ASSESSMENT OF INVASIVE FRACTIONAL FLOW RESERVE PROCEDURES USING COMPUTATIONAL FLUID DYNAMICS

被引:0
作者
Abuouf, Yasser [1 ]
Albadawi, Muhamed [1 ]
Ookawara, Shinichi [1 ]
Ahmed, Mahmoud [1 ]
机构
[1] Egypt Japan Univ Sci & Technol E JUST, Dept Energy Resources Engn, Alexandria, Egypt
来源
PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5 | 2020年
关键词
Stenosis; Fractional flow reserve (FFR); CFD; BLOOD-FLOW;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Coronary artery disease is the abnormal contraction of heart supply blood vessel. It may lead to major consequences such as heart attack and death. This narrowing in the coronary artery limits the oxygenated blood flow to the heart. Thus, diagnosing its severity helps physicians to select the appropriate treatment plan. Fractional Flow Reserve (FFR) is one of the most accurate methods to pinpoint the stenosis severity. The advantages of FFR are high accuracy, immediate estimation of the severity of the stenosis, and concomitant treatment using balloon or stent. Nevertheless, the main disadvantage of the FFR is being an invasive procedure that requires an incision under anesthesia. Moreover, inserting the guidewire across the stenosis may result in a 'tight-fit' between the vessel lumen and the guidewire. This may cause an increase in the measured pressure drop, leading to a false estimation of the blood flow parameters. To estimate the errors in diagnosis procedures, a comprehensive three-dimensional model blood flow along with guidewire is developed. Reconstructed three-dimensional coronary artery geometry from a patient-specific scan is used. Blood is considered non-Newtonian and the flow is pulsatile. The comprehensive model is numerically simulated using boundary conditions. Based on the predicted results, the ratio between pressure drop and distal dynamic pressure (CDP) is studied. The predicted results for each case are compared with the control case (the case without guidewire) and analyzed. It was found that simulating the model by placing the guidewire at a full position prior to the simulation leads to an overestimation of the CDP as it increases by 34.3%. However, simulating the procedure of guidewire insertion is more accurate. It shows that the CDP value increases by 7%.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] Abuouf Y., 2019, ASME INT MECH ENG C
  • [2] Analysis of the effect of guidewire position on stenosis diagnosis using computational fluid dynamics
    Abuouf, Yasser
    Ookawara, Shinichi
    Ahmed, Mahmoud
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 121
  • [3] Ahmed M., 2019, ASME INT MECH ENG C, DOI [10.1115/IMECE2019-10425.V003T04A002., DOI 10.1115/IMECE2019-10425]
  • [4] Permeability and fluid flow-induced wall shear stress of bone tissue scaffolds: Computational fluid dynamic analysis using Newtonian and non-Newtonian blood flow models
    Ali, Davar
    Sen, Sadri
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 99 : 201 - 208
  • [5] Hemodynamic diagnostics of epicardial coronary stenoses:: in-vitro experimental and computational study
    Banerjee, Rupak K.
    Ashtekar, Koustubh D.
    Helmy, Tarek A.
    Effat, Mohamed A.
    Back, Lloyd H.
    Khoury, Saeb F.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)
  • [6] Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound
    Leber, AW
    Knez, A
    von Ziegler, F
    Becker, A
    Nikolaou, K
    Paul, S
    Wintersperger, B
    Reiser, M
    Becker, CR
    Steinbeck, G
    Boekstegers, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) : 147 - 154
  • [7] Pijls N.H., 2000, Coronary Pressure
  • [8] Saraiva I. S., 2019, Geometry Reconstruction of a Patient-Specific Right Coronary Artery with Atherosclerotic Plaque for CFD Study BT-VipIMAGE 2019, P531
  • [9] Sommer K. N., 2019, Proc. SPIE
  • [10] Tu J, 2015, BIOL MED PHYS BIOMED, P1, DOI 10.1007/978-94-017-9594-4