Biomechanical Design Optimization of Distal Humerus Fracture Plates: A Review

被引:1
作者
Zdero, Radovan [1 ]
Brzozowski, Pawel [1 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] Victoria Hosp, Orthopaed Biomech Lab, London, ON, Canada
[2] Western Univ, Div Orthopaed Surg, London, ON, England
关键词
biomechanics; distal humerus; fracture; optimization; plates; review; INTERNAL-FIXATION; PLATING SYSTEMS; LOCKING PLATES; PROPHYLACTIC FIXATION; RECONSTRUCTION PLATES; PROXIMAL HUMERUS; IMPLANT FAILURE; BONE; PARALLEL; STABILITY;
D O I
10.1155/2024/6015794
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The goal of this article was to review studies on distal humerus fracture plates (DHFPs) to understand the biomechanical influence of systematically changing the plate or screw variables. The problem is that DHFPs are commonly used surgically, although complications can still occur, and it is unclear if implant configurations are always optimized using biomechanical criteria. A systematic search of the PubMed database was conducted to identify English-language biomechanical optimization studies of DHFPs that parametrically altered plate and/or screw variables to analyze their influence on engineering performance. Intraarticular and extraarticular fracture (EAF) data were separated and organized under commonly used biomechanical outcome metrics. The results identified 52 eligible DHFP studies, which evaluated various plate and screw variables. The most common plate variables evaluated were geometry, hole type, number, and position. Fewer studies assessed screw variables, with number and angle being the most common. However, no studies examined nonmetallic materials for plates or screws, which may be of interest in future research. Also, articles used various combinations of biomechanical outcome metrics, such as interfragmentary fracture motion, bone, plate, or screw stress, number of loading cycles to failure, and overall stiffness (Os) or failure strength (Fs). However, no study evaluated the bone stress under the plate to examine bone "stress shielding," which may impact bone health clinically. Surgeons treating intraarticular and extraarticular distal humerus fractures should seriously consider two precontoured, long, thick, locked, and parallel plates that are secured by long, thick, and plate-to-plate screws that are located at staggered levels along the proximal parts of the plates, as well as an extra transfracture plate screw. Also, research engineers could improve new studies by perusing recommendations in future work (e.g., studying alternative nonmetallic materials or "stress shielding"), clinical ramifications (e.g., benefits of locked plates), and study quality (e.g., experimental validation of computational studies).
引用
收藏
页数:14
相关论文
共 50 条
[21]   Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study [J].
Osada, D ;
Viegas, SF ;
Shah, MA ;
Morris, RP ;
Patterson, RM .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01) :94-104
[22]   A scoping review of biomechanical testing for proximal humerus fracture implants [J].
David Cruickshank ;
Kelly A. Lefaivre ;
Herman Johal ;
Norma J. MacIntyre ;
Sheila A. Sprague ;
Taryn Scott ;
Pierre Guy ;
Peter A. Cripton ;
Michael McKee ;
Mohit Bhandari ;
Gerard P. Slobogean .
BMC Musculoskeletal Disorders, 16
[23]   A scoping review of biomechanical testing for proximal humerus fracture implants [J].
Cruickshank, David ;
Lefaivre, Kelly A. ;
Johal, Herman ;
MacIntyre, Norma J. ;
Sprague, Sheila A. ;
Scott, Taryn ;
Guy, Pierre ;
Cripton, Peter A. ;
Mckee, Michael ;
Bhandari, Mohit ;
Slobogean, Gerard P. .
BMC MUSCULOSKELETAL DISORDERS, 2015, 16
[24]   Evaluation of stabilization of intra-articular fracture of distal humerus - finite element study [J].
Kruszewski, Artur ;
Piszczatowski, Szczepan ;
Piekarczyk, Piotr ;
Kwiatkowski, Krzysztof .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2020, 22 (01) :153-163
[25]   Biomechanical Comparative Analyses Between the Anterolateral and Medial Distal Tibia Locking Plates in Treating Complex Distal Tibial Fracture: A Finite Element Study [J].
Aizat, Raja Mohd ;
Kadir, Mohammed Rafiq Abdul ;
Ab Rahman, Shaifuzain ;
Shihabudin, Tengku Muzaffar Tengku Md ;
Robson, Noorzurani ;
Kamarul, Tunku .
JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) :532-537
[26]   Trends in the Characterization of the Proximal Humerus in Biomechanical Studies: A Review [J].
Castro-Franco, Angel D. ;
Mendoza-Munoz, Ismael ;
Gonzalez-Angeles, Alvaro ;
Cruz-Sotelo, Samantha E. ;
Castaneda, Ana Maria ;
Siqueiros-Hernandez, Miriam .
APPLIED SCIENCES-BASEL, 2020, 10 (18)
[27]   Elbow dislocation and articular fracture of the distal humerus [J].
Andrs Arizmendi ;
Santiago LozanoCaldern ;
Danid CRing ;
Jesse BJupiter .
中华创伤骨科杂志, 2006, (09) :801-805
[28]   Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study [J].
Sherif Galal ;
Yasser Mattar ;
Alaa Mohy Eldin Solyman ;
Mostafa Ezzat .
International Orthopaedics, 2020, 44 :2761-2767
[29]   Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment [J].
Reina-Romo, Esther ;
Giraldez-Sanchez, M. A. ;
Mora-Macias, J. ;
Cano-Luis, P. ;
Dominguez, Jaime .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (10) :1043-1052
[30]   Biomechanical study of different plate configurations for distal humerus osteosynthesis [J].
M. Bogataj ;
F. Kosel ;
R. Norris ;
M. Krkovic ;
M. Brojan .
Medical & Biological Engineering & Computing, 2015, 53 :381-392