New Instrument for Time-Resolved OH and HO2 Quantification in High-Pressure Laboratory Kinetics Studies

被引:1
|
作者
Sheps, Leonid [1 ]
Au, Kendrew [1 ]
机构
[1] Sandia Natl Labs, Combust Res Facil, Livermore, CA 94551 USA
来源
JOURNAL OF PHYSICAL CHEMISTRY A | 2024年 / 128卷 / 19期
关键词
LOW-TEMPERATURE OXIDATION; GAS-PHASE REACTIONS; ATMOSPHERIC CHEMISTRY; FLUORESCENCE ASSAY; RADICALS; SPECTROSCOPY; CALIBRATION; EXPANSION; REACTOR;
D O I
10.1021/acs.jpca.4c00994
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We have constructed a new time-resolved high-pressure fluorescence assay by gas expansion (HP-FAGE) apparatus, optimized for the detection of OH and HO2 radicals in complex gas-phase reactions. The new instrument fills a gap in the existing experimental toolkit for chemical kinetics by enabling the quantification of two key reactive species with microsecond time resolution from high-pressure sources, which was previously not attainable. The HP-FAGE is interfaced with a flow reactor, designed for pressures up to 100 bar and temperatures up to 1000 K, in which reactions are initiated by laser photolysis of radical precursors at repetition rates of 1-10 Hz. The HP-FAGE samples gas out of the reactor into a miniature FAGE chamber, where OH is detected by resonant laser-induced fluorescence using a time-delayed probe laser pulse. HO2 is converted to OH via reaction with NO and then detected by OH fluorescence. The novel FAGE design places the probe region very close to the gas expansion, minimizing the transport time of sampled molecules and resulting in time resolution better than 20 mu s for both OH and HO2. We calibrate the sensitivity of HP-FAGE, validate its performance with measurements of well-known reaction kinetics (OH + CH4, OH + OH, OH + HO2, and HO2 + HO2), and discuss prospects for its future use.
引用
收藏
页码:3916 / 3925
页数:10
相关论文
共 50 条
  • [21] In situ multipurpose time-resolved spectrometer for monitoring nanoparticle generation in a high-pressure fluid
    Wei, Shaoyu
    Saitow, Ken-ichi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07):
  • [22] Time-resolved measurement of high-pressure phase transition of fluorite under shock loading
    Toshimori Sekine
    Takamichi Kobayashi
    Physics and Chemistry of Minerals, 2011, 38 : 305 - 310
  • [23] Kinetic study of reaction C2H5 + HO2 in a photolysis reactor with time-resolved Faraday rotation spectroscopy
    Zhong, Hongtao
    Yan, Chao
    Teng, Chu C.
    Ma, Guoming
    Wysocki, Gerard
    Ju, Yiguang
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2021, 38 (01) : 871 - 880
  • [24] HIGH-PRESSURE FALLOFF CURVES AND SPECIFIC RATE CONSTANTS FOR THE REACTIONS H + O2 REVERSIBLE HO2 REVERSIBLE HO + O
    COBOS, CJ
    HIPPLER, H
    TROE, J
    JOURNAL OF PHYSICAL CHEMISTRY, 1985, 89 (02): : 342 - 349
  • [25] TIME-RESOLVED NEAR-INFRARED EMISSION FROM A PULSED HIGH-PRESSURE CESIUM LAMP
    LEVY, S
    APPLIED OPTICS, 1972, 11 (12): : 2983 - &
  • [26] A TIME-RESOLVED RAMAN-STUDY OF INHOMOGENEOUS DEPHASING IN HIGH-PRESSURE MOLECULAR-CRYSTALS
    CROWELL, RA
    CHRONISTER, EL
    CHEMICAL PHYSICS LETTERS, 1992, 195 (5-6) : 602 - 608
  • [27] High-pressure instrument for small- and wide-angle x-ray scattering. II. Time-resolved experiments
    Steinhart, M
    Kriechbaum, M
    Pressl, K
    Amenitsch, H
    Laggner, P
    Bernstorff, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (02): : 1540 - 1545
  • [28] Cell design for picosecond time-resolved infrared spectroscopy in high-pressure liquids and supercritical fluids
    Sun, Xue-Zhong
    Portius, Peter
    Grills, David C.
    Cowan, Alexander J.
    George, Michael W.
    APPLIED SPECTROSCOPY, 2008, 62 (01) : 24 - 29
  • [29] High-Pressure Gas Measurement Using Time-Resolved Rotational CARS with Temporally Asymmetric Pulses
    Iwata, Katsuya
    Saito, Yoichi
    Ito, Terumasa
    Obara, Yuki
    Kameda, Masaharu
    Misawa, Kazuhiko
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2020,
  • [30] Simultaneous, time-resolved measurements of OH and HO2 radicals by coupling of high repetition rate LIF and cw-CRDS techniques to a laser photolysis reactor and its application to the photolysis of H2O2
    A. E. Parker
    C. Jain
    C. Schoemaecker
    P. Szriftgiser
    O. Votava
    C. Fittschen
    Applied Physics B, 2011, 103 : 725 - 733