A FLEXIBLE HAIR-LIKE LASER INDUCED GRAPHITIC SENSOR FOR LOW FLOW RATE SENSING APPLICATIONS

被引:0
作者
Abbasnejad, Behrokh [1 ]
McGloin, David [1 ]
Clemon, Lee [2 ]
机构
[1] Univ Technol Sydney, Sch Elect & Data Engn, Sydney, NSW, Australia
[2] Univ Technol Sydney, Sch Mech & Mechatron Engn, Sydney, NSW, Australia
来源
PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5 | 2020年
关键词
FAILURE MODE;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Direct low flow sensing is of interest to many applications in medical and biochemical industries. Low flow rate measurement is still challenging, and conventional flow sensors such as hot films, hot wires and Pitot probes are not capable of measuring very low flow rates accurately. In some applications that require flow measurement in a small diameter tubing (e.g. intravenous (IV) infusion), using such sensors also becomes mechanically impractical. Herein, a flexible laser-induced graphitic (LIG) piezoresistive flow sensor has been fabricated in a cost-effective single processing step. The capability of the LIG sensor in very low flow rate measurement has been investigated by embedding the sensor within an intravenous (IV) line. The embedded LIG hair-like sensor was tested at ambient temperature within the IV line at flow rates ranging from 0 m/s to 0.3 m/s (IV infusion free-flow rate). The LIG hair-like sensor presented in this study detects live flow rates of IV infusions with a threshold detection limit as low as 0.02 m/s. Moreover, the deformation of the LIG hair-like sensor that lead to resistance change in response to various flow rates is simulated using COMSOL Multiphysics.
引用
收藏
页数:5
相关论文
共 16 条
  • [1] Design of a safer approach to intravenous drug infusions: failure mode effects analysis
    Apkon, M
    Leonard, J
    Probst, L
    DeLizio, L
    Vitale, R
    [J]. QUALITY & SAFETY IN HEALTH CARE, 2004, 13 (04): : 265 - 271
  • [2] Microwave TDR for Real-Time Control of Intravenous Drip Infusions
    Cataldo, Andrea
    Cannazza, Giuseppe
    Giaquinto, Nicola
    Trotta, Amerigo
    Andria, Gregorio
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (07) : 1866 - 1873
  • [3] Hickle R., 2003, US Patent App, Patent No. 10208184
  • [4] Kamble V. V., 2001, P ICBME, P51
  • [5] Lee Paul, 2015, Br J Nurs, V24, pS30, DOI 10.12968/bjon.2015.24.Sup19.S30
  • [6] Laser-induced porous graphene films from commercial polymers
    Lin, Jian
    Peng, Zhiwei
    Liu, Yuanyue
    Ruiz-Zepeda, Francisco
    Ye, Ruquan
    Samuel, Errol L. G.
    Yacaman, Miguel Jose
    Yakobson, Boris I.
    Tour, James M.
    [J]. NATURE COMMUNICATIONS, 2014, 5
  • [7] Direct laser writing for creating porous graphitic structures and their use for flexible and highly sensitive sensor and sensor arrays
    Luo, Sida
    Phong Tran Hoang
    Liu, Tao
    [J]. CARBON, 2016, 96 : 522 - 531
  • [8] Mengli Wang, 2009, 2009 IEEE International Ultrasonics Symposium, P1355, DOI 10.1109/ULTSYM.2009.5441987
  • [9] Time domain reflectometry liquid level sensors
    Nemarich, CP
    [J]. IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2001, 4 (04) : 40 - 44
  • [10] Micromachined flow sensors - a review
    Nguyen, NT
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1997, 8 (01) : 7 - 16