Comprehensive dosimetric commissioning of proton minibeam radiotherapy on a single gantry proton system

被引:0
作者
Lin, Yuting [1 ]
Li, Wangyao [1 ]
Wang, Aoxiang [1 ,2 ]
Johnson, Daniel [1 ]
Gan, Gregory N. [1 ]
Gao, Hao [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiat Oncol, Kansas City, KS 66103 USA
[2] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2024年 / 14卷
关键词
proton therapy; spatially fractionated radiotherapy; proton mini-beam; small field dosimetry; film dosimetry; proton dosimetry; FRACTIONATED RADIATION-THERAPY;
D O I
10.3389/fonc.2024.1421869
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Proton minibeam radiation therapy (pMBRT) can deliver spatially fractionated dose distributions with submillimeter resolution. These dose distributions exhibit significant heterogeneity in both depth and lateral directions. Accurate characterization of pMBRT doses requires dosimetry devices with high spatial resolution and a wide dynamic range. Furthermore, the dependency of dosimetric measurements on Linear Energy Transfer (LET), as observed in conventional proton therapy, is also present in pMBRT depth dose measurements.Purpose This work demonstrates the process of performing comprehensive dosimetric measurements to characterize the pMBRT collimator on a clinical single-gantry proton machine, utilizing commercially available dosimetry devices.Methods The minibeam collimator is designed to be mounted on the clinical nozzle as a beam-modifying accessory. Three collimators, each with a slit opening of 0.4 mm, are thoroughly evaluated. The center-to-center (c-t-c) distances of the slits for these collimators are 2.8 mm, 3.2 mm, and 4.0 mm, respectively. High spatial resolution dosimetry devices are essential for PMBRT dose characterizations. To meet this requirement, two-dimensional (2D) dose measurement devices, Gafchromic films, are used to measure lateral profiles at various depths. Films are also used for depth dose profile measurements in solid water. Additionally, high-resolution point dose detectors, microDiamond, and Razor diode detectors are employed for lateral profile measurements at various depths. Percent depth dose (PDD) measurements of pMBRT in solid water, with various proton energies, collimators, and air gaps, are performed using Gafchromic films. The film's LET dependency for proton beams is corrected to ensure accurate pMBRT PDD measurements. The Monte Carlo simulation tool TOPAS is utilized to compare and validate all experimental measurements.Results At depths where LET is not a concern, film dose measurements were consistent with microDiamond and Razor diode point measurements. The point detectors need to be orientated with the thin side aligned to the incoming beam. Comparison of the lateral dose profiles extracted from TOPAS simulations, films, microDiamond, and Razor diode detectors shows a passing rate exceeding 98% in 1D gamma analysis at 3% 0.1 mm criteria.However, when the microDiamond detector is orientated to face the pMBRT beam, its spatial resolution may not be sufficient to capture the peak and valley dose accurately. Nevertheless, an accuracy within 2% can still be achieved when comparing the average dose. The PDD measurements show that the peak valley dose ratio (PVDR) of pMBRT can be altered at different depths with different air gaps using the same collimator or different collimators of different c-t-c distances.Conclusion Our study demonstrates that comprehensive dose measurements for pMBRT can be conducted using standard clinical dose measurement devices. These measurements are indispensable for guiding and ensuring accurate dose reporting in pre-clinical studies using the pMBRT technique.
引用
收藏
页数:12
相关论文
共 39 条
  • [21] Full report of AAPM Task Group 235 radiochromic film dosimetry: An update to TG-55
    Niroomand-Rad, Azam
    Chiu-Tsao, Sou-Tung
    Grams, Michael P.
    Lewis, David F.
    Soares, Christopher G.
    Van Battum, Leo J.
    Das, Indra J.
    Trichter, Samuel
    Kissick, Michael W.
    Massillon-JL, Guerda
    Alvarez, Paola E.
    Chan, Maria F.
    [J]. MEDICAL PHYSICS, 2020, 47 (12) : 5986 - 6025
  • [22] Proton minibeam radiation therapy for treating metastases: A treatment plan study
    Ortiz, Ramon
    Belshi, Rezart
    De Marzi, Ludovic
    Prezado, Yolanda
    [J]. MEDICAL PHYSICS, 2023, 50 (04) : 2463 - 2473
  • [23] Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
    Ortiz, Ramon
    De Marzi, Ludovic
    Prezado, Yolanda
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5551 - 5561
  • [24] Paganetti H, 2018, Proton therapy physics
  • [25] TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
    Perl, J.
    Shin, J.
    Schuemann, J.
    Faddegon, B.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 6818 - 6837
  • [26] Proton minibeam radiation therapy: Experimental dosimetry evaluation
    Peucelle, C.
    Nauraye, C.
    Patriarca, A.
    Hierso, E.
    Fournier-Bidoz, N.
    Martinez-Rovira, I.
    Prezado, Y.
    [J]. MEDICAL PHYSICS, 2015, 42 (12) : 7108 - 7113
  • [27] Proton-minibeam radiation therapy: A proof of concept
    Prezado, Y.
    Fois, G. R.
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [28] Divide and conquer: spatially fractionated radiation therapy
    Prezado, Yolanda
    [J]. EXPERT REVIEWS IN MOLECULAR MEDICINE, 2022, 24
  • [29] Tumor Control in RG2 Glioma-Bearing Rats: A Comparison Between Proton Minibeam Therapy and Standard Proton Therapy
    Prezado, Yolanda
    Jouvion, Gregory
    Guardiola, Consuelo
    Gonzalez, Wilfredo
    Juchaux, Marjorie
    Bergs, Judith
    Nauraye, Catherine
    Labiod, Dalila
    De Marzi, Ludovic
    Pouzoulet, Frederic
    Patriarca, Annalisa
    Dendale, Remi
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (02): : 266 - 271
  • [30] Proton minibeam radiation therapy widens the therapeutic index for high-grade gliomas
    Prezado, Yolanda
    Jouvion, Gregory
    Patriarca, Annalisa
    Nauraye, Catherine
    Guardiola, Consuelo
    Juchaux, Marjorie
    Lamirault, Charlotte
    Labiod, Dalila
    Jourdain, Laurene
    Sebrie, Catherine
    Dendale, Remi
    Gonzalez, Wilfredo
    Pouzoulet, Frederic
    [J]. SCIENTIFIC REPORTS, 2018, 8