Biomechanical Design Optimization of Distal Humerus Fracture Plates: A Review

被引:1
作者
Zdero, Radovan [1 ]
Brzozowski, Pawel [1 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] Victoria Hosp, Orthopaed Biomech Lab, London, ON, Canada
[2] Western Univ, Div Orthopaed Surg, London, ON, England
关键词
biomechanics; distal humerus; fracture; optimization; plates; review; INTERNAL-FIXATION; PLATING SYSTEMS; LOCKING PLATES; PROPHYLACTIC FIXATION; RECONSTRUCTION PLATES; PROXIMAL HUMERUS; IMPLANT FAILURE; BONE; PARALLEL; STABILITY;
D O I
10.1155/2024/6015794
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The goal of this article was to review studies on distal humerus fracture plates (DHFPs) to understand the biomechanical influence of systematically changing the plate or screw variables. The problem is that DHFPs are commonly used surgically, although complications can still occur, and it is unclear if implant configurations are always optimized using biomechanical criteria. A systematic search of the PubMed database was conducted to identify English-language biomechanical optimization studies of DHFPs that parametrically altered plate and/or screw variables to analyze their influence on engineering performance. Intraarticular and extraarticular fracture (EAF) data were separated and organized under commonly used biomechanical outcome metrics. The results identified 52 eligible DHFP studies, which evaluated various plate and screw variables. The most common plate variables evaluated were geometry, hole type, number, and position. Fewer studies assessed screw variables, with number and angle being the most common. However, no studies examined nonmetallic materials for plates or screws, which may be of interest in future research. Also, articles used various combinations of biomechanical outcome metrics, such as interfragmentary fracture motion, bone, plate, or screw stress, number of loading cycles to failure, and overall stiffness (Os) or failure strength (Fs). However, no study evaluated the bone stress under the plate to examine bone "stress shielding," which may impact bone health clinically. Surgeons treating intraarticular and extraarticular distal humerus fractures should seriously consider two precontoured, long, thick, locked, and parallel plates that are secured by long, thick, and plate-to-plate screws that are located at staggered levels along the proximal parts of the plates, as well as an extra transfracture plate screw. Also, research engineers could improve new studies by perusing recommendations in future work (e.g., studying alternative nonmetallic materials or "stress shielding"), clinical ramifications (e.g., benefits of locked plates), and study quality (e.g., experimental validation of computational studies).
引用
收藏
页数:14
相关论文
共 50 条
[41]   Paediatric T-condylar fracture of distal humerus: a systematic review and meta-analysis [J].
Prajapati, Sushil ;
Meena, Omprakash ;
Patralekh, Mohit Kumar ;
Viswanathan, Vibhu Krishnan ;
Kumar, Deepak ;
Jain, Vijay Kumar .
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2025, 34 (05) :444-452
[42]   Comparison of treatments in patients with distal humerus intercondylar fracture: a systematic review and meta-analysis [J].
Chen, Hongwei ;
Li, Dacheng ;
Zhang, Jun ;
Xiong, Xinwei .
ANNALS OF MEDICINE, 2017, 49 (07) :613-625
[43]   Ellbow fracture in old age - receipt or replacement?Distal Humerus Fracture in the Elderly [J].
Plath, Johannes E. ;
Foerch, Stefan ;
Haufe, Thomas ;
Mayr, Edgar Johann .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2018, 156 (01) :30-40
[44]   Intramedullary nailing at different distal tibial fracture levels: A biomechanical study [J].
Guran, Ortac ;
Ozmanevra, Ramadan ;
Husemoglu, Resit Bugra ;
Havitcioglu, Hasan ;
Altinoz, Ozenc .
MEDICINE, 2024, 103 (22) :E38353
[45]   Surgical Exposures for Distal Humerus Fractures: A Review [J].
Pollock, J. Whitcomb ;
Athwal, George S. ;
Steinmann, Scott P. .
CLINICAL ANATOMY, 2008, 21 (08) :757-768
[46]   Minimally invasive stabilization of distal humerus fractures: A pilot study with biomechanical evaluation [J].
Reising, K. ;
Konstantinidis, L. ;
Helwig, P. ;
Wagner, F. C. L. ;
Suedkamp, N. P. ;
Strohm, P. C. .
TECHNOLOGY AND HEALTH CARE, 2014, 22 (06) :909-913
[47]   Epithelioid Hemangioma of the Distal Humerus With Pathologic Fracture [J].
Kleck, Christopher J. ;
Seidel, Matthew J. .
ORTHOPEDICS, 2012, 35 (01) :E116-E119
[48]   Are two plates necessary for extraarticular fractures of the distal humerus? [J].
Watson, Jeffrey D. ;
Kim, Hyunchul ;
Becker, Edward H. ;
Shorofsky, Michael ;
Lerman, Daniel ;
O'Toole, Robert V. ;
Eglseder, W. Andrew ;
Murthi, Anand M. .
CURRENT ORTHOPAEDIC PRACTICE, 2014, 25 (05) :462-466
[49]   A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model [J].
Alluri, Ram K. ;
Bougioukli, Sofia ;
Stevanovic, Milan ;
Ghiassi, Alidad .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09) :748.e1-748.e8
[50]   Treatment of Distal Humerus Articular Fracture with Pin-and-Plate Technique [J].
Abdoli, Abbas ;
Farhoud, Amir Reza ;
Kamrani, Reza Shahryar .
JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (03) :332-339