A multivariable control strategy based on fuzzy logic interference rule for a solar-driven, direct air-cooled H2O-LiBr absorption chiller

被引:0
作者
Castro, J. [1 ]
Farnos, J. [1 ]
Papakokkinos, G. [1 ,3 ]
Zheng, J. [1 ,2 ]
Torras, S. [1 ]
机构
[1] Univ Politecn Catalunya BarcelonaTech UPC, Ctr Tecnol Transferencia Calor CTTC, ESEIAAT, Colom 11, E-08222 Terrassa, Barcelona, Spain
[2] GD Midea Heating & Ventilating Equipment Co Ltd, Foshan 528311, Guangdong, Peoples R China
[3] Cyprus Inst, Energy Environm & Water Res Ctr, Konstantinou Kavafi St 20, CY-2121 Nicosia, Cyprus
基金
欧盟地平线“2020”;
关键词
Absorption; H2O-LiBr; Solar thermal; Control; Crystallization; HOT-WATER DRIVEN; SMALL-CAPACITY; FRICTION CORRELATIONS; DYNAMIC SIMULATION; FEEDBACK-CONTROL; HEAT-EXCHANGERS; COOLING SYSTEM; MASS-TRANSFER; MODEL; TECHNOLOGIES;
D O I
10.1016/j.solener.2024.112579
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The operation of a solar-driven H2O-LiBr Absorption Chiller (AbC) is subjected to various limitations regarding its ability to satisfy efficiently the required cooling demand while avoiding certain internal conditions, such as H2O-LiBr solution crystallization and water freezing. These circumstances would lead to problematic situations and jeopardize the continuous operation of the system. Thus, the development of accurate control strategies is an issue of interest. A new operational control strategy approach is introduced and tested through simulation studies, by employing a transient model of the entire solar cooling application. A prototype under development is used for the parametrization of the direct air-cooled AbC model used in the simulations. The developed control strategy aims to minimize the electrical consumption of the auxiliary components of the AbC (i.e., fan, pumps) during the partial load operation period, by using a fuzzy logic interference rule for determining the cooling capacity demand and then applying an optimization algorithm for determining the velocity of the auxiliary components. Within the proposed control strategy, a fast-calculation model is embedded, which predicts the chiller's capacity under variable external conditions and partial load operation. The electrical COP is increased up to 2.2 times with respect to a baseline case, based on a basic two-step control strategy, while allowing the chiller to operate smoother, minimizing the crystallization and freezing risk.
引用
收藏
页数:18
相关论文
共 54 条
[21]   EXPERIMENTAL INVESTIGATION INTO EFFECT OF SURFACE THERMAL-CONDUCTIVITY ON RATE OF HEAT-TRANSFER IN DROPWISE CONDENSATION [J].
HANNEMANN, RJ ;
MIKIC, BB .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1976, 19 (11) :1309-1317
[22]  
Jani S., 2012, International Science and Engineering Investigations, V1, P79
[23]  
johnsanidopoulos, About us
[24]   Thermodynamic properties of lithium bromide-water solutions at high temperatures [J].
Kaita, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (05) :374-390
[25]   Heat transfer and friction correlations for wavy plate fin-and-tube heat exchangers [J].
Kim, NH ;
Yun, JH ;
Webb, RL .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1997, 119 (03) :560-567
[26]   Air-side float transfer and friction correlations for plain fin-and-tube heat exchangers with staggered tube arrangements [J].
Kim, NH ;
Youn, B ;
Webb, RL .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1999, 121 (03) :662-667
[27]  
Koeppel E.A., 1995, HVACR RES, V1, P325, DOI DOI 10.1080/10789669.1995.10391328
[28]  
Kohlenbach P., Ph.D. thesis
[29]  
Kuhn A., 2008, P 1 INT C SOL HEAT C, P1
[30]  
Labus J., 2011, Modelling of Small Capacity Absorption Chillers Driven by Solar Thermal Energy or Waste Heat