Prospective ECG-gated High-Pitch Photon-Counting CT Angiography: Evaluation of measurement accuracy for aortic annulus sizing in TAVR planning

被引:1
作者
Yang, Y. [1 ]
Richter, R. [1 ]
Halfmann, M. C. [1 ]
Graafen, D. [1 ]
Hell, M. [2 ]
Vecsey-Nagy, M. [3 ,4 ]
Laux, G. [2 ]
Kavermann, L. [2 ]
Jorg, T. [1 ]
Geyer, M. [2 ]
Varga-Szemes, A. [3 ]
Emrich, T. [1 ,3 ]
机构
[1] Univ Med Ctr Mainz, Dept Diagnost & Intervent Radiol, Langenbeckstr 1, D-55131 Mainz, Germany
[2] Univ Med Ctr Mainz, Dept Cardiol, Langenbeckstr 1, D-55131 Mainz, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, 25 Courtenay Dr, Charleston, SC 29425 USA
[4] Semmelweis Univ, Heart & Vasc Ctr, 68 Varosmajor St, H-1122 Budapest, Hungary
关键词
TAVR; Aortic annulus measurement; prospective ECG-gated high-pitch CTA; Photon Counting CT; INTERMEDIATE RISK PATIENTS; VALVE-REPLACEMENT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; TRANSCATHETER; IMPLANTATION; STENOSIS; ARTIFACTS;
D O I
10.1016/j.ejrad.2024.111604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In planning transcatheter aortic valve replacement (TAVR), retrospective cardiac spiral-CT is recommended to measure aortic annulus with subsequent CT-angiography (CTA) to evaluate access routes. Photon- counting detector (PCD)-CT enables to assess the aortic annulus in desired cardiac phases, using prospective ECG-gated high-pitch CTA. The aim of this study was to evaluate the measurement accuracy of aortic annulus using prospective ECG-gated high-pitch CTA against retrospective spiral-CT reference. Method: Thirty patients underwent cardiac spiral-CT and prospective ECG-gated (30% R-R on aortic valve level) high-pitch CTA. Using propensity score matching, another 30 patients were identified whose CTA was performed using high-pitch mode without ECG-synchronization. Two investigators measured annular diameter, perimeter, and area on cardiac spiral-CT and high-pitch CTA. Results: The aortic valve was imaged in systole in 90 % of prospective ECG-gated CTA cases but only 50 % of non- ECG-gated CTA cases (p = 0.002). There was a strong correlation (r >= 0.94) without significant differences (p >= 0.09) between cardiac spiral-CT and prospective ECG-gated high-pitch CTA for all annulus measurements. In contrast, significant differences were found in annular short-axis diameter and area between cardiac spiral-CT and non-ECG-gated high-pitch CTA (p <= 0.03). Furthermore, prospective ECG-gated high-pitch CTA showed significantly reduced radiation exposure compared with cardiac spiral-CT (CTDI 4.52 vs. 24.10 mGy; p < 0.001). Conclusion: PCD-CT-based prospective ECG-gated high-pitch scans with targeted systolic acquisition at the level of the aortic valve can simultaneously visualize TAVR access routes and accurately measure systolic annulus size. This approach could aid in optimizing protocols to achieve lower radiation doses in the growing population of younger, low-risk TAVR patients.
引用
收藏
页数:8
相关论文
共 38 条
  • [1] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [2] Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
    Adams, David H.
    Popma, Jeffrey J.
    Reardon, Michael J.
    Yakubov, Steven J.
    Coselli, Joseph S.
    Deeb, G. Michael
    Gleason, Thomas G.
    Buchbinder, Maurice
    Hermiller, James, Jr.
    Kleiman, Neal S.
    Chetcuti, Stan
    Heiser, John
    Merhi, William
    Zorn, George
    Tadros, Peter
    Robinson, Newell
    Petrossian, George
    Hughes, G. Chad
    Harrison, J. Kevin
    Conte, John
    Maini, Brijeshwar
    Mumtaz, Mubashir
    Chenoweth, Sharla
    Oh, Jae K.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) : 1790 - 1798
  • [3] User's guide to correlation coefficients
    Akoglu, Haldun
    [J]. TURKISH JOURNAL OF EMERGENCY MEDICINE, 2018, 18 (03): : 91 - 93
  • [4] Transcatheter versus surgical aortic valve replacement in intermediate risk patients: a meta-analysis
    Arora, Sameer
    Misenheimer, Jacob A.
    Jones, Wesley
    Bahekar, Amol
    Caughey, Melissa
    Ramm, Cassandra J.
    Caranasos, Thomas G.
    Yeung, Michael
    Vavalle, John P.
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2016, 6 (03) : 241 - 249
  • [5] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Beeres, Martin
    Schell, Boris
    Mastragelopoulos, Aristidis
    Herrmann, Eva
    Kerl, Josef Matthias
    Gruber-Rouh, Tatjana
    Lee, Clara
    Siebenhandl, Petra
    Bodelle, Boris
    Zangos, Stephan
    Vogl, Thomas J.
    Jacobi, Volkmar
    Bauer, Ralf W.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (01) : 129 - 137
  • [6] Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole
    Bertaso, Angela G.
    Wong, Dennis T. L.
    Liew, Gary Y. H.
    Cunnington, Michael S.
    Richardson, James D.
    Thomson, Viji S.
    Lorraine, Brett
    Kourlis, George
    Leech, Diana
    Worthley, Matthew I.
    Worthley, Stephen G.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08) : 2091 - 2098
  • [7] Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography
    Blanke, Philipp
    Weir-McCall, Jonathan R.
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Jilaihawi, Hasan
    Marwan, Mohamed
    Norgaard, Bjarne L.
    Piazza, Niccolo
    Schoenhagen, Paul
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) : 1 - 20
  • [8] Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose
    Bodelle, Boris
    Fischbach, Constanze
    Booz, Christian
    Yel, Ibrahim
    Frellesen, Claudia
    Beeres, Martin
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 89 : 208 - 214
  • [9] Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: Comparison of systolic high-pitch vs. multiphasic data acquisition
    Capilli, Fabio
    Benndorf, Matthias
    Soschynski, Martin
    Hagar, Muhammad Taha
    Kharabish, Ahmed
    Neumann, Franz-Josef
    Pache, Gregor
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [10] Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description
    Cribier, A
    Eltchaninoff, H
    Bash, A
    Borenstein, N
    Tron, C
    Bauer, F
    Derumeaux, G
    Anselme, F
    Laborde, F
    Leon, MB