Full-scale experimental study on combustion characteristics and smoke temperature of double-source fires in different tunnels

被引:0
|
作者
Guo, Chao [1 ,2 ]
Pan, Yihao [2 ]
Wang, Kai [2 ]
Zhou, Xifang [3 ]
Yan, Zhiguo [2 ]
机构
[1] Shanghai Normal Univ, Sch Civil Engn, Shanghai 201418, Peoples R China
[2] Tongji Univ, Dept Geotech Engn, Shanghai 200092, Peoples R China
[3] Shanghai Chengtou Highway Investment Grp Co Ltd, Shanghai 200335, Peoples R China
基金
中国国家自然科学基金;
关键词
Tunnel fire; Double-source fires; Full-scale tests; Flame tilt angle; Smoke temperature; POOL FIRES;
D O I
10.1016/j.firesaf.2024.104177
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Through a series of full-scale fire tests conducted in three different tunnels, the common characteristics of combustion and smoke temperature of double pool fires in actual operation tunnel environments are investigated. The evolution process of the coupling effects of shielding entrainment and thermal feedback enhancement is revealed. It is found that the ventilation state and the fire source spacing can alter the dominant relationship between the shielding entrainment effect and the thermal feedback enhancement effect, resulting in different evolution patterns of combustion characteristics and smoke flow patterns of double pool fires in tunnels. The heat release rate increases by 4 times when the double pool fire flames merge under the longitudinal ventilation compared with the double pool fire flames without fusion under the natural ventilation. The flame tilt angles of double pool fires were determined through the image processing method, and the prediction model of the flame inclination angle of downstream fire sources was established, considering fire source spacing. At the same time, the characteristic of temperature measured by Fiber Bragg Grating in double-source fire scenarios was investigated, developing a model to predict the longitudinal temperature rise distribution. It is found that the maximum temperature rise prediction model based on steady-state fire has poor applicability in the weak-plume fire scenario of full-scale tunnels. The analysis of the smoke flow patterns shows that the two-stage ventilation is more suitable for smoke control compared to full longitudinal ventilation in tunnel double-source fire accidents, especially for ensuring the safety of individuals trapped in the area between the two fire sources.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Full-Scale Experimental Study on Flexural Performance of the New Precast UHPC Diaphragm Slab in Utility Tunnels
    Cheng, Quan
    Li, Zhengwei
    Deng, Shaowei
    Jiang, Haibo
    Tian, Yueqiang
    Geng, Jiayue
    BUILDINGS, 2023, 13 (05)
  • [32] Full-scale tunnel fire experimental study of fire-induced smoke temperature profiles with methanol-gasoline blends
    Tian, Xiangliang
    Zhong, Maohua
    Shi, Congling
    Zhang, Peihong
    Liu, Chang
    APPLIED THERMAL ENGINEERING, 2017, 116 : 233 - 243
  • [33] Theoretical prediction model and full-scale experimental study of central smoke extraction with a uniform smoke rate in a tunnel fire
    Xu, P.
    Xing, R. J.
    Jiang, S. P.
    Li, L. J.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 86 : 63 - 74
  • [34] Field model experimental study on fire combustion and smoke temperature in very-high-altitude tunnels
    Wang, Feng
    Huang, Yubing
    Zhu, Lei
    Wang, Yu
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2020, 53 (03): : 114 - 120
  • [35] Full-scale modeling and experimental study of a gas neutron tube with a Penning ion source
    Rokhmanenkov, A.
    Mamedov, N.
    Kanshin, I.
    Maslennikov, S.
    Solodovnikov, A.
    JOURNAL OF APPLIED PHYSICS, 2024, 136 (13)
  • [36] Study on full-scale experimental and numerical investigation of fire-induced smoke control in an underground Double-Island Subway Station
    Li, Xueren
    Zhang, Liwei
    Shang, Bichen
    Fang, Xiang
    Tao, Yao
    Ma, Yin
    Wang, Yong
    Tu, Jiyuan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 163
  • [37] Full-scale experimental and numerical study on combustion behavior of upholstered sofa in ISO 9705 room
    Xu, L
    Mang, HP
    Yang, Y
    Wang, W
    Zhu, WB
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1287 - 1294
  • [38] Full-scale experimental study on fire characteristics induced by double fire sources in a two-lane road tunnel
    Guo, Chao
    Zhang, Tong
    Guo, Qinghua
    Yu, Tongsheng
    Fang, Zhongqiang
    Yan, Zhiguo
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 131
  • [39] Experimental study on fire characteristics of PC monitors-part II: Full-scale study under different ventilation conditions
    Shi, Long
    Chew, Michael
    Xie, Qiyuan
    Zhang, Ruifang
    Li, Liming
    Xu, Chunming
    Journal of Applied Fire Science, 2009, 19 (01): : 41 - 61
  • [40] Full-scale experimental study on suppressing lithium-ion battery pack fires from electric vehicles
    Cui, Yan
    Liu, Jianghong
    Han, Xin
    Sun, Shaohua
    Cong, Beihua
    FIRE SAFETY JOURNAL, 2022, 129