CFD Analysis of Concentric Tube in Tube Latent Heat Thermal Energy Storage Unit

被引:0
作者
Shrivastava, Amit [1 ]
Kumar, Manvendra [1 ]
Kumar, Dileep [1 ]
Chakraborty, Prodyut R. [1 ]
机构
[1] IIT Jodhpur, Dept Mech Engn, Jodhpur 342037, Rajasthan, India
来源
PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019 | 2019年
关键词
LHTES; volume fraction updating technique; melting; solidification; charging; discharging; compressed expanded graphite; CEG; PCM-CEG composite; PHASE-CHANGE; ANALYTICAL-MODEL; MELTING PROCESS; PCM; SOLIDIFICATION;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present work, performance of a single concentric Tube in tube latent heat storage unit is analysed. A 2-D axisymmetric analysis is performed using ANSYS-FLUENT platform. Cycle dynamics of the latent heat thermal energy storage (LHTES) is studied during charging and discharging process considering laminar and turbulent flow of the heat transfer fluid (HTF). Solar salt, a binary eutectic mixture, (60% NaNO3-40% KNO3) is used as PCM, which behaves as a pure substance. Therminol vp1 is considered as HTF. The analysis deals with pure PCM as well as PCM-Graphite composite (cPCM) with enhanced thermal conductivity. In the PCM domain, energy conservation equation is considered to be diffusion dominated. The melt volume fraction is estimated by using volume fraction updating scheme. The geometry consists of a central pipe (with finite pipe wall thickness) carrying HTF and a thick annular region surrounding the pipe represents PCM or cPCM domain. Convection in the PCM melt is completely neglected. For ANSYS Fluent simulation, a separate user defined scalar (UDS) code in C++ language is developed for solving energy equation, volume fraction update, anisotropic conductivity of PCM, velocity profile and source terms, and are incorporated to ANSYS Fluent solver consequently through user defined function (UDF). Default energy equation and solidification and melting models in the model section of ANSYS Fluent are switched off for their inherent limitations.
引用
收藏
页数:6
相关论文
共 13 条
[11]   Numerical investigation of PCM melting process in sleeve tube with internal fins [J].
Wang, Peilun ;
Yao, Hua ;
Lan, Zhipeng ;
Peng, Zhijian ;
Huang, Yun ;
Ding, Yulong .
ENERGY CONVERSION AND MANAGEMENT, 2016, 110 :428-435
[12]   Thermal energy storage and retrieval characteristics of a molten-salt latent heat thermal energy storage system [J].
Zhang, P. ;
Ma, F. ;
Xiao, X. .
APPLIED ENERGY, 2016, 173 :255-271
[13]   Semi-analytical solution of thermal energy storage system with conjugate laminar forced convection [J].
Zhang, YW ;
Faghri, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (04) :717-724