Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma

被引:0
|
作者
Ficke, Jennifer B. [1 ]
Watson, Nora L. [2 ]
Stocker, Derek J. [1 ]
Schlegel, Kevin E. [1 ]
Sahajwalla, Maya C. [1 ]
Adams, Chad C. [3 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Dept Radiol, Bethesda, MD 20814 USA
[2] Walter Reed Natl Mil Med Ctr, Dept Res Programs, Bethesda, MD USA
[3] Eisenhower Army Med Ctr, Dept Radiol, Augusta, GA USA
关键词
SPECT/CT; FASpecT; parathyroid adenoma; RECONSTRUCTION ALGORITHMS; LOCALIZATION; SCINTIGRAPHY; QUALITY;
D O I
10.2967/jnmt.122.264649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new SPECT/CT protocol for parathyroid imaging detailing fewer image -angle acquisitions (fewer -angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60 -stop protocol and the tested 15 -stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen K . Interrater reliability among the 3 readers was described for each method using the Fleiss K interpreted as in the strength -ofagreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic -quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction. ize surgical localization ble nonpathologic SPECT/CT added diagnosis planar nation ciency, patient 10 delayed clinics delayed lar will compared approximately
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [31] Increased sensitivity and confidence of SPECT over planar imaging in dual-phase sestamibi for parathyroid adenoma detection
    Slater, A
    Gleeson, FV
    CLINICAL NUCLEAR MEDICINE, 2005, 30 (01) : 1 - 3
  • [32] Parathyroid Adenoma Detected in 68Ga-PSMA PET/CT but Not in the Dedicated Imaging Modalities
    Cieslewicz, Maja
    Andryszak, Natalia
    Pelka, Kacper
    Szczepanek-Parulska, Ewelina
    Ruchala, Marek
    Kunikowska, Jolanta
    Czepczynski, Rafal
    DIAGNOSTICS, 2024, 14 (15)
  • [33] Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia
    Oeksuez, Mehmet Oezer
    Dittmann, Helmut
    Wicke, Corinna
    Muessig, Karsten
    Bares, Roland
    Pfannenberg, Christina
    Eschmann, Susanne Martina
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (04): : 297 - 307
  • [34] Preoperative 11C-Methionine PET/CT Enables Focussed Parathyroidectomy in MIBI-SPECT Negative Parathyroid Adenoma
    Christina Lenschow
    Peter Gassmann
    Christian Wenning
    Norbert Senninger
    Mario Colombo-Benkmann
    World Journal of Surgery, 2015, 39 : 1750 - 1757
  • [35] Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism
    Patel, C. N.
    Salahudeen, H. M.
    Lansdown, M.
    Scarsbrook, A. F.
    CLINICAL RADIOLOGY, 2010, 65 (04) : 278 - 287
  • [36] Preoperative 11C-Methionine PET/CT Enables Focussed Parathyroidectomy in MIBI-SPECT Negative Parathyroid Adenoma
    Lenschow, Christina
    Gassmann, Peter
    Wenning, Christian
    Senninger, Norbert
    Colombo-Benkmann, Mario
    WORLD JOURNAL OF SURGERY, 2015, 39 (07) : 1750 - 1757
  • [37] Diagnostic Value of Ultrasound and Tc-99m MIBI scintigraphy and SPECT/CT for Pre-operative Localization of Parathyroid Adenoma in Patients with Primary Hyperparathyroidism: A Single-Center Comparative Study
    Colakoglu, Bulent
    Alis, Deniz
    JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2019, 9 (03): : 115 - 120
  • [38] Optimization of 99mTc-sestamibi/123I subtraction SPECT/CT protocol for parathyroid scintigraphy
    Tunninen, V.
    Kauppinen, T.
    Eskola, H.
    EMBEC & NBC 2017, 2018, 65 : 847 - 851
  • [39] Effect of reconstruction algorithms on the accuracy of Tc-99m sestamibi SPECT/CT parathyroid imaging
    Nichols, Kenneth J.
    Tronco, Gene G.
    Palestro, Christopher J.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 5 (02): : 195 - 203
  • [40] Solitary Parathyroid Adenoma Localization in Technetium Tc99m Sestamibi SPECT and Multiphase Multidetector 4D CT
    Vu, T. H.
    Schellingerhout, D.
    Guha-Thakurta, N.
    Sun, J.
    Wei, W.
    Kappadth, S. C.
    Perrier, N.
    Kim, E. E.
    Rohren, E.
    Chuang, H. H.
    Wong, F. C.