Design optimization of the cooling systems with PCM-to-air heat exchanger for the energy saving of the residential buildings

被引:5
作者
Zhang, Qian [1 ]
Sazon, Thor Alexis Salazar [1 ]
Fadnes, Fredrik Skaug [1 ,2 ]
Peng, Xianyong [3 ]
Ahmed, Naveed [1 ,4 ]
Nikpey, Homam [1 ]
Mansouri, Mohammad [1 ]
Assadi, Mohsen [1 ]
机构
[1] Univ Stavanger, Dept Energy & Petr Engn, Stavanger, Norway
[2] Norconsult AS, Oslo, Norway
[3] China Univ Min & Technol, Sch Low Carbon Energy & Power Engn, Xuzhou, Peoples R China
[4] Natl Univ Sci & Technol NUST, US Pakistan Ctr Adv Studies Energy USPCASE, H-12 Sect, Islamabad, Pakistan
关键词
Space cooling; Phase change material; Design optimization; Artificial neural network; PHASE-CHANGE MATERIALS; ECONOMIC-ANALYSIS; STORAGE TANK; PERFORMANCE ANALYSIS; THERMAL PERFORMANCE; NEURAL-NETWORKS; PUMP SYSTEM; SIMULATION; PARAMETERS; MODEL;
D O I
10.1016/j.ecmx.2024.100630
中图分类号
O414.1 [热力学];
学科分类号
摘要
Driven by a rapid surge in cooling demand in buildings, the energy consumption dedicated to cooling has experienced remarkable growth. To address this challenge, the adoption of latent heat thermal energy storage utilizing phase change materials (PCM) has gained significant momentum in recent years. This paper presents the design and evaluation of an integrated latent heat thermal energy storage (ILHTES) system tailored for residential buildings. This system integrates a PCM-to-air heat exchanger (PAHX) with an air conditioning unit. Modelica language is utilized to develop a numerical model for the ILHTES system. The heat transfer model of the PAHX is developed and validated using existing literature data. To simulate the dynamic behavior and energy consumption of the residential building, the open -source library AixLib is adopted. The developed ILHTES system model is used for the optimization of key design variables, including the PCM slab thickness and air flow rate, based on the results of long-term simulations covering the entire cooling season. Evaluation of the energy saving potential of the optimized ILHTES systems is carried out in comparison to conventional air conditioning systems, considering various climatic conditions in five European cities. The results highlight the profound impact of PCM types on the Energy Saving Ratio (ESR) throughout the entire cooling season. Among the four commercially available PCMs examined - RT27, RT25, RT20, and RT18 - RT25 consistently outperforms the others. Across all five cities investigated, using RT25 leads to a minimum ESR of 16% in Catania and a maximum ESR of 44.7% in Stockholm for the entire cooling season.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Locating room air-conditioners at floor level for energy saving in residential buildings
    Gao, C. F.
    Lee, W. L.
    Hua, Chen
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (08) : 2009 - 2019
  • [42] Solar seasonal thermal energy storage for space heating in residential buildings: Optimization and comparison with an air-source heat pump
    Lu, Jie
    He, Guoqing
    Mao, Feng
    ENERGY SOURCES PART B-ECONOMICS PLANNING AND POLICY, 2020, 15 (05) : 279 - 296
  • [43] Energy saving evaluation of passive systems for residential buildings in hot and dry regions
    Goudarzi, Hossein
    Mostafaeipour, Ali
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 68 : 432 - 446
  • [44] Enhancing cooling performance and economic analysis of a vertical earth air heat exchanger (VEAHE) through geometric shape optimization
    Rostami, Mohammadreza Hasandust
    HEAT TRANSFER, 2024, 53 (06) : 2661 - 2688
  • [45] Managing heat rejected from air conditioning systems to save energy and improve the microclimates of residential buildings
    Hsieh, Chun-Ming
    Aramaki, Toshiya
    Hanaki, Keisuke
    COMPUTERS ENVIRONMENT AND URBAN SYSTEMS, 2011, 35 (05) : 358 - 367
  • [46] Influence of operational and design parameters on the performance of a PCM based heat exchanger for thermal energy storage - A review
    Kalapala, Lokesh
    Devanuri, Jaya Krishna
    JOURNAL OF ENERGY STORAGE, 2018, 20 : 497 - 519
  • [47] Advances in standalone and hybrid earth-air heat exchanger (EAHE) systems for buildings: A review
    Soares, N.
    Rosa, N.
    Monteiro, H.
    Costa, J. J.
    ENERGY AND BUILDINGS, 2021, 253
  • [48] Experimental investigation of dedicated desiccant wheel outdoor air cooling systems for nearly zero energy buildings
    Chen, Liu
    Chu, Yujie
    Deng, Wenjie
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 134 : 265 - 277
  • [49] Thermo-economic optimization of a multi-source (air/sun/ground) residential heat pump with a water/PCM thermal storage
    Pelella, Francesco
    Zsembinszki, Gabriel
    Viscito, Luca
    Mauro, Alfonso William
    Cabeza, Luisa F.
    APPLIED ENERGY, 2023, 331
  • [50] Passive cooling systems in livestock buildings towards energy saving: A critical review
    Firfiris, V. K.
    Martzopoulou, A. G.
    Kotsopoulos, T. A.
    ENERGY AND BUILDINGS, 2019, 202