Balancing robustness and adaptation rate for proton therapy of lung cancer patients

被引:1
作者
Badiu, Vlad [1 ,2 ]
Taasti, Vicki Trier [3 ]
Defraene, Gilles [1 ]
van Elmpt, Wouter [3 ]
Sterpin, Edmond [1 ,2 ,4 ]
机构
[1] Katholieke Univ Leuven, Dept Oncol, Lab Expt Radiotherapy, Leuven, Belgium
[2] UZ Leuven, Particle Therapy Interuniv Ctr Leuven PARTICLE, Leuven, Belgium
[3] Maastricht Univ, Med Ctr, GROW Sch Oncol & Reprod, Dept Radiat Oncol Maastro, Maastricht, Netherlands
[4] Catholic Univ Louvain, Inst Rech Expt & Clin, Ctr Mol Imaging Radiotherapy & Oncol MIRO, Brussels, Belgium
关键词
Proton therapy; Adaptation; Robustness; Lung cancer; CLINICAL IMPLEMENTATION; OPTIMIZATION; MOTION; PLANS;
D O I
10.1016/j.radonc.2024.110290
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: An increase in plan robustness leads to a higher dose to organs-at-risk (OARs), and an increased chance of post-treatment toxicities. In contrast, more conformal plans lead to sparing of healthy surrounding tissue at the expense of a higher sensitivity to anatomical changes, requiring costly adaptations. In this study, we assess the trade-off and impact of treatment plan robustness on the adaptation rate. Method: Treatment planning was performed for 40 lung cancer patients, each having a planning 4DCT and up to eight weekly repeated 4DCTs (reCTs). For each patient, plans were made with three different levels of robustness based on setup uncertainty of 3, 6 and 9 mm. These plans were robustly re-evaluated on all reCTs to assess whether the clinical constraints were met. Results: For the 3, 6 and 9 mm robustness levels, adaptation rates of 87.5 %, 70.0 % and 57.5 %, respectively, were observed. A mean absolute normal tissue complication probability (NTCP) gain of 2.9 percentage points (pp) was calculated for pneumonitis grade >= 2 when transitioning from 9 mm plans to 3 mm plans, 7.6 pp for esophagitis grade >= 2, and 2.5 pp for mortality risk 2 years post-treatment. Conclusion: The lowered risk of post treatment toxicities at lower robustness levels is clinically relevant but comes at the expense of more treatment adaptations, particularly in cases where meeting our clinical goals is not compromised by having a dose that is more conformal to the target. The trade-off between workload and reduced NTCP needs to be individually assessed.
引用
收藏
页数:6
相关论文
共 22 条
  • [1] [Anonymous], 2019, Landelijk Indicatie Protocol Protonen Therapie Longcarcinoom
  • [2] Improved healthy tissue sparing in proton therapy of lung tumors using statistically sound robust optimization and evaluation
    Badiu, Vlad
    Souris, Kevin
    Buti, Gregory
    Villarroel, Elena Borderias
    Lambrecht, Maarten
    Sterpin, Edmond
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 96 : 62 - 69
  • [3] XFeasibility of online IMPT adaptation using fast, automatic and robust dose restoration
    Bernatowicz, Kinga
    Geets, Xavier
    Barragan, Ana
    Janssens, Guillaume
    Souris, Kevin
    Sterpin, Edmond
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (08)
  • [4] Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee
    Chang, Joe Y.
    Zhang, Xiaodong
    Knopf, Antje
    Li, Heng
    Mori, Shinichiro
    Dong, Lei
    Lu, Hsiao-Ming
    Liu, Wei
    Badiyan, Shahed N.
    Both, Stephen
    Meijers, Arturs
    Lin, Liyong
    Flampouri, Stella
    Li, Zuofeng
    Umegaki, Kikuo
    Simone, Charles B., II
    Zhu, Xiaorong R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (01): : 41 - 50
  • [5] Clinical Implementation of Intensity Modulated Proton Therapy for Thoracic Malignancies
    Chang, Joe Y.
    Li, Heng
    Zhu, X. Ronald
    Liao, Zhongxing
    Zhao, Lina
    Liu, Amy
    Li, Yupeng
    Sahoo, Narayan
    Poenisch, Falk
    Gomez, Daniel R.
    Wu, Richard
    Gillin, Michael
    Zhang, Xiaodong
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (04): : 809 - 818
  • [6] GPU-accelerated Monte Carlo-based online adaptive proton therapy: A feasibility study
    Feng, Hongying
    Patel, Samir H.
    Wong, William W.
    Younkin, James E.
    Penoncello, Gregory P.
    Morales, Danairis Hernandez
    Stoker, Joshua B.
    Robertson, Daniel G.
    Fatyga, Mirek
    Bues, Martin
    Schild, Steven E.
    Foote, Robert L.
    Liu, Wei
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : 3550 - 3563
  • [7] Feasibility of Pencil Beam Scanned Intensity Modulated Proton Therapy in Breath-hold for Locally Advanced Non-Small Cell Lung Cancer
    Gorgisyan, Jenny
    af Rosenschold, Per Munck
    Perrin, Rosalind
    Persson, Gitte F.
    Josipovic, Mirjana
    Belosi, Maria Francesca
    Engelholm, Svend Aage
    Weber, Damien C.
    Lomax, Antony J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (05): : 1121 - 1128
  • [8] Adaptation is mandatory for intensity modulated proton therapy of advanced lung cancer to ensure target coverage
    Hoffmann, Lone
    Alber, Markus
    Jensen, Maria Fuglsang
    Holt, Marianne Ingerslev
    Moller, Ditte Sloth
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 122 (03) : 400 - 405
  • [9] Energy layer optimization strategies for intensity-modulated proton therapy of lung cancer patients
    Jensen, M. Fuglsang
    Hoffmann, L.
    Petersen, J. B. B.
    Moller, D. S.
    Alber, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (10) : 4355 - 4363
  • [10] Adaptive/Nonadaptive Proton Radiation Planning and Outcomes in a Phase II Trial for Locally Advanced Non-small Cell Lung Cancer
    Koay, Eugene J.
    Lege, David
    Mohan, Radhe
    Komaki, Ritsuko
    Cox, James D.
    Chang, Joe Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (05): : 1093 - 1100