Assessing of the punching capability of developed slab-column connections in precast concrete flat slabs

被引:0
作者
Nasr, Ahmed A. [1 ,2 ]
Hussein, Yehia A. [3 ]
Yehia, Nabil A. B. [4 ]
El-Kashif, Khaled F. [4 ]
机构
[1] Tsinghua Univ, State Key Lab Hydrosci & Engn, Beijing 100084, Peoples R China
[2] Natl Water Res Ctr, Construct Res Inst, Cairo, Egypt
[3] Inst Concrete Struct, Housing & Bldg Res Ctr, Cairo, Egypt
[4] Cairo Univ, Fac Engn, Dept Concrete Struct, Giza, Egypt
关键词
punching shear; load capacity; precast concrete structures; slab column connection; flat slab; SEISMIC PERFORMANCE; SHEAR RESISTANCE; BEHAVIOR;
D O I
10.1504/IJSTRUCTE.2024.138114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Punching capacity and failure behaviour of developed slab-column connections of precast concrete structures are investigated in this work. The experiments were implemented on the interior column of a residential flat slab, using four connections of full scale compared to the prototype connection. The configuration and erection methods are regarded the most important parameters, as they are classified as concrete corbel, steel corbel, dowels, Indo, and prototype. The results revealed that, the ultimate loads attained by the concrete corbel connection, steel corbel connection, and dowels connection exceeded the load attained by the prototype connection. Furthermore, increasing the axial loading area increases punching failure resistance and load capacity. Additionally, the steel reinforcement is essential since it participates in punching opposition. Lastly, it was reached that dowels and concrete corbel connections can be used for only one story, while the steel bracket, and Indo connections can be utilised on multiple slab floors.
引用
收藏
页码:141 / 163
页数:24
相关论文
共 42 条
  • [1] Design of biaxially loaded external slab column connections
    Abu-Salma, Deema
    Vollum, Robert L.
    Macorini, Lorenzo
    [J]. ENGINEERING STRUCTURES, 2021, 249
  • [2] Punching behaviour of RC flat slabs under reversed horizontal cyclic loading
    Almeida, Andre F. O.
    Inacio, Micael M. G.
    Lucio, Valter J. G.
    Ramos, Antonio Pinho
    [J]. ENGINEERING STRUCTURES, 2016, 117 : 204 - 219
  • [3] Punching shear strengthening of flat slabs with EBROG and EBRIG - FRP strips
    Amiri, Somayeh
    Talaeitaba, Sayed Behzad
    [J]. STRUCTURES, 2020, 26 : 139 - 155
  • [4] Punching shear tests on flat concrete slabs exposed to fire
    Annerel, E.
    Lu, L.
    Taerwe, L.
    [J]. FIRE SAFETY JOURNAL, 2013, 57 : 83 - 95
  • [5] ASTM C., 2022, Annual Book of ASTM Standards, V150, P4
  • [6] Beeby AW., 1995, Designers' Handbook to Eurocode 2: 1. Design of concrete structures
  • [7] Evaluation of compressive membrane action effects on punching shear resistance of reinforced concrete slabs
    Belletti, Beatrice
    Walraven, Joost C.
    Trapani, Francesco
    [J]. ENGINEERING STRUCTURES, 2015, 95 : 25 - 39
  • [8] Experimental study on two innovative ductile moment-resisting precast concrete beam-column connections
    Beni, M. B. Tadi
    Madhkhan, M.
    [J]. STRUCTURES, 2022, 39 : 559 - 572
  • [9] Experimental and numerical investigation on seismic performance of a composite wide beam-column interior joint
    Bohara, Rajendra Prasad
    Tanapornraweekit, Ganchai
    Tangtermsirikul, Somnuk
    [J]. STRUCTURES, 2021, 30 : 560 - 573
  • [10] Bompa DV, 2010, SCI B SERIES MIN MIN, V24, P111