NH3 line broadening coefficients and intensities measurement and impurities determination in emerging applications: CCUS, Biomethane and H2

被引:1
作者
Zhu, Denghao [1 ]
Seifert, Leopold [1 ]
Agarwal, Sumit [1 ]
Shu, Bo [1 ]
Fernandes, Ravi [1 ,2 ]
Qu, Zhechao [1 ]
机构
[1] Phys Tech Bundesanstalt, Dept Phys Chem, Braunschweig, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Internal Combust Engines, Braunschweig, Germany
关键词
Ammonia; TDLAS; Optical gas standard; Broadening coefficient; Line intensity; Gas impurity; LASER; SPECTROSCOPY; AMMONIA; SENSOR; N2O; SPECTROMETER; CO2;
D O I
10.1016/j.saa.2024.124642
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A mid -infrared quantum cascade laser (Mid-IR QCL) coupled with a Single Pass Cell and a Multi Pass Cell, was utilized to measure ammonia (NH 3 ) absorption spectroscopic parameters and determine NH 3 impurities toward three emerging applications. We for the first time measured the pressure broadening coefficients perturbed by Air, O 2 , N 2 , He, CO 2 , CH 4 , and H 2 and the line intensities of six NH 3 transition lines near 1084.6 cm - 1 . The measured NH 3 -He, NH 3 -Air, and NH 3 -CO 2 broadening coefficients align with HITRAN database, while NH 3 -H 2 coefficients exhibit a maximum discrepancy of 46 %. Deviations between the measured line intensities and HITRAN database are minimal. Nevertheless, the uncertainties of line intensities have been significantly reduced from 20 % in HITRAN to below 3 %. The newly measured line parameters are utilized to address NH 3 impurity requirements outlined in CCUS (ISO 27913:2016), Biomethane (EN 16723:2016), and H 2 (ISO 14687:2019) standards. Based on the concept of optical gas standard (OGS), the NH 3 impurity detection requirements in all three standards have been fulfilled with an uncertainty of 1.35 %. The precision of the NH 3 -OGS is 800 part per trillion (ppt) with an integration time of 100 s. The repeatability of the NH 3 -OGS is 130 ppt for a continuous measurement time of 48 min. Notably, the NH 3 -OGS effectively addresses the highly nonlinear adsorption-desorption dynamics, underscoring the potential of OGS as a calibration -free and SI-traceable metrological gas analysis instrument.
引用
收藏
页数:11
相关论文
共 49 条
[1]   Hydrogen as an energy vector [J].
Abdin, Zainul ;
Zafaranloo, Ali ;
Rafiee, Ahmad ;
Merida, Walter ;
Lipinski, Wojciech ;
Khalilpour, Kaveh R. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 120
[2]   Ammonia line strengths and N2-, O2-, Ar-, He-, and self-broadening coefficients in the v2 band near 10.4 μm [J].
Alturaifi, Sulaiman A. ;
Petersen, Eric L. .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2021, 262
[3]  
[Anonymous], 2016, ISO 27913.
[4]   Near-infrared tunable diode laser spectrometer for the remote sensing of vehicle emissions [J].
Barrass, S ;
Gérard, Y ;
Holdsworth, RJ ;
Martin, PA .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (14) :3353-3360
[5]   Recyclable metal fuels for clean and compact zero-carbon power [J].
Bergthorson, Jeffrey M. .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2018, 68 :169-196
[6]   Absolute validation of a diode laser hygrometer via intercomparison with the German national primary water vapor standard [J].
Buchholz, B. ;
Boese, N. ;
Ebert, V. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 116 (04) :883-899
[7]   Strategies to achieve a carbon neutral society: a review [J].
Chen, Lin ;
Msigwa, Goodluck ;
Yang, Mingyu ;
Osman, Ahmed I. ;
Fawzy, Samer ;
Rooney, David W. ;
Yap, Pow-Seng .
ENVIRONMENTAL CHEMISTRY LETTERS, 2022, 20 (04) :2277-2310
[8]   A critical review on deployment planning and risk analysis of carbon capture, utilization, and storage (CCUS) toward carbon neutrality [J].
Chen, Siyuan ;
Liu, Jiangfeng ;
Zhang, Qi ;
Teng, Fei ;
McLellan, Benjamin C. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 167
[9]   Re-analysis of ammonia spectra: Updating the HITRAN 14NH3 database [J].
Down, Michael J. ;
Hill, Christian ;
Yurchenko, Sergei N. ;
Tennyson, Jonathan ;
Brown, Linda R. ;
Kleiner, Isabelle .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 130 :260-272
[10]   Mid-infrared fiber-coupled laser absorption sensor for simultaneous NH3 and NO monitoring in flue gases [J].
Duan, Kun ;
Ji, Yongbin ;
Wen, Daxin ;
Lu, Zhimin ;
Xu, Ke ;
Ren, Wei .
SENSORS AND ACTUATORS B-CHEMICAL, 2023, 374