Yang, Xiangtai
    Liang, Changhong
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (03) : 296 - 302
  • [8] Local Reference Levels and Organ Doses From Pediatric Cardiac Interventional Procedures
    Barnaoui, S.
    Rehel, J. L.
    Baysson, H.
    Boudjemline, Y.
    Girodon, B.
    Bernier, M. O.
    Bonnet, D.
    Aubert, B.
    PEDIATRIC CARDIOLOGY, 2014, 35 (06) : 1037 - 1045
  • [9] Patient radiation exposure during diagnostic and therapeutic interventional neuroradiology procedures
    Alexander, M. D.
    Oliff, M. C.
    Olorunsola, O. G.
    Brus-Ramer, M.
    Nickoloff, E. L.
    Meyers, P. M.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2010, 2 (01) : 6 - 10
  • [10] Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France
    Etard, Cecile
    Bigand, Emeline
    Salvat, Cecile
    Vidal, Vincent
    Beregi, Jean Paul
    Hornbeck, Amaury
    Greffier, Joel
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4281 - 4290