Air bubble guide for adequacy of ophthalmic viscosurgical device during phacoemulsification

被引:0
|
作者
Nath, Manas [1 ]
Odayappan, Annamalai [3 ,5 ]
Tripathy, Koushik [2 ]
Nachiappan, Sivagami [4 ]
机构
[1] ASG Eye Hosp, Glaucoma & Refract Serv, Cataract, Kolkata, W Bengal, India
[2] ASG Eye Hosp, Vitreo Retina & Uvea Serv, Kolkata, W Bengal, India
[3] Aravind Eye Hosp, Glaucoma Serv, Pondicherry, India
[4] Aravind Eye Hosp, Pediat Ophthalmol, Pondicherry, India
[5] Univ Michigan, Kellogg Eye Ctr, Ann Arbor, MI 48109 USA
关键词
Air bubble; ophthalmic viscosurgical device; phacoemulsification; viscoelastics; NUCLEUS;
D O I
10.4103/IJO.IJO_2998_23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Phacoemulsification in hard cataracts is a challenge. The use of dispersive ophthalmic viscosurgical devices (OVDs) to protect the endothelium is a routine step in such scenarios. However, as OVD is transparent, it is difficult to spot within the anterior chamber. Therefore, surgeons may not be aware when the OVD coating of the endothelium disappears during surgery. Consequently, there may be too frequent OVD injections, resulting in a waste of resources. On the contrary, the surgeon may fail to inject OVD at an appropriate time, leading to greater endothelial damage. We propose a novel technique of using an air bubble as a guide that helps in identifying the time when OVD disappears from the anterior chamber, thereby suggesting the surgeon to reinject before proceeding further.
引用
收藏
页码:916 / 918
页数:3
相关论文
共 50 条
  • [1] In vitro behavior of ophthalmic viscosurgical devices during phacoemulsification
    Bissen-Miyajima, Hiroko
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06): : 1026 - 1031
  • [2] Thermal Burns Caused by Ophthalmic Viscosurgical Device Occlusion in Torsional Phacoemulsification
    Lee, Yuan-Chieh
    TZU CHI MEDICAL JOURNAL, 2010, 22 (04): : 229 - 231
  • [3] Retained ophthalmic viscosurgical device material in the capsular bag 6 months after phacoemulsification
    Sholohov, G
    Levartovsky, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03): : 627 - 629
  • [4] The safety and efficacy of phacoemulsification surgery in uncomplicated cataracts with and without an ophthalmic-viscosurgical-device
    Akmaz, Berkay
    Kilic, Deniz
    Duru, Necati
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 269 - 277
  • [5] Corneal endothelial cell coating during phacoemulsification using a new dispersive hyaluronic acid ophthalmic viscosurgical device
    Kretz, Florian T. A.
    Limberger, I-Joo
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1879 - 1884
  • [6] Pure phaco: phacoemulsification without ophthalmic viscosurgical devices
    Bardoloi, Narayan
    Sarkar, Sandip
    Pilania, Ashu
    Das, Himangshu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 174 - 178
  • [7] Efficacy of Ophthalmic Viscosurgical Devices in Preventing Temperature Rise at the Corneal Endothelium during Phacoemulsification
    Suzuki, Hisaharu
    Igarashi, Tsutomu
    Shiwa, Toshihiko
    Takahashi, Hiroshi
    CURRENT EYE RESEARCH, 2016, 41 (12) : 1548 - 1552
  • [8] Transient, complete loss of vision secondary to posterior diffusion of an ophthalmic viscosurgical device-lidocaine solution during complicated phacoemulsification
    Falzon, Kevin
    Guerin, Marc B.
    Fulcher, Tim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08): : 1472 - 1473
  • [9] Corneal endothelial damage in phacoemulsification using an anterior chamber maintainer compared with using an ophthalmic viscosurgical device
    Mayali, Huseyin
    Baser, Esin Fatma
    Kurt, Emin
    Ilker, Suleyman Sami
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 612 - 617
  • [10] Alteration of free radical development by ophthalmic viscosurgical devices in phacoemulsification
    Takahashi, Hiroshi
    Suzuki, Hisaharu
    Shiwa, Toshihiko
    Sakamoto, Atsuhiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09): : 1545 - 1548