共 47 条
Differences Between Simulated Keratometry and Total Corneal Power in Eyes With Keratoconus and a Formula to Improve IOL Power Calculation Results
被引:1
|作者:
Coutinho, Catarina P.
[1
,2
]
Schiano-Lomoriello, Domenico
[3
]
Mazzotta, Cosimo
[4
,5
,6
]
Ferrise, Marco
[5
]
Hoffer, Kenneth J.
[7
,8
]
Ribeiro, Filomena J.
[9
,10
,11
]
Dias, Joao Mendanha
[2
]
Savini, Giacomo
[3
]
机构:
[1] Studio Oculist Azeglio, Piazza Galileo Galilei, I-40123 Bologna, Italy
[2] Univ Lisbon, GoLP, IPFN, Inst Super Tecn, Lisbon, Portugal
[3] IRCCS Bietti Fdn, Rome, Italy
[4] USL Toscana Sud Est, Dept Ophthalmol Unit, Campostaggia, Siena, Italy
[5] Siena Crosslinking Ctr, Monteriggioni, Siena, Italy
[6] Univ Siena, Post Grad Ophthalmol Sch, Siena, Italy
[7] St Marys Eye Ctr, Santa Monica, CA USA
[8] Stein Eye Inst, Los Angeles, CA USA
[9] Hosp Luz Lisboa, Lisbon, Portugal
[10] Lisbon Univ, Lisbon, Portugal
[11] Visual Sci Res Ctr, Lisbon, Portugal
关键词:
ACCURACY;
ERROR;
D O I:
10.3928/1081597X-20240311-06
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q -values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within +/- 0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes.
引用
收藏
页码:e253 / e259
页数:9
相关论文