Cardiac arrhythmia beat classification using DOST and PSO tuned SVM

被引:65
|
作者
Raj, Sandeep [1 ]
Ray, Kailash Chandra [1 ]
Shankar, Om [2 ]
机构
[1] Indian Inst Technol Patna, Dept Elect Engn, Patna 801103, Bihar, India
[2] Banaras Hindu Univ, Inst Med Sci, Dept Cardiol, Varanasi 221005, Uttar Pradesh, India
关键词
Cardiac arrhythmia beat; DOST; PCA; SVM; PSO; RECOGNITION; TRANSFORM; FEATURES;
D O I
10.1016/j.cmpb.2016.08.016
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: The increase in the number of deaths due to cardiovascular diseases (CVDs) has gained significant attention from the study of electrocardiogram (ECG) signals. These ECG signals are studied by the experienced cardiologist for accurate and proper diagnosis, but it becomes difficult and time-consuming for long-term recordings. Various signal processing techniques are studied to analyze the ECG signal, but they bear limitations due to the non-stationary behavior of ECG signals. Hence, this study aims to improve the classification accuracy rate and provide an automated diagnostic solution for the detection of cardiac arrhythmias. Methods: The proposed methodology consists of four stages, i.e. filtering, R-peak detection, feature extraction and classification stages. In this study, Wavelet based approach is used to filter the raw ECG signal, whereas Pan Tompkins algorithm is used for detecting the R-peak inside the ECG signal. In the feature extraction stage, discrete orthogonal Stockwell transform (DOST) approach is presented for an efficient time-frequency representation (i.e. morphological descriptors) of a time domain signal and retains the absolute phase information to distinguish the various non-stationary behavior ECG signals. Moreover, these morphological descriptors are further reduced in lower dimensional space by using principal component analysis and combined with the dynamic features (i.e based on RR interval of the ECG signals) of the input signal. This combination of two different kinds of descriptors represents each feature set of an input signal that is utilized for classification into subsequent categories by employing PSO tuned support vector machines (SVM). Results: The proposed methodology is validated on the baseline MIT-BIH arrhythmia database and evaluated under two assessment schemes, yielding an improved overall accuracy of 99.18% for sixteen classes in the category-based and 89.10% for five classes (mapped according to AAMI standard) in the patient-based assessment scheme respectively to the state of-art diagnosis. The results reported are further compared to the existing methodologies in literature. Conclusions: The proposed feature representation of cardiac signals based on symmetrical features along with PSO based optimization technique for the SVM classifier reported an improved classification accuracy in both the assessment schemes evaluated on the benchmark MIT-BIH arrhythmia database and hence can be utilized for automated computer aided diagnosis of cardiac arrhythmia beats. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 177
页数:15
相关论文
共 50 条
  • [1] Performance Analysis for Arrhythmia Classification using PSO, GWO and SVM
    Mita, Haris J.
    Babu, Ganesh C.
    Gowri, Shankar M.
    ICSPC'21: 2021 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATION (ICPSC), 2021, : 67 - 72
  • [2] Cardiac Arrhythmia Classification of ECG Signal using Morphology and Heart Beat Rate
    Senapati, Manoj Kumar
    Senapati, Mrutyunjaya
    Maka, Srinivasu
    2014 FOURTH INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING AND COMMUNICATIONS (ICACC), 2014, : 60 - 63
  • [3] ECG Signal Analysis Using DCT-Based DOST and PSO Optimized SVM
    Raj, Sandeep
    Ray, Kailash Chandra
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (03) : 470 - 478
  • [4] Multiclass Classification of Cardiac Arrhythmia Using Improved Feature Selection and SVM Invariants
    Mustaqeem, Anam
    Anwar, Syed Muhammad
    Majid, Muahammad
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2018, 2018
  • [5] Real-Time Classification for Cardiac Arrhythmia ECG Beat
    Ihsanto, Eko
    Ramli, Kalamullah
    Sudiana, Dodi
    2019 16TH INTERNATIONAL CONFERENCE ON QUALITY IN RESEARCH (QIR) / INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND COMPUTER ENGINEERING, 2019, : 64 - 68
  • [6] ECG Beat Classification Using Wavelets and SVM
    Faziludeen, Shameer
    Sabiq, P., V
    2013 IEEE CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES (ICT 2013), 2013, : 815 - 818
  • [7] QRS Complex Detection and Arrhythmia Classification using SVM
    Barhatte, Alka S.
    Ghongade, Rajesh
    Thakare, Abhishek S.
    2015 COMMUNICATION, CONTROL AND INTELLIGENT SYSTEMS (CCIS), 2015, : 239 - 243
  • [8] A Survey of ECG Classification for Arrhythmia Diagnoses Using SVM
    Ayushi, Doshi
    Nikita, Bhatt
    Nitin, Shah
    INTELLIGENT COMMUNICATION TECHNOLOGIES AND VIRTUAL MOBILE NETWORKS, ICICV 2019, 2020, 33 : 574 - 590
  • [9] Spam Host Classification using PSO-SVM
    Enache, Adriana-Cristina
    Sgarciu, Valentin
    2014 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, 2014,
  • [10] Cardiac Arrhythmia Classification Using Electrocardiogram
    Faust, Oliver
    Martis, Roshan Joy
    Min, Lee
    Zhong, Garrick Lou Zhi
    Yu, Wenwei
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (03) : 448 - 454