Anti-OTC antibody-conjugated fluorescent magnetic/silica and fluorescent hybrid silica nanoparticles for oxytetracycline detection

被引:0
|
作者
Kaliyaperumal, Viswanathan [1 ]
Al-Otibi, Fatimah Oleyan [2 ]
John, Ruth Sophila [3 ]
Alharbi, Raedah Ibrahim [2 ]
Gopal, Dhinakar Raj [3 ,4 ]
机构
[1] Saveetha Inst Med & Tech Sci SIMATS, Dept Chem, SIMATS Engn, Chennai 600077, India
[2] King Saud Univ, Coll Sci, Dept Bot & Microbiol, POB 22452, Riyadh 11495, Saudi Arabia
[3] Tamil Nadu Vet & Anim Sci Univ TANUVAS, Madras Vet Coll, Dept Biotechnol, Chennai 600051, India
[4] Tamil Nadu Vet & Anim Sci Univ TANUVAS, Ctr Anim Hlth Studies CAHS, Translat Res Platform Vet Biol, Chennai 600051, India
来源
OPEN CHEMISTRY | 2024年 / 22卷 / 01期
关键词
OTC detection; magnetic separator; fluorescent hybrid silica nanoparticles; fluorescent magnetic silica nanoparticles; sandwich assay; ANTIBIOTIC-RESIDUES; FOOD SAFETY; TETRACYCLINES; MILK;
D O I
10.1515/chem-2024-0066
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study presents two alternative fluorescent nanoparticle-based oxytetracycline (OTC) detection methods in milk samples. Rhodamine 6G-coated fluorescent hybrid silica nanoparticles and fluorescent magnetic/silica nanoparticles functionalized with anti-OTC antibodies were used in this test. The sandwich test format was utilized to compare anti-OTC antibody-conjugated fluorescent magnetic/silica nanoparticles with OTC/OTC antibody-conjugated fluorescent hybrid silica nanoparticles in an Eppendorf tube with magnetic separators. The magnetic separator helps to quickly retain all of the OTC captured by fluorescent magnetic core-shell nanoparticles in the milk sample. As a result, the assay time was dramatically shortened. The obtained linear range was 1.34 x 10-6 to 2.10 x 10-8 (M) (R 2 = 0.9954), the detection limit was 4.76 ng/mL, and the total assay time was 90 min. This approach was used to determine the OTC concentration in milk samples, and the maximum percentage (%) of interference was less than 3.0%, with a recovery rate of greater than 97.0%. This approach offers a high potential for residue detection in milk samples. With a total analysis period of less than 90 min, this approach provided the best way to determine the capture and detector nanoparticles' response.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Lectin-conjugated fluorescent silica nanoparticles for quantitative histopathology evaluations of tissue biopsies
    Wang, Yaqi
    Zimmt, Matthew
    Gnepp, Douglas
    Gildersleeve, Jeffrey
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [42] Antibody-Conjugated Rubpy Dye-Doped Silica Nanoparticles as Signal Amplification for Microscopic Detection of Vibrio cholerae O1
    Thepwiwatjit, Nualrahong
    Thattiyaphong, Aree
    Limsuwan, Pichet
    Tuitemwong, Kooranee
    Tuitemwong, Pravate
    JOURNAL OF NANOMATERIALS, 2013, 2013
  • [43] Core/shell fluorescent magnetic silica-coated composite nanoparticles for bioconjugation
    He, Rong
    You, Xiaogang
    Shao, Jun
    Gao, Feng
    Pan, Bifeng
    Cui, Daxiang
    NANOTECHNOLOGY, 2007, 18 (31)
  • [44] Fluorescent detection of ATP based on signaling DNA aptamer attached silica nanoparticles
    Wang, Yanyan
    Wang, Yusong
    Liu, Bin
    NANOTECHNOLOGY, 2008, 19 (41)
  • [45] Bioprobes Based on Aptamer and Silica Fluorescent Nanoparticles for Bacteria Salmonella typhimurium Detection
    Wang, Qiu-Yue
    Kang, Yan-Jun
    NANOSCALE RESEARCH LETTERS, 2016, 11
  • [46] Fluorescent silica nanoparticles and glass surfaces for the detection and removal of Pd(II) ions
    Junhui Ran
    Haiying Wang
    Xinjian Cheng
    Journal of Materials Science, 2016, 51 : 8502 - 8515
  • [47] Tetraphenylethene probe based fluorescent silica nanoparticles for the selective detection of nitroaromatic explosives
    Nawaz, Muhammad Azhar Hayat
    Meng, Lianjie
    Zhou, Huipeng
    Ren, Jia
    Shahzad, Sohail Anjum
    Hayat, Akhtar
    Yu, Cong
    ANALYTICAL METHODS, 2021, 13 (06) : 825 - 831
  • [48] Tetraphenylethene probe based fluorescent silica nanoparticles for the selective detection of nitroaromatic explosives
    State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun
    130022, China
    不详
    230026, China
    不详
    54000, Pakistan
    不详
    22060, Pakistan
    Anal. Methods, 1759, 6 (825-831):
  • [49] Bioprobes Based on Aptamer and Silica Fluorescent Nanoparticles for Bacteria Salmonella typhimurium Detection
    Qiu-Yue Wang
    Yan-Jun Kang
    Nanoscale Research Letters, 2016, 11
  • [50] A novel fluorescent aptasensor for selective and sensitive detection of digoxin based on silica nanoparticles
    Emrani, Ahmad Sarreshtehdar
    Taghdisi, Seyed Mohammad
    Danesh, Noor Mohammad
    Jalalian, Seyed Hamid
    Ramezani, Mohammad
    Abnous, Khalil
    ANALYTICAL METHODS, 2015, 7 (09) : 3814 - 3818