Air bubble guide for adequacy of ophthalmic viscosurgical device during phacoemulsification

被引:0
作者
Nath, Manas [1 ]
Odayappan, Annamalai [3 ,5 ]
Tripathy, Koushik [2 ]
Nachiappan, Sivagami [4 ]
机构
[1] ASG Eye Hosp, Glaucoma & Refract Serv, Cataract, Kolkata, W Bengal, India
[2] ASG Eye Hosp, Vitreo Retina & Uvea Serv, Kolkata, W Bengal, India
[3] Aravind Eye Hosp, Glaucoma Serv, Pondicherry, India
[4] Aravind Eye Hosp, Pediat Ophthalmol, Pondicherry, India
[5] Univ Michigan, Kellogg Eye Ctr, Ann Arbor, MI 48109 USA
关键词
Air bubble; ophthalmic viscosurgical device; phacoemulsification; viscoelastics; NUCLEUS;
D O I
10.4103/IJO.IJO_2998_23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Phacoemulsification in hard cataracts is a challenge. The use of dispersive ophthalmic viscosurgical devices (OVDs) to protect the endothelium is a routine step in such scenarios. However, as OVD is transparent, it is difficult to spot within the anterior chamber. Therefore, surgeons may not be aware when the OVD coating of the endothelium disappears during surgery. Consequently, there may be too frequent OVD injections, resulting in a waste of resources. On the contrary, the surgeon may fail to inject OVD at an appropriate time, leading to greater endothelial damage. We propose a novel technique of using an air bubble as a guide that helps in identifying the time when OVD disappears from the anterior chamber, thereby suggesting the surgeon to reinject before proceeding further.
引用
收藏
页码:916 / 918
页数:3
相关论文
共 38 条
  • [31] Descemet Membrane Detachment After Phacoemulsification Surgery: Risk Factors and Success of Air Bubble Tamponade
    Ti, Seng-Ei
    Chee, Soon-Phaik
    Tan, Donald T. H.
    Yang, You-Nian
    Shuang, Stephanie L.
    CORNEA, 2013, 32 (04) : 454 - 459
  • [32] One-year Observation of Safety of Implantable Collamer Lens V4c Implantation Without Using an Ophthalmic Viscosurgical Device
    Chen, Zhuoyi
    Niu, Lingling
    Zhao, Jing
    Yao, Peijun
    Wang, Xiaoying
    Zhou, Xingtao
    FRONTIERS IN MEDICINE, 2022, 9
  • [33] Testing a Novel Device for Accurate Ultrasound Delivery During Crystalline Lens Phacoemulsification Surgery
    Rossi, Tommaso
    Saffioti, Stefano
    Angelini, Giampiero
    Querzoli, Giorgio
    Telanil, Serena
    Rossi, Alessandro
    Ripandelli, Guido
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (03):
  • [34] Air bubble entrapment during drop impact on solid and liquid surfaces
    Halder, Subhayan
    Granda, Rafael
    Wu, Jingwei
    Sankaran, Abhilash
    Yurkiv, Vitaliy
    Yarin, Alexander L.
    Mashayek, Farzad
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2022, 149
  • [35] Experimental investigation on air bubble dynamics during fine powder discharge in a silo
    Sheng, Li-Tsung
    Hsiau, Shu-San
    Wen, Chun-Yu
    ADVANCED POWDER TECHNOLOGY, 2021, 32 (01) : 106 - 120
  • [36] Evaluation of a new method of irrigation and aspiration for removal of ophthalmic viscoelastic device during cataract surgery in a porcine model
    Mitani, Arisa
    Suzuki, Takashi
    Tasaka, Yoshitaka
    Uda, Takahiro
    Hiramatsu, Yukako
    Kawasaki, Shiro
    Ohashi, Yuichi
    BMC OPHTHALMOLOGY, 2014, 14
  • [37] Kinetics of size change in air bubble and fat globule during ice cream freezing process
    Masuda, Hayato
    Sawano, Momoko
    Iyota, Hiroyuki
    Shimoyamada, Makoto
    JOURNAL OF FOOD PROCESS ENGINEERING, 2023, 46 (09)
  • [38] PROTECTIVE EFFECTS OF HEALON AND OCCUCOAT AGAINST AIR BUBBLE ENDOTHELIAL DAMAGE DURING ULTRASONIC AGITATION OF THE ANTERIOR-CHAMBER
    MONSON, MC
    TAMURA, M
    MAMALIS, N
    OLSON, RJ
    OLSON, RJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (05) : 613 - 616