Load frequency control of a three-area power system based on the optimal tuning of a fractional-order proportional-integral- derivative controller with multi-objective gray wolf optimization

被引:1
作者
Ayyappan, B. Prakash [1 ]
Thanigaiselvan, R. [2 ]
Prabakaran, R. [2 ]
Kanimozhi, R. [2 ]
机构
[1] Sri Bharathi Engn Coll Women, Dept Elect & Elect Engn, Kaikkurichi 622303, Pudukkottai, India
[2] Anna Univ, Univ Coll Engn, Dept Elect & Elect Engn, BIT Campus, Tiruchirappalli 620024, Tamil Nadu, India
来源
JOURNAL OF ENGINEERING RESEARCH | 2023年 / 11卷 / 2B期
关键词
Load Frequency Control; Fractional-Order Proportional-Integral-Derivative Controllers; Fire Fly Algorithm; Multi-Objective Gray Wolf Optimization Algorithms; FUZZY-PID CONTROLLER; GENETIC ALGORITHM; DESIGN;
D O I
10.36909/jer.13689
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In an interconnected electrical power system, load frequency control is the most important ancillary service that is essential for maintaining electrical system reliability at an adequate level. Herein, a multi -objective gray wolf optimization (MOGWO) algorithm was introduced to maintain balance between the exploitation and exploration stages and provide the best fitness value. During a disturbance in the output of the system, optimization was implemented using the firefly algorithm (FFA) and MOGWO, which were carefully tuned, and the parameters were compared with those of the three -area three -source model of the power system. A fractional -order proportional-integral-derivative (FOPID) controller is a PID controller whose derivative and integral orders are fractions rather than integers. The FOPID controller supports the improved stability of the designed model with controlled deviations in the frequency and grid tie -line power. In this study, the optimal tuning of the parameters of controllers, such as PI, PID, and FOPID, in the power system was done to regulate the frequency in the multiarea multi -source model designed with hydro -thermal -gas generation units. The output performance of the proposed model was estimated based on the simulation results using the MATLAB-SIMULINK tool. The dynamic performance of the system was examined by introducing step -load perturbations of 1% or 2% in one area. Sensitivity analysis revealed that the FFA and MOGWO optimized the FOPID controller parameters obtained under nominal conditions of loading, size, and position of disturbance. The system parameters remained robust and did not require to be reset even with significant changes in the system. The simulation results demonstrated the effectiveness of the FOPID controller in the presence and absence of the FF and MOGWO algorithms. Additionally, the MOGWO algorithm was executed appropriately and led to improved performance in terms of metrics, such as overshoot, undershoot, and settling time.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 22 条
[1]   A New Metaheuristic Algorithm Based on Shark Smell Optimization [J].
Abedinia, Oveis ;
Amjady, Nima ;
Ghasemi, Ali .
COMPLEXITY, 2016, 21 (05) :97-116
[2]  
Anbarasi S, 2016, CONTROL ENG APPL INF, V18, P20
[3]   Design and analysis of the performance of multi-source interconnected electrical power system using resilience random variance reduction technique [J].
Ayyappan, B. prakash ;
Kanimozhi, R. .
BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2021, 69 (05)
[4]  
Ayyappan B. Prakash, 2021, Science, Technology and Development, V10, P153
[5]   Multivariable predictive control considering time delay for load-frequency control in multi-area power systems [J].
Daniar, Sabah ;
Shiroei, Mojtaba ;
Aazami, Rahmat .
ARCHIVES OF CONTROL SCIENCES, 2016, 26 (04) :527-549
[6]   Load frequency control problem in interconnected power systems using robust fractional PIλD controller [J].
Delassi, Abdelmoumene ;
Arif, Salem ;
Mokrani, Lakhdar .
AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (01) :77-88
[7]  
Fakharian A, 2016, CONTROL ENG APPL INF, V18, P107
[8]   Multiverse optimized fuzzy-PID controller with a derivative filter for load frequency control of multisource hydrothermal power system [J].
Kumar, Amit ;
Suhag, Sathans .
TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (05) :4187-+
[9]   Design of Fractional Order PID Controller for Load Frequency Control in Perturbed Two Area Interconnected System [J].
Lamba, Ruchika ;
Singla, Sunil Kumar ;
Sondhi, Swati .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2019, 47 (11-12) :998-1011
[10]   Constrained population extremal optimization-based robust load frequency control of multi-area interconnected power system [J].
Lu, Kangdi ;
Zhou, Wuneng ;
Zeng, Guoqiang ;
Zheng, Yiyuan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 105 :249-271