The behavior of concrete filled steel tubular columns infilled with high-strength geopolymer recycled aggregate concrete

被引:4
|
作者
Al-Rousan, Rajai Z. [1 ]
Sawalha, Haneen M. [1 ]
机构
[1] Jordan Univ Sci & Technol, Fac Engn, Dept Civil Engn, POB 3030, Irbid 22110, Jordan
关键词
CFST column; geopolymer concrete; high-strength; NLFEA; recycled aggregate; STUB COLUMNS; COMPRESSIVE BEHAVIOR; CIRCULAR CFST; PERFORMANCE; SQUARE; TUBES; SECTIONS;
D O I
10.12989/scs.2024.51.6.661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The utilization of geopolymer recycled aggregate concrete (GRAC) as the infilled core of the concrete-filled steel tubular (CFST) columns provides superior economic and environmental benefits. However, limited research exists within the field of geopolymer recycled aggregate concrete considered a green and sustainable material, in addition to the limitation of the design guidelines to predict the behavior of such an innovative new material combination. Moreover, the behavior of high-strength concrete is different from the normal-strength one, especially when there is another material of high-strength properties, such as the steel tube. This paper aims to investigate the behavior of the axially loaded square high-strength GRACFST columns through the nonlinear finite element analysis (NLFEA). A total of thirty-two specimens were simulated using ABAQUS/Standard software with three main variables: recycled aggregate replacement ratio (0, 30, and 50) %, width-to-thickness ratios (52.0, 32.0, 23.4, and 18.7), and length-to-width ratio (3, 5, 9, and 12). During the analysis, the response in terms of the axial load versus the longitudinal strain was recorded and plotted. In addition, various mechanical properties were calculated and analyzed. In view of the results, it has been demonstrated that the mechanical properties of high-strength GRACFST columns such as ultimate load-bearing capacity, compressive stiffness, energy absorption capacity, and ductility increase with the increase of the steel tube thickness owing to the improvement of the confinement effect of the steel tube. In contrast, the incorporation of the recycled aggregate adversely affected the mentioned properties except the ductility, while the increase of the recycled aggregate replacement ratio improved the column's ductility. Moreover, it has been found that the increase in the length-to-width ratio significantly reduced both the failure strain and the energy absorption capacity. Finally, the obtained NLFEA results of the ultimate load-bearing capacity were compared with the corresponding predicted capacities by numerous codes. It has been concluded that AISC, ACI, and EC give conservative predictions for the ultimate load-bearing capacity since the confinement effect was not considered by these codes.
引用
收藏
页码:661 / 678
页数:18
相关论文
共 50 条
  • [31] Experimental Behavior and Design of High-Strength Circular Concrete-Filled Steel Tube Short Columns
    Wei, Jiangang
    Luo, Xia
    Lai, Zhichao
    Varma, Amit H.
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (01)
  • [32] Code based assessment of load capacity of steel tubular columns infilled with recycled aggregate concrete under compression
    Kadhim, Ihsan Taha
    Guneyisi, Esra Mete
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 168 : 715 - 731
  • [33] High-strength concrete-filled steel tube columns with tie bars: Seismic behavior and design
    Hu, Hong-Song
    Tan, Yue-Yue
    Xu, Li
    Basha, Syed Humayun
    Ji, Xiang-Ru
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 212
  • [34] Experimental and Analytical Research on Flexural Behavior of Concrete-Filled High-Strength Steel Tubular Members
    Zhang, Zai-Yu
    Sun, Qing
    Wang, Jia-Qi
    Zhao, Chao
    Zhao, Bing-Zhen
    Wang, Jian-Tao
    MATERIALS, 2022, 15 (11)
  • [35] Behaviour of steel tubular members infilled with ultra high strength concrete
    Xiong, Ming-Xiang
    Xiong, De-Xin
    Liew, J. Y. Richard
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 138 : 168 - 183
  • [36] Behaviour of recycled aggregate concrete filled stainless steel stub columns
    Tam, Vivian W. Y.
    Wang, Zhi-Bin
    Tao, Zhong
    MATERIALS AND STRUCTURES, 2014, 47 (1-2) : 293 - 310
  • [37] Behavior of Rectangular-Sectional Steel Tubular Columns Filled with High-Strength Steel Fiber Reinforced Concrete Under Axial Compression
    Liu, Shiming
    Ding, Xinxin
    Li, Xiaoke
    Liu, Yongjian
    Zhao, Shunbo
    MATERIALS, 2019, 12 (17)
  • [38] Transverse impact behavior of high-strength concrete filled normal-/high-strength square steel tube columns
    Yang, Xiaoqiang
    Yang, Hua
    Zhang, Sumei
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2020, 139
  • [39] Compressive behavior of geopolymer recycled brick aggregate concrete confined by steel tubes
    Zheng, Yongqian
    Du, Jiangtao
    Zheng, Liya
    Wang, Cunhua
    JOURNAL OF BUILDING ENGINEERING, 2023, 70
  • [40] Experimental study of eccentrically loaded high-strength concrete filled circular high-strength steel tubular columns after fire exposure
    Du, Tao
    Liu, Faqi
    Yang, Hua
    Li, Ying
    Li, Yinglong
    THIN-WALLED STRUCTURES, 2025, 210