A hybrid repair strategy for full-thickness cartilage defects: Long-term experimental study in eight horses

被引:0
作者
Fugazzola, Maria C. [1 ]
De Ruijter, Mylene [1 ,2 ]
Veraa, Stefanie [1 ]
Plomp, Saskia [1 ,2 ]
van Buul, Ward [3 ]
Hermsen, Gied [3 ]
van Weeren, Rene [1 ]
机构
[1] Univ Utrecht, Fac Vet Med, Dept Clin Sci, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Orthoped, Utrecht, Netherlands
[3] Joinstphere Co, Eindhoven, Netherlands
关键词
biomechanics; cartilage; fibrocartilage; osteoarthritis; ARTICULAR-CARTILAGE; SUBCHONDRAL BONE; CHONDRAL DEFECTS; MICROFRACTURE; IMPLANT; TISSUE; EQUINE; OSTEOARTHRITIS; HYDROGELS; MODELS;
D O I
10.1002/jor.25972
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of this study was to evaluate a non-resorbable implant for the focal repair of chondral defects in eight adult horses with 12-month follow-up. The bi-layered construct composed of a polycarbonate-urethane-urea biomaterial which was printed in 3D fashion onto a bone anchor was implanted into surgically created osteochondral defects into the femoropatellar joints of eight horses. The analysis of post-mortem outcomes were compared to defects treated with microfracture in the same animal on the contralateral femoropatellar jointfemoropatellar joint. The overall macroscopic scoring after 12 months yielded higher scores in the OCI-treated stifles compared to MF treatment (p = 0.09) with better quality and filling of the defect. Histology revealed good anchorage of repair tissue growing into the 3D structure of the implant and histopathology scoring for adjacent native cartilage showed no difference between groups. MRI and micro-CT showed overall less sclerotic reactions in the surrounding bone in the implant group and no foreign body reaction was detected. Biomechanical analysis of the repair tissue revealed a significantly higher peak modulus (p < 0.05) in the implant group (0.74 +/- 0.45) compared to the microfracture control group (0.15 +/- 0.11). Dynamic loading yielded higher values for the repair tissue overgrowing the implant group (0.23 +/- 0.17) compared to the microfracture control (0.06 +/- 0.06) (p < 0.05). The bi-layered osteochondral implant provided a safe implant for focal repair of full-thickness osteochondral defects, as no adverse reaction was seen within the joints and the level of degeneration of adjacent cartilage to the repair site was not different compared to that seen in defects treated with microfracture after 12 months.
引用
收藏
页码:59 / 69
页数:11
相关论文
共 38 条
  • [1] A systematic review of the relationship between subchondral bone features, pain and structural pathology in peripheral joint osteoarthritis
    Barr, Andrew J.
    Campbell, T. Mark
    Hopkinson, Devan
    Kingsbury, Sarah R.
    Bowes, Mike A.
    Conaghan, Philip G.
    [J]. ARTHRITIS RESEARCH & THERAPY, 2015, 17
  • [2] Becher C., 2011, MINIMUM 5YEAR RESULT, V131, P1135, DOI [10.1007/s00402-011-1323-4, DOI 10.1007/S00402-011-1323-4]
  • [3] ADAMTS5-/- mice have less subchondral bone changes after induction of osteoarthritis through surgical instability: implications for a link between cartilage and subchondral bone changes
    Botter, S. M.
    Glasson, S. S.
    Hopkins, B.
    Clockaerts, S.
    Weinans, H.
    van Leeuwen, J. P. T. M.
    van Osch, G. J. V. M.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (05) : 636 - 645
  • [4] Buckland-Wright Christopher, 2004, Osteoarthritis Cartilage, V12 Suppl A, pS10
  • [5] Temporal trends in the disease burden of osteoarthritis from 1990 to 2019, and projections until 2030
    Chen, Xiaoqing
    Tang, Haifeng
    Lin, Jinding
    Zeng, Rongdong
    [J]. PLOS ONE, 2023, 18 (07):
  • [6] Chu CR, 2010, TISSUE ENG PART B-RE, V16, P105, DOI [10.1089/ten.teb.2009.0452, 10.1089/ten.TEB.2009.0452]
  • [7] The performance of resurfacing implants for focal cartilage defects depends on the degenerative condition of the opposing cartilage
    Damen, A. H. A.
    Nickien, M.
    Ito, K.
    van Donkelaar, C. C.
    [J]. CLINICAL BIOMECHANICS, 2020, 79
  • [8] Use of Synthetic Osteochondral Implants to Treat Bilateral Shoulder Osteochondritis Dissecans in a Dog
    Danielski, Alan
    Farrell, Michael
    [J]. VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2018, 31 (05) : 385 - 389
  • [9] A decreased subchondral trabecular bone tissue elastic modulus is associated with pre-arthritic cartilage damage
    Day, JS
    Ding, M
    van der Linden, JC
    Hvid, I
    Sumner, DR
    Weinans, H
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (05) : 914 - 918
  • [10] Diloksumpan A., 2021, J TRIAL ERROR, V2, P7, DOI [10.36850/E3, DOI 10.36850/E3]