Determination of Luteolin and Apigenin in Herbal Teas by Online In-Tube Solid-Phase Microextraction Coupled with LC-MS/MS

被引:3
作者
Ishizaki, Atsushi [1 ]
Miura, Akiko [1 ]
Kataoka, Hiroyuki [1 ]
机构
[1] Shujitsu Univ, Sch Pharm, Nishigawara, Okayama 7038516, Japan
关键词
luteolin; apigenin; herbal teas; in-tube solid-phase microextraction; LC-MS/MS; online automated analysis; POTENTIAL HEALTH-BENEFITS; MASS-SPECTROMETRY; LIQUID; BIOACTIVITY; EXTRACTION; FLAVONOIDS; SAMPLES;
D O I
10.3390/foods13111687
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Herbal teas have attracted attention as functional beverages containing luteolin and apigenin, which exhibit antioxidant and anti-inflammatory effects. The objective of this study was to develop a sensitive online automated method to determine these flavones' contents in herbal teas using in-tube solid-phase microextraction (IT-SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). These compounds were extracted and concentrated by IT-SPME using a Supel Q PLOT capillary column and then separated and detected within 6 min using a CAPCELL PAK C18 MG III analytical column and a negative electrospray ionization-mode multiple-reaction monitoring system by LC-MS/MS. The detection limits (S/N = 3) for luteolin and apigenin were 0.4 and 0.8 pg mL-1, respectively, and the calibration curves were linear in the range of 2-2000 pg mL-1 with correlation coefficients above 0.9995, and intra-day and inter-day precisions with relative standard deviations below 2.9 and 3.6% (n = 6), respectively. The luteolin and apigenin in herbal tea were quantified using IT-SPME/LC-MS/MS following the acid hydrolysis of their glycosides. Among the 10 herbal teas tested, luteolin was detected in peppermint and sage at concentrations of 375 and 99 mu g mL-1, respectively, while apigenin was detected in German chamomile at 110 mu g mL-1, which were higher than in the other herbal teas. The method is expected to be a useful method for evaluating the efficacy of luteolin and apigenin in herbal teas as functional beverages.
引用
收藏
页数:12
相关论文
共 50 条
[21]   Simultaneous quantification of methylated purines in DNA by isotope dilution LC-MS/MS coupled with automated solid-phase extraction [J].
Hu, Chiung-Wen ;
Chen, Chih-Ming ;
Ho, Hsin Hui ;
Chao, Mu-Rong .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) :1199-1208
[22]   Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography [J].
Gonzalez-Fuenzalida, R. A. ;
Lopez-Garcia, E. ;
Moliner-Martinez, Y. ;
Campins-Falco, P. .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1432 :17-25
[23]   Comparison of different solid-phase extraction materials for the determination of fluoroquinolones in chicken plasma by LC-MS/MS [J].
Janusch, Franziska ;
Scherz, Gesine ;
Mohring, Siegrun A. I. ;
Stahl, Jessica ;
Hamscher, Gerd .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 951 :149-156
[24]   Simultaneous Determination of Twelve Sweeteners and Nine Preservatives in Foods by Solid-Phase Extraction and LC-MS/MS [J].
Tsuruda, Sayuri ;
Sakamoto, Tomonori ;
Akaki, Kouichi .
FOOD HYGIENE AND SAFETY SCIENCE, 2013, 54 (03) :204-212
[25]   Analysis of free and bound aroma compounds in grape berries using headspace solid-phase microextraction with GC-MS and a preliminary study of solid-phase extraction with LC-MS [J].
Prosen, Helena ;
Janes, Lucija ;
Strlic, Matija ;
Rusjan, Denis ;
Kocar, Drago .
ACTA CHIMICA SLOVENICA, 2007, 54 (01) :25-32
[26]   On-cartridge derivatization coupled with solid-phase extraction for the ultra-sensitive determination of minodronic acid in human plasma by LC-MS/MS method [J].
Yang, Yong ;
Liu, Cai ;
Zhang, Yifan ;
Zhou, Lei ;
Zhong, Dafang ;
Chen, Xiaoyan .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 114 :408-415
[27]   Automated determination of rifampicin in plasma samples by in-tube solid-phase microextraction coupled with liquid chromatography [J].
Melo, L. P. ;
Queiroz, R. H. C. ;
Queiroz, M. E. C. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (24) :2454-2458
[28]   Development and validation of a solid-phase extraction method coupled with LC-MS/MS for the simultaneous determination of 16 antibiotic residues in duck meat [J].
Zheng, Weijia ;
Abd El-Aty, A. M. ;
Kim, Seong-Kwan ;
Choi, Jeong-Min ;
Park, Da-Hee ;
Yoo, Kyung-Hee ;
Kang, Young-Sun ;
Jeon, Jong-Sup ;
Hacimuftuoglu, Ahmet ;
Shim, Jae-Han ;
Shin, Ho-Chul .
BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (05)
[29]   Molecularly imprinted solid-phase extraction coupled with LC-APCI-MS-MS for the selective determination of serum cholesterol [J].
Cordeiro Borges, Marcella Matos ;
de Oliveira, Hanna Leijoto ;
Borges, Keyller Bastos .
ELECTROPHORESIS, 2017, 38 (17) :2150-2159
[30]   Simultaneous determination of glyphosate, glufosinate and their metabolites in soybeans using solid-phase analytical derivatization and LC-MS/MS determination [J].
Sasano, Ryoichi ;
Sekizawa, Junpei ;
Saito, Isao ;
Harano, Mikihisa ;
Katsumoto, Kyoka ;
Ito, Rie ;
Iwasaki, Yusuke ;
Taguchi, Takaaki ;
Tsutsumi, Tomoaki ;
Akiyama, Hiroshi .
FOOD CHEMISTRY-X, 2024, 24