The relation of lactate level and carbon dioxide pressure discrepancies between transcutaneous and arterial measurements

被引:0
|
作者
Gurun Kaya, Aslihan [1 ]
Ozpinar, Seyda Nur [1 ]
Oz, Mirac [1 ]
Erol, Serhat [1 ]
Arslan, Fatma [1 ]
Ciledag, Aydin [1 ]
Kaya, Akin [1 ]
机构
[1] Ankara Univ, Fac Med, Dept Chest Dis, Ankara, Turkiye
来源
TUBERKULOZ VE TORAKS-TUBERCULOSIS AND THORAX | 2024年 / 72卷 / 02期
关键词
Transcutaneous carbondioxide; lactate; arterial blood gases; hypercapnia; ACCURACY; MONITOR; OXYGEN;
D O I
10.5578/tt.202402920
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Partial carbondioxide pressure of the arterial blood (PaCO2) is used to evaluate alveolar ventilation. Transcutaneous carbon dioxide pressure (TcCO2) monitoring has been developed as a non-invasive (NIV) alternative to arterial blood gas analysis (ABG). Studies have shown that decreased tissue perfusion leads to increased carbondioxide (CO2). The use of transcutaneous capnometry may be unreliable in patients with perfusion abnormalities. In this study, we aimed to evaluate the relation between TcCO2-PaCO2 and lactate level which is recognized as a marker of hypoperfusion. Materials and Methods: In this prospective cohort study in critical care patients with hypercapnic respiratory failure (PaCO2 >= 45 mmHg) who received NIV between April 2019 and January 2020 in the intensive care unit were enrolled in the study. Patients' simultaneously measured TcCO2 and PaCO2 values of hypercapnic patients were recorded. Each paired measurement was categorized into two groups; normal lactate (<2 mmol/L) and increased lactate (>= 2 mmol/L). Results: A total of 116 paired TcCO2 and PaCO2 measurements of 29 patients were recorded. Bland -Altman analysis showed the mean bias between the TcCO2 and PaCO2 and 95% limits of agreement (LOA) in all measurements (1.75 mmHg 95% LOA -3.67 to 7.17); in the normal lactate group (0.66 mmHg 95% LOA -1.71 to 3.03); and in the increased lactate group (5.17 mmHg 95% LOA -1.63 to 11.97). The analysis showed a correlation between lactate level and the difference between TcCO2 and PaCO2 (r= 0.79, p< 0.001) and a negative correlation between mean blood pressure and the difference between TcCO2 and PaCO2 (r= -0.54, p= 0.001). Multiple regression analysis results showed that lactate level was independently associated with increased differences between TcCO2 and PaCO2 (Beta= 0.875, p< 0.001). Conclusion: TcCO2 monitoring may not be reliable in patients with increased lactate levels. TcCO2 levels should be checked by ABG analysis in these patients.
引用
收藏
页码:120 / 130
页数:11
相关论文
共 50 条
  • [1] Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED
    Delerme, Samuel
    Montout, Viviane
    Goulet, Helene
    Arhan, Amandine
    Le Sache, Frederic
    Devilliers, Catherine
    Riou, Bruno
    Ray, Patrick
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (09): : 1872 - 1876
  • [2] Variability of Transcutaneous Oxygen and Carbon Dioxide Pressure Measurements Associated with Sensor Location
    Gorska, K.
    Korczynski, P.
    Maskey-Warzechowska, M.
    Chazan, R.
    Krenke, R.
    PULMONARY FUNCTION, 2015, 858 : 39 - 46
  • [3] Arterial and transcutaneous variability and agreement between multiple successive measurements of carbon dioxide in patients with chronic obstructive lung disease
    Thomsen, Lars Pilegaard
    Faaborg, Thea Heide
    Rees, Stephen Edward
    Weinreich, Ulla Moller
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2020, 280
  • [4] Are Transcutaneous Oxygen and Carbon Dioxide Determinations of Value in Pulmonary Arterial Hypertension?
    Tonelli, Adriano R.
    Alkukhun, Laith
    Cikach, Frank
    Ahmed, Mostafa
    Dweik, Raed A.
    MICROCIRCULATION, 2015, 22 (04) : 249 - 256
  • [5] Transcutaneous carbon dioxide measurements. Dynamics during hyperventilation in healthy adults
    Bertram, L.
    Stiel, S.
    Groezinger, M.
    ANAESTHESIST, 2012, 61 (12): : 1027 - +
  • [6] The utility of transcutaneous carbon dioxide measurements in the emergency department: A prospective cohort study
    Barneck, Mitchell
    Papa, Linda
    Cozart, Ashley
    Lentine, Kain
    Ladde, Jay
    Nguyen, Linh
    Mayfield, Jeremy
    Thundiyil, Josef
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2021, 2 (04)
  • [7] Concordance and limits between transcutaneous and arterial carbon dioxide pressure in emergency department patients with acute respiratory failure: a single-center prospective observational study
    Bobbia, Xavier
    Claret, Pierre-Geraud
    Palmier, Ludovic
    Robert, Michael
    Grandpierre, Romain Genre
    Roger, Claire
    Ray, Patrick
    Sebbane, Mustapha
    Muller, Laurent
    de La Coussaye, Jean-Emmanuel
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2015, 23
  • [8] COMPARISON OF EAR AND CHEST PROBES IN TRANSCUTANEOUS CARBON DIOXIDE PRESSURE MEASUREMENTS DURING GENERAL ANESTHESIA IN ADULTS
    Nishiyama, Tomoki
    Kohno, Yumiko
    Koishi, Keiko
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2011, 25 (05) : 323 - 328
  • [9] A Wearable Device to Monitor the Partial Pressure of Transcutaneous Carbon Dioxide
    Angelucci, Alessandra
    Bernasconi, Sara
    Colombo, Luca
    Contini, Mauro
    Gugliandolo, Paola
    Agostoni, Piergiuseppe
    Aliverti, Andrea
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 12
  • [10] Comparison of Partial Pressure of Carbon Dioxide in Arterial Blood and Transcutaneous Carbon Dioxide Monitorizaiton in Patients with Obstructive Sleep Apnea and Sleep Related Hypoventilation/Hypoxemia Syndromes
    Beyan, Ayse Coskun
    Cirak, Ali Kadri
    Varol, Yelda
    Ucar, Zeynep Zeren
    JOURNAL OF TURKISH SLEEP MEDICINE-TURK UYKU TBB DERGISI, 2015, 2 (03): : 53 - 58