Bioelectrical impedance analysis for measuring body composition in an outpatient haemodialysis setting: a feasibility study

被引:1
|
作者
Gomes, Kristin [1 ,4 ]
Irwin, Chris [1 ,2 ]
Desbrow, Ben [2 ]
Roberts, Shelley [1 ,2 ,3 ]
机构
[1] Griffith Univ, Sch Hlth Sci & Social Work, Gold Coast Campus, Southport, Qld 4222, Australia
[2] Griffith Univ, Menzies Hlth Inst Queensland, Gold Coast Campus, Southport, Qld 4222, Australia
[3] Gold Coast Hosp & Hlth Serv, Allied Hlth Res, 1 Hosp Blvd, Southport, Qld 4219, Australia
[4] Griffith Univ, Room 2-59,Bldg G40,Gold Coast Campus, Southport, Qld 4222, Australia
关键词
feasibility; bioelectrical impedance; body composition; haemodialysis; malnutrition; MALNUTRITION; MUSCLE; MASS;
D O I
10.33235/rsaj.19.2.56-67
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Aim Clinical guidelines recommend using bioelectrical impedance analysis (BIA) to assess body composition in adults with renal failure on maintenance haemodialysis. This study evaluated the feasibility, acceptability and clinical utility of using BIA with haemodialysis outpatients. Methods Patients attending the haemodialysis outpatient unit at a tertiary public hospital in Australia were consecutively recruited. Participants completed a pre- and post-dialysis BIA measure and satisfaction survey about the measurement process. Primary outcomes pertained to feasibility (recruitment and measurement completion rates). Secondary outcomes included acceptability, assessed via patient satisfaction surveys, and predictive value of BIA for identifying malnutrition according to Subjective Global Assessment (SGA). Continuous variables were presented as mean +/- standard deviation (or median and interquartile range). Binomial logistic regression was performed to determine the predictive value of BIA for identifying malnutrition. Receiver operating characteristic curve analysis was used to evaluate BIA parameters for their ability to discriminate malnourished patients (determined by SGA) from well-nourished patients. Statistical significance was established at p<0.05.<br /> Results A total of 30 of 36 patients approached (83%) consented to participate, with 28 completing at least one BIA measurement and included in data analysis. BIA measurement completion rates were 93% and 87% pre- and postdialysis, respectively. Post-dialysis BIA measures of fat mass index, fat free mass index and skeletal muscle mass most closely reflected SGA-categorised malnutrition. Patients reported high acceptability for BIA, found the process easy, and valued the results. Conclusion BIA use in an outpatient haemodialysis unit is feasible and acceptable to patients, providing valuable objective data to enhance clinical practice.
引用
收藏
页码:56 / 67
页数:70
相关论文
共 50 条
  • [41] Prediction of body composition of Iberian pigs by means bioelectrical impedance
    Daza, A
    Mateos, A
    Ovejero, I
    Bote, CJL
    MEAT SCIENCE, 2006, 72 (01) : 43 - 46
  • [42] Body composition assessment by anthropometry and bioelectrical impedance
    Aristizabal, Juan Carlos
    Restrepo, Maria Teresa
    Estrada, Alejandro
    BIOMEDICA, 2007, 27 (02): : 216 - 224
  • [43] Body Composition Estimation and Agreement Analysis Between Bipolar and Tetrapolar Bioelectrical Impedance Analyzers
    Jambassi Filho, Jose Claudio
    Cyrino, Edilson Serpeloni
    Demantova Gurjao, Andre Luiz
    Braz, Igor Augusto
    Goncalves, Raquel
    Gobbi, Sebastiao
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2010, 16 (01) : 13 - 17
  • [44] Impact of eating and drinking on body composition measurements by bioelectrical impedance
    Androutsos, O.
    Gerasimidis, K.
    Karanikolou, A.
    Reilly, J. J.
    Edwards, C. A.
    JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2015, 28 (02) : 165 - 171
  • [45] Bioelectrical impedance vector analysis (BIVA) for the assessment of two-compartment body composition
    Buffa, R.
    Mereu, E.
    Comandini, O.
    Ibanez, M. E.
    Marini, E.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2014, 68 (11) : 1234 - 1240
  • [46] Bioelectrical impedance as a measure of change in body composition in young children
    Meredith-Jones, K. A.
    Williams, S. M.
    Taylor, R. W.
    PEDIATRIC OBESITY, 2015, 10 (04): : 252 - 259
  • [47] Comparison of bioelectrical impedance and DXA for measuring body composition among adults with Down syndrome
    Esco, Michael R.
    Nickerson, Brett S.
    Russell, Angela R.
    DISABILITY AND HEALTH JOURNAL, 2017, 10 (04) : 548 - 551
  • [48] Evaluation of Multifrequency Bioelectrical Impedance Analysis in Assessing Body Composition of Wrestlers
    Utter, Alan C.
    Lambeth, Pamela G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (02) : 361 - 367
  • [49] Body composition in underweight elderly subjects: reliability of bioelectrical impedance analysis
    Lupoli, L
    Sergi, G
    Coin, A
    Perissinotto, E
    Volpato, S
    Busetto, L
    Inelmen, EM
    Enzi, G
    CLINICAL NUTRITION, 2004, 23 (06) : 1371 - 1380
  • [50] Agreement between vector analysis and body composition measurements by four types of bioelectrical impedance technology in hemodialysis patients
    Espinosa-Cuevas, Angeles
    Ch-Duran, Larisa-Ximena
    Atilano-Carsi, Ximena
    Gonzalez-Ortiz, Ailema
    Ramos-Acevedo, Samuel
    Lopez-Cisneros, Sonia
    Correa-Rotter, Ricardo
    Vanessa Miranda-Alatriste, Paola
    NUTRICION HOSPITALARIA, 2022, 39 (05) : 1047 - 1057