Novel high-efficiency 2D position-sensitive ZnS:Ag/6LiF scintillator detector for neutron diffraction

被引:2
|
作者
Mauri, Giacomo [1 ]
Sykora, G. Jeff [1 ]
Schooneveld, E. M. [1 ]
Capelli, S. C. [1 ]
Gutmann, M. J. [1 ]
Howarth, S. [1 ]
Mann, S. E. [1 ]
Zuddas, F. [1 ]
Rhodes, N. J. [1 ]
机构
[1] Sci & Technol Facil Council, Rutherford Appleton Lab, ISIS Neutron & Muon Source, Oxford OX11 0QX, England
来源
关键词
neutron detectors; neutron diffraction; scintillator detectors; SXD diffractometer; high efficiency; wavelength-shifting fibre detector; DIFFRACTOMETER;
D O I
10.1107/S1600576724002462
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Scintillator-based ZnS:Ag/(LiF)-Li-6 neutron detectors have been under development at ISIS for more than three decades. Continuous research and development aim to improve detector capabilities, achieve better performance and meet the increasingly demanding requirements set by neutron instruments. As part of this program, a high-efficiency 2D position-sensitive scintillator detector with wavelength-shifting fibres has been developed for neutron-diffraction applications. The detector consists of a double scintillator-fibre layer to improve detection efficiency. Each layer is made up of two orthogonal fibre planes placed between two ZnS:Ag/(LiF)-Li-6 scintillator screens. Thin reflective foils are attached to the front and back scintillators of each layer to minimize light cross-talk between layers. The detector has an active area of 192 x 192 mm with a square pixel size of 3 x 3 mm. As part of the development process of the double-layer detector, a single-layer detector was built, together with a prototype detector in which the two layers of the detector could be read out separately. Efficiency calculations and measurements of all three detectors are discussed. The novel double-layer detector has been installed and tested on the SXD diffractometer at ISIS. The detector performance is compared with the current scintillator detectors employed on SXD by studying reference crystal samples. More than a factor of 3 improvement in efficiency is achieved with the double-layer wavelength-shifting-fibre detector. Software routines for further optimizations in spatial resolution and uniformity of response have been implemented and tested for 2D detectors. The methods and results are discussed in this manuscript.
引用
收藏
页码:690 / 699
页数:10
相关论文
共 50 条
  • [31] Response linearization of a 2D optical position-sensitive detector
    Salles, Luciana P.
    Retes, Pedro
    Fernandes, Edilla M. G.
    de Lima Monteiro, Davies W.
    2007 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE, VOLS 1 AND 2, 2007, : 546 - 549
  • [32] Prototype of Position-Sensitive Scintillation Neutron Detector Based on SiPM and ZnS:Li6
    Glushkova, T. I.
    Trunov, D. N.
    Marin, V. N.
    Sadykov, R. A.
    Aksenov, S. N.
    JOURNAL OF SURFACE INVESTIGATION, 2023, 17 (01): : 130 - 134
  • [33] Selection of silicon photomultipliers for a (LiF)-Li-6:ZnS(Ag) scintillator based cold neutron detector
    Osovizky, A.
    Pritchard, K.
    Yehuda-Zada, Y.
    Ziegler, J. B.
    Tsai, P.
    Ghelman, M.
    Thompson, A. K.
    Ibberson, R. M.
    Baltic, G. M.
    Majkrzak, C. F.
    Maliszewskyj, N. C.
    JOURNAL OF PHYSICS COMMUNICATIONS, 2018, 2 (04):
  • [34] Prototype of Position-Sensitive Scintillation Neutron Detector Based on SiPM and ZnS:Li6
    T. I. Glushkova
    D. N. Trunov
    V. N. Marin
    R. A. Sadykov
    S. N. Aksenov
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2023, 17 : 130 - 134
  • [35] Performance of a Prototype Large Area Neutron Detector Based on 6LiF:ZnS(Ag) with MPPC Read-out
    Vacheret, A.
    Scovell, P. R.
    Haigh, M.
    Shitov, Yu.
    Waldron, A.
    Weber, A.
    Giudicelli, A.
    Fierfort, A.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [36] Developments of a 2D position sensitive neutron detector
    Tian Li-Chao
    Tang Bin
    Wang Xiao-Hu
    Liu Rong-Guang
    Zhang Jian
    Chen Yuan-Bo
    Sun Zhi-Jia
    Xu Hong
    Yang Gui-An
    Zhang Qiang
    CHINESE PHYSICS C, 2012, 36 (06) : 525 - 530
  • [37] Developments of a 2D position sensitive neutron detector
    田立朝
    唐彬
    王小胡
    刘荣光
    张建
    陈元柏
    孙志嘉
    徐虹
    杨桂安
    张强
    中国物理C, 2012, 36 (06) : 525 - 530
  • [38] Enhanced high-sensitivity multi-layer neutron detector based on LiF:ZnS(Ag) scintillator
    Zada, Ilan Cohen
    Osovizky, Alon
    Orion, Itzhak
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [39] ON THE USE OF A SMALL 2-DIMENSIONAL POSITION-SENSITIVE DETECTOR IN NEUTRON-DIFFRACTION
    LEHMANN, MS
    KUHS, WF
    MCINTYRE, GJ
    WILKINSON, C
    ALLIBON, JR
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1989, 22 : 562 - 568
  • [40] CONCEPT OF A NEW 2D POSITION-SENSITIVE SEMICONDUCTOR PIXEL DETECTOR
    WINKLER, W
    EHWALD, KE
    MEHR, W
    LANGE, W
    NOWAK, WD
    TRUTZSCHLER, K
    ECFA STUDY WEEK ON INSTRUMENTATION TECHNOLOGY FOR HIGH-LUMINOSITY HADRON COLLIDERS, PROCEEDINGS VOLS 1-2, 1989, 89 : 349 - 350