Differences Between Simulated Keratometry and Total Corneal Power in Eyes With Keratoconus and a Formula to Improve IOL Power Calculation Results

被引:1
|
作者
Coutinho, Catarina P. [1 ,2 ]
Schiano-Lomoriello, Domenico [3 ]
Mazzotta, Cosimo [4 ,5 ,6 ]
Ferrise, Marco [5 ]
Hoffer, Kenneth J. [7 ,8 ]
Ribeiro, Filomena J. [9 ,10 ,11 ]
Dias, Joao Mendanha [2 ]
Savini, Giacomo [3 ]
机构
[1] Studio Oculist Azeglio, Piazza Galileo Galilei, I-40123 Bologna, Italy
[2] Univ Lisbon, GoLP, IPFN, Inst Super Tecn, Lisbon, Portugal
[3] IRCCS Bietti Fdn, Rome, Italy
[4] USL Toscana Sud Est, Dept Ophthalmol Unit, Campostaggia, Siena, Italy
[5] Siena Crosslinking Ctr, Monteriggioni, Siena, Italy
[6] Univ Siena, Post Grad Ophthalmol Sch, Siena, Italy
[7] St Marys Eye Ctr, Santa Monica, CA USA
[8] Stein Eye Inst, Los Angeles, CA USA
[9] Hosp Luz Lisboa, Lisbon, Portugal
[10] Lisbon Univ, Lisbon, Portugal
[11] Visual Sci Res Ctr, Lisbon, Portugal
关键词
ACCURACY; ERROR;
D O I
10.3928/1081597X-20240311-06
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q -values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within +/- 0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes.
引用
收藏
页码:e253 / e259
页数:9
相关论文
共 47 条
  • [1] Total keratometry versus standard keratometry for intraocular lens power calculation in eyes with keratoconus
    Parra-Bernal, Cinthya
    Villasenor-Garcia, Rocio
    Fernandez-Munoz, Erika
    Castro-Monreal, Miguel
    Gonzalez-Salinas, Roberto
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [2] Comparison of keratometry and corneal topography for calculation of power of IOL
    Tandon, S
    Egbert, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 908 - 908
  • [3] Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK
    Galzignato, Alice
    Galvis, Virgilio
    Tello, Alejandro
    Urrea, Juan F. F.
    Hoffer, Kenneth J. J.
    Coutinho, Catarina P. P.
    Schiano-Lomoriello, Domenico
    Savini, Giacomo
    PHOTONICS, 2023, 10 (06)
  • [4] Accuracy of IOL power calculation using total keratometry versus regular keratometry
    Reus, N. J.
    ACTA OPHTHALMOLOGICA, 2020, 98 : 31 - 31
  • [5] Prediction accuracy of IOL power calculation in patients with a large difference between conventional keratometry and total keratometry
    Hyon, Joon-Young
    Son, Yengwoo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [6] Comparison of Corneal Power Calculation by Standard Keratometry and Total Keratometry in Eyes With Previous Myopic FS-LASIK
    Lupardi, Enrico
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Schiano-Lomoriello, Domenico
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (12) : 848 - 852
  • [7] Corneal Asphericity and IOL Power Calculation in Eyes With Aspherical IOLs
    Savini, Giacomo
    Hoffer, Kenneth J.
    Barboni, Piero
    Lomoriello, Domenico Schiano
    Ducoli, Pietro
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (07) : 476 - 481
  • [8] Intraocular Lens Power Calculations in Keratoconus Eyes Comparing Keratometry, Total Keratometry, and Newer Formulae
    Heath, Michael T.
    Mulpuri, Lakshman
    Kimiagarov, Eden
    Patel, Raj P.
    Murphy, David A.
    Levine, Harry
    Tonk, Rahul S.
    Cooke, David L.
    Riaz, Kamran M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 206 - 214
  • [9] IOL Power Calculations in Post -Radial Keratotomy Eyes Comparing Formulas with Standard Keratometry and Total Keratometry
    Suraneni, Sanjana
    Anter, Abdelrahman M.
    Leal, Sebastien
    Bleeker, Adam
    Hoang, David
    Riaz, Kamran
    Cooke, David
    Tonk, Rahul S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [10] Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery
    Srivannaboon, Sabong
    Chirapapaisan, Chareenun
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (12) : 2677 - 2682