Conceptual design of visible spectroscopy diagnostics for DTT

被引:0
|
作者
Belpane, A. [1 ,2 ]
Carraro, L. [1 ,3 ]
Fassina, A. [6 ]
Cavedon, M. [4 ]
Senni, L. [5 ]
机构
[1] Univ Padua, Consorzio RFX CNR, ENEA, INFN,Acciaierie Venete SpA, Corso Stati Uniti 4, I-35127 Padua, Italy
[2] Univ Tuscia, Dept Econ Engn Soc & Business Org, I-01100 Viterbo, Italy
[3] CNR ISTP, Via Corso Stati Uniti 4, I-35127 Padua, Italy
[4] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Milan, Italy
[5] CNR, Inst Appl Math Mauro Picone IAC, I-00185 Rome, Italy
[6] ENEA, Fus & Nucl Safety Dept, I-00044 Frascati, Italy
关键词
diagnostics; DTT; effective charge; visible spectroscopy; ASDEX UPGRADE; BREMSSTRAHLUNG; Z(EFF);
D O I
10.1088/1361-6587/ad5378
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The project of the Visible Spectroscopy diagnostics for the Z eff radial profile measurement and for the divertor visible imaging spectroscopy, designed for the new tokamak DTT (Divertor Tokamak Test), is presented. To deal with the geometrical constraints of DTT and to minimize the diagnostics volume inside the access port, an integrated and compact solution hosting the two systems has been proposed. The Z eff radial profile will be evaluated from the Bremsstrahlung radiation measurement in the visible spectral range, acquiring light along ten Lines of Sight (LoS) in the upper part of the poloidal plane. The plasma emission will be focused on optical fibers, which will carry it to the spectroscopy laboratory. A second equipment, with a single toroidal LoS crossing the plasma centre and laying on the equatorial plane, will measure the average Z eff on a longer path, minimizing the incidental continuum spectrum contaminations by lines/bands emitted from the plasma edge. The divertor imaging system is designed to measure impurity and main gas influxes, to monitor the plasma position and kinetics of impurities, and to follow the plasma detachment evolution. The project aims at obtaining the maximum coverage of the divertor region. The collected light can be shared among different spectrometers and interferential filter devices placed outside the torus hall to easily change their setup. The system is composed of two telescopes, an upper and a lower one, allowing both a perpendicular and a tangential view of the DTT divertor region. This diagnostic offers a unique and compact solution designed to cope the demanding constraints of this next-generation tokamak fusion devices, integrating essential tools for wide-ranging impurity characterization and versatile investigation of divertor physics.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Systems engineering approach for the iterative concept design and virtual simulation of the DTT hyper redundant manipulator
    Buonocore, Sara
    Di Gironimo, Giuseppe
    Favaretto, Mauro
    Grasso, Tiberio
    Zanon, Fabio
    Grazioso, Stanislao
    FUSION ENGINEERING AND DESIGN, 2023, 190
  • [42] RFLP Approach to DTT Divertor Fixation System Design Using the 3DExperience Platform
    Lanzotti, Francesca Giovanna
    Marzullo, Domenico
    Di Gironimo, Giuseppe
    DESIGN TOOLS AND METHODS IN INDUSTRIAL ENGINEERING III, VOL 2, ADM 2023, 2024, : 289 - 297
  • [43] Requirements and interface management for the divertor system design and integration in the Divertor Tokamak Test (DTT) facility
    Tenaglia, Giovanni
    Romanelli, Francesco
    La Rovere, Stefano
    Polli, Gian Mario
    Roccella, Selanna
    Ramogida, Giuseppe
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [44] Calibration of toroidal visible bremsstrahlung diagnostics and reconstruction of effective charge profiles in Korea Superconducting Tokamak Advanced Research (KSTAR)
    Jang, Juhyeok
    Seo, Dongcheol
    Lee, Jong-Ha
    Kim, Ha Jin
    Lee, Jekil
    Ko, Won-Ha
    Nam, Yong Un
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (01)
  • [45] Creating novel medical diagnostics with a design for manufacturing
    Kumar, Ashok A.
    TRANSLATIONAL MATERIALS RESEARCH, 2018, 5 (02):
  • [46] The Use of Spectral Ellipsometry and Raman Spectroscopy in Screening Diagnostics of Colorectal Cancer
    Kruchinin, V. N.
    Kruchinina, M. V.
    Prudnikova, Ya. I.
    Spesivtsev, E. V.
    Rykhlitskii, S. V.
    Volodin, V. A.
    Shekhovtsov, S. V.
    Pel'tek, S. E.
    OPTICS AND SPECTROSCOPY, 2019, 127 (01) : 170 - 176
  • [47] Quantitative diagnostics of a methane/air mini-flame by Raman spectroscopy
    Fernández, JM
    Punge, A
    Tejeda, G
    Montero, S
    JOURNAL OF RAMAN SPECTROSCOPY, 2006, 37 (1-3) : 175 - 182
  • [48] Diagnostics of lighting Arc plasmas by non-LTE emission spectroscopy
    Karabourniotis, D
    Drakakis, E
    HIGH TEMPERATURE MATERIAL PROCESSES, 2004, 8 (04): : 535 - 547
  • [49] Raman Spectroscopy Enables Confirmatory Diagnostics of Fusarium Wilt in Asymptomatic Banana
    Parlamas, Stephen
    Goetze, Paul K.
    Humpal, Dillon
    Kurouski, Dmitry
    Jo, Young-Ki
    FRONTIERS IN PLANT SCIENCE, 2022, 13
  • [50] Marine Engine Oil Diagnostics by Means of NMR Spectroscopy and Relaxometry of Protons
    Sinyavsky, Nikolay
    Mershiev, Ivan