Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma

被引:0
|
作者
Ficke, Jennifer B. [1 ]
Watson, Nora L. [2 ]
Stocker, Derek J. [1 ]
Schlegel, Kevin E. [1 ]
Sahajwalla, Maya C. [1 ]
Adams, Chad C. [3 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Dept Radiol, Bethesda, MD 20814 USA
[2] Walter Reed Natl Mil Med Ctr, Dept Res Programs, Bethesda, MD USA
[3] Eisenhower Army Med Ctr, Dept Radiol, Augusta, GA USA
关键词
SPECT/CT; FASpecT; parathyroid adenoma; RECONSTRUCTION ALGORITHMS; LOCALIZATION; SCINTIGRAPHY; QUALITY;
D O I
10.2967/jnmt.122.264649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new SPECT/CT protocol for parathyroid imaging detailing fewer image -angle acquisitions (fewer -angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60 -stop protocol and the tested 15 -stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen K . Interrater reliability among the 3 readers was described for each method using the Fleiss K interpreted as in the strength -ofagreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic -quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction. ize surgical localization ble nonpathologic SPECT/CT added diagnosis planar nation ciency, patient 10 delayed clinics delayed lar will compared approximately
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [21] A rare case of double parathyroid adenoma evidenced by 99mTc-sestaMIBI SPECT/CT
    Martinez-Valle Torres, M. D.
    Ramos Moreno, E.
    Amrani Raissouni, T.
    Sanz Viedma, S.
    Delgado Garcia, A.
    Jimenez-Hoyuela Garcia, J. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2017, 36 (01): : 57 - 58
  • [22] Direct Comparison of Neck Pinhole Dual-Tracer and Dual-Phase MIBI Accuracies With and Without SPECT/CT for Parathyroid Adenoma Detection and Localization
    Heiba, Sherif I.
    Jiang, Manli
    Rivera, Javier
    Genden, Eric
    Inabnet, William, III
    Machac, Josef
    Kostakoglu, Lale
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (06) : 476 - 482
  • [23] Value of 99mTc-MIBI SPECT/CT parathyroid imaging and ultrasonography for concomitant thyroid carcinoma
    Guo, Rui
    Wang, Jiqiu
    Zhang, Min
    Zhang, Miao
    Meng, Hongping
    Zhang, Yifan
    Li, Biao
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (08) : 676 - 682
  • [24] Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase 99mTc-Sestamibi parathyroid scintigraphy
    Lavely, William C.
    Goetze, Sibyll
    Friedman, Kent P.
    Leal, Jeffrey P.
    Zhang, Zhe
    Garret-Mayer, Elizabeth
    Dackiw, Alan P.
    Tufano, Ralph P.
    Zeiger, Martha A.
    Ziessman, Harvey A.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1084 - 1089
  • [25] Atypical non-[99mTc]Tc-MIBI avid parathyroid adenoma with a sternal brown tumor, mimicking ectopic parathyroid adenoma in planar and SPECT images: Importance of SPECT/CT acquisition
    Roustaei, Hessamoddin
    Yaghoubi, Mohammad Ali
    Golestani, Zahra Bakhshi
    Sadrizadeh, Ali
    Sadeghi, Ramin
    Barashki, Somayeh
    Aghaee, Atena
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2022, 30 (01): : 76 - 79
  • [26] Analysis of intraoperative laboratory measurements and imaging techniques such as Tc-99 m-MIBI SPECT/CT, 18F-fluorocholine PET/CT and ultrasound in patients operated with prediagnosis of parathyroid adenoma
    Nurullah Bilen
    Mehmet Avni Gokalp
    Latif Yilmaz
    Alper Aytekin
    Ilyas Baskonus
    Irish Journal of Medical Science (1971 -), 2023, 192 : 1695 - 1702
  • [27] Analysis of intraoperative laboratory measurements and imaging techniques such as Tc-99 m-MIBI SPECT/CT, 18F-fluorocholine PET/CT and ultrasound in patients operated with prediagnosis of parathyroid adenoma
    Bilen, Nurullah
    Gokalp, Mehmet Avni
    Yilmaz, Latif
    Aytekin, Alper
    Baskonus, Ilyas
    IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (04) : 1695 - 1702
  • [28] Comparison of single photon emission CT (SPECT) with SPECT/CT imaging in preoperative localization of parathyroid adenomas: A cost-effectiveness analysis
    Barber, Brittany
    Moher, Conrad
    Cote, David
    Fung, Elaine
    O'Connell, Daniel
    Dziegielewski, Peter
    Harris, Jeffrey
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 : E2062 - E2065
  • [29] A Digital Platform for Simulating the Accurate Detectability of Overactive Parathyroid Glands in SPECT/CT Imaging
    Oral, Aysegul
    Guvenis, Albert
    2019 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO), 2019, : 244 - 247
  • [30] Papillary Thyroid Cancer, Small Cell Lung Cancer, and Parathyroid Adenoma Synchronously Visualized on 99mTc-MIBI SPECT/CT in a Patient With Hyperparathyroidism Comparison With 18F-FDG PET/CT
    Chun, In Kook
    Lee, Seungkoo
    CLINICAL NUCLEAR MEDICINE, 2024, 49 (08) : 774 - 776