Metrology of Supraspinatus Tendon Thickness in Swimmers with Tendinopathy Using Ultrasound Imaging: An Intra- and Inter-Rater Reliability Study

被引:1
作者
Klich, Sebastian [1 ]
Podczarska-Glowacka, Magdalena [2 ]
Valera-Calero, Juan Antonio [3 ,4 ]
Arias-Buria, Jose Luis [5 ]
Fernandez-de-Las-Penas, Cesar [5 ]
机构
[1] Wroclaw Univ Hlth & Sport Sci, Dept Paralymp Sport, Wroclaw PL-51612, Poland
[2] Gdansk Univ Phys Educ & Sport, Dept Basic Physiotherapy, PL-80336 Gdansk, Poland
[3] Univ Complutense Madrid, Fac Nursery Physiotherapy & Podiatry, Dept Radiol Rehabil & Physiotherapy, Madrid 28040, Spain
[4] Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Grp InPhysio, Madrid 28040, Spain
[5] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Phys Med & Rehab, Madrid 28922, Spain
关键词
B-mode; ultrasound; rotator cuff; tendinopathy; overhead movements; swimmers; ACROMIO-HUMERAL DISTANCE; TEST-RETEST RELIABILITY; IMPINGEMENT SYNDROME; SUBACROMIAL SPACE; SHOULDER; VOLUME; PAIN;
D O I
10.3390/jcm13133822
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed to assess the relative and absolute intra- and inter-rater reliability of supraspinatus tendon (SST) thickness. Materials: Thirty adolescent swimmers with supraspinatus (SS) tendinopathy (n = 15) and a control-matched group (n = 15) were evaluated. Tendon thickness was measured according to four different measure procedures, i.e., (1) at 15 mm, (2) at 10, 20, and 30 mm, (3) at 10, 15, and 20 mm, and (4) 5 and 10 mm lateral to the most hyperechogenic reference point of the biceps tendon. Each examiner took two US images for the test measurements with a 10 min rest period. After 30 min, the subjects underwent retest measurements that were also repeated 1 week later. Results: SST thickness was greater in swimmers with SS tendinopathy compared with the matched control group for each procedure and rater (p < 0.001). Intra- and inter-rater reliability was good to excellent (ICC2.3: 0.78-0.98 and 0.83-0.97, respectively) in both groups. The lowest intra- and inter-rater reliability was found in procedures no. 2 and 4 (ICC2.3: 0.78 and 0.83). However, procedure no. 3 was the most reliable with the lowest error rate (ICC2.3: 0.92-0.97; SEM: 0.05-0.10 mm; MDC: 0.14-0.28 mm). Conclusions: The study confirmed the diagnostic value of ultrasound in SS tendinopathy. A multiple-reference-point procedure including a simple methodology (10, 15, and 20 mm from biceps tendon), was defined as the most reliable, expressed by the highest intra- and inter-rater ICCs.
引用
收藏
页数:10
相关论文
共 31 条
  • [1] Ahmad Ashfaq, 2017, J Phys Ther Sci, V29, P1394, DOI 10.1589/jpts.29.1394
  • [2] Arifin WN., 2018, ED MED J, V10, DOI [10.21315/eimj2018.10.3.8, DOI 10.21315/EIMJ2018.10.3.8]
  • [3] Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acrnmiohumeral Distance, and Occupatiun Ratio in Patients With Shoulder Impingement Syndrome
    Bagcier, Fatih
    Kulcu, Duygu Geler
    Yorulmaz, Elem
    Altunok, Elif Cigdem
    [J]. ARCHIVES OF RHEUMATOLOGY, 2020, 35 (03) : 385 - 393
  • [4] Ultrasound measurement of rotator cuff thickness and acromio-humeral distance in the diagnosis of subacromial impingement syndrome of the shoulder
    Cholewinski, Jerzy J.
    Kusz, Damian J.
    Cielinski, Lukasz S.
    Zoladz, Miroslaw P.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (04) : 408 - 414
  • [5] Association Between Years of Competition and Shoulder Function in Collegiate Swimmers
    Dischler, Jack D.
    Baumer, Timothy G.
    Finkelstein, Evan
    Siegal, Daniel S.
    Bey, Michael J.
    [J]. SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2018, 10 (02): : 113 - 118
  • [6] Measurements of rotator cuff tendons, acromioclavicular joint space, and subacromion-subdeltoid bursa in the adults sudanese population using ultrasonography
    Elgyoum, Ala M. A.
    Mohammed, Marwa H.
    Abdelrahim, Ahmed
    Zidan, Mogahid M. A.
    Fagiry, Moram A.
    Salih, Mohammed
    Elhaj, Mona
    Davidson, Rob
    Mahmoud, Mustafa Z.
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2021, 14 (01) : 495 - 501
  • [7] Changes in shoulder outcomes using ultrasonographic assessment of breast cancer survivors: a prospective longitudinal study with 6-month follow-up
    Gala-Alarcon, Paula
    Prieto-Gomez, Virginia
    Bailon-Cerezo, Javier
    Jose Yuste-Sanchez, Maria
    Arranz-Martin, Beatriz
    Torres-Lacomba, Maria
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Supraspinatus tendon organizational and mechanical properties in a chronic rotator cuff tear animal model
    Gimbel, JA
    Van Kleunen, JP
    Mehta, S
    Perry, SM
    Williams, GR
    Soslowsky, LJ
    [J]. JOURNAL OF BIOMECHANICS, 2004, 37 (05) : 739 - 749
  • [9] Acromiohumeral distance and supraspinatus tendon thickness in people with shoulder impingement syndrome compared to asymptomatic age and gender-matched participants: a case control study
    Hunter, Donald J.
    Rivett, Darren A.
    McKiernan, Sharmaine
    Snodgrass, Suzanne J.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [10] Functional and morphological changes in shoulder girdle muscles after repeated climbing exercise
    Klich, Sebastian
    Madeleine, Pascal
    Ficek, Krzysztof
    Sommer, Klaudia
    Fernandez-de-Las-Penas, Cesar
    Michener, Lori A.
    Kawczynski, Adam
    [J]. RESEARCH IN SPORTS MEDICINE, 2023, 31 (06) : 787 - 801