Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma

被引:0
|
作者
Ficke, Jennifer B. [1 ]
Watson, Nora L. [2 ]
Stocker, Derek J. [1 ]
Schlegel, Kevin E. [1 ]
Sahajwalla, Maya C. [1 ]
Adams, Chad C. [3 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Dept Radiol, Bethesda, MD 20814 USA
[2] Walter Reed Natl Mil Med Ctr, Dept Res Programs, Bethesda, MD USA
[3] Eisenhower Army Med Ctr, Dept Radiol, Augusta, GA USA
关键词
SPECT/CT; FASpecT; parathyroid adenoma; RECONSTRUCTION ALGORITHMS; LOCALIZATION; SCINTIGRAPHY; QUALITY;
D O I
10.2967/jnmt.122.264649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new SPECT/CT protocol for parathyroid imaging detailing fewer image -angle acquisitions (fewer -angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60 -stop protocol and the tested 15 -stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen K . Interrater reliability among the 3 readers was described for each method using the Fleiss K interpreted as in the strength -ofagreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic -quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction. ize surgical localization ble nonpathologic SPECT/CT added diagnosis planar nation ciency, patient 10 delayed clinics delayed lar will compared approximately
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [1] Fewer-Angle SPECT/CT Blood Pool Imaging for Infection and Inflammation
    Phillips, William T.
    Gorzell, Brandon C.
    Martinez, Robert A.
    Salman, Umber A.
    Cooper, Albert W.
    Stocker, Derek J.
    Adams, Chad C.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2021, 49 (01) : 39 - 43
  • [2] Impact of hybrid SPECT/CT imaging on the detection of single parathyroid adenoma
    Morrison, Antony
    Brennan, Patrick C.
    Reed, Warren
    Pietrzyk, Mariusz
    Schembri, Geoff
    Bailey, Elizabeth
    Roach, Paul
    Evanoff, Michael
    Kench, Peter L.
    MEDICAL IMAGING 2011: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2011, 7966
  • [3] Added value of ultrasonography and Tc-99m MIBI SPECT/CT combined protocol in preoperative evaluation of parathyroid adenoma
    Tawfik, Ahmed Ibrahim
    Kamr, Wael Hamza
    Mahmoud, Walaa
    Shady, Islam Ahmed Abo
    Mohamed, Mohamed Hosny
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 336 - 342
  • [4] SPECT and subtraction imaging of an ectopic parathyroid adenoma
    Serchuk, LS
    Tomas, MB
    Patel, M
    Palestro, CJ
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (07) : 459 - 462
  • [5] SPECT/CT-Guided Ultrasound for Parathyroid Adenoma Localization: A 1-Stop Approach
    Touska, Philip
    Elstob, Alison
    Rao, Nikhil
    Parthipun, Arum
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2019, 47 (01) : 64 - 69
  • [6] SPECT-CT in the localization of an ectopic retropharyngeal parathyroid adenoma as a cause for persistent primary hyperparathyroidism
    Garcia-Talavera, P.
    Gonzalez, M. L.
    Ais, G.
    Olmos, R.
    Ruiz, M. A.
    Sainz, A.
    Gamazo, C.
    Gomez, A.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2012, 31 (05): : 275 - 277
  • [7] How hybrid SPECT/CT systems changed imaging work-up in detecting parathyroid adenoma (PA)
    Domenico Rubello
    Anna Margherita Maffione
    Endocrine, 2015, 48 : 1018 - 1019
  • [8] Parathyroid adenoma localization with 99mTc-sestamibi SPECT/CT: a meta-analysis
    Wong, Ka Kit
    Fig, Lorraine M.
    Gross, Milton D.
    Dwamena, Ben A.
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (04) : 363 - 375
  • [9] SPECT/CT in localization of parathyroid adenoma or hyperplasia in patients with previous neck surgery
    Papathanassiou, Dimitri
    Flament, Jean-Bernard
    Pochart, Jean-Marie
    Patey, Martine
    Marty, Helene
    Liehn, Jean-Claude
    Schvartz, Claire
    CLINICAL NUCLEAR MEDICINE, 2008, 33 (06) : 394 - 397
  • [10] Parathyroid adenoma mimicking a cervical isthmic thyroid nodule: Value of SPECT/CT in the localization of ectopic parathyroid. A case report
    El Alaoui, M. Chafai
    Aschawa, H.
    Bellaoui, W.
    Aaouini, R.
    Bssis, A.
    Ben Rais, N.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2015, 39 : E91 - E94