Digital fabrication of polyetheretherketone retentive bar attachment inserts as overdenture maintenance: A dental technique

被引:6
作者
Abdelaziz, Medhat Sameh [1 ]
Tella, Eman Abd El Sattar Abd El Megid [2 ]
机构
[1] Future Univ Egypt, Fac Oral & Dent Med, Dept Prosthodont, End 90 St, Cairo, Egypt
[2] Umm Al Qura Univ, Coll Dent, Dept Basic & Clin Oral Sci, Periodontol, Mecca, Saudi Arabia
关键词
IMPLANT-SUPPORTED OVERDENTURE;
D O I
10.1016/j.prosdent.2022.04.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A technique for the virtual designing of retentive attachment inserts for bar-retained 2-implant mandibular overdentures is described. The bar attachment is scanned intraorally, the retentive insert designed with the MESHMIXER software program, and the file 3D printed in resin, which is replicated in polyetheretherketone (PEEK). The technique offers high-quality inserts with good retention that can replace the conventional nylon inserts and reduce the number of maintenance visits and the frequency of changing the bar attachment. (J Prosthet Dent 2024; 131:1034-7)
引用
收藏
页码:1034 / 1037
页数:4
相关论文
共 23 条
[1]   Milled Bar with PEEK and Metal Housings for Inclined Implants Supporting Mandibular Overdentures: 1-Year Clinical, Prosthetic, and Patient-Based Outcomes [J].
Abdraboh, Abdelrahman Elsaid ;
Elsyad, Moustafa Abdou ;
Mourad, Samah Ibrahim ;
Alameldeen, Hesham Ebrahim .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) :982-989
[2]  
Andreescu CF, 2018, MATER PLAST, V55, P124
[3]   Retentive Characteristics of a New Attachment System for Hybrid Dentures [J].
Arnold, Christin ;
Stampa, Charlotte ;
Schweyen, Ramona ;
Hey, Jeremias ;
Boeckler, Arne .
MATERIALS, 2020, 13 (15) :1-17
[4]   Retention force of plastic clips on implant bars: a randomized controlled trial [J].
Bayer, Stefan ;
Komor, Nathalie ;
Kramer, Annina ;
Albrecht, Dominic ;
Mericske-Stern, Regina ;
Enkling, Norbert .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (12) :1377-1384
[5]   Retentive Properties of Two Stud Attachments with Polyetherketoneketone or Nylon Insert in Mandibular Implant Overdentures [J].
Choi, Jae-Won ;
Yun, Bo-Hyeok ;
Jeong, Chang-Mo ;
Huh, Jung-Bo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (05) :1079-1088
[6]   Retrospective study comparing the clinical outcomes of bar-clip and ball attachment implant-supported overdentures [J].
Chrcanovic, Bruno R. ;
Ghiasi, Peyman ;
Kisch, Jeno ;
Lindh, Liselott ;
Larsson, Christel .
JOURNAL OF ORAL SCIENCE, 2020, 62 (04) :397-401
[7]  
Emera R MK., 2019, Int Dent Res, V9, P92
[8]   Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture [J].
Gonuldas, Fehmi ;
Tokar, Emre ;
Ozturk, Caner .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) :135-141
[9]  
Hammas M., 2018, AL AZHAR DENT J GIRL, V5, P195, DOI [10.21608/ADJG.2018.9531, DOI 10.21608/ADJG.2018.9531]
[10]   Five years follow-up of mandibular 2-implant overdentures on locator or ball abutments: Implant results, patient-related outcome, and prosthetic aftercare [J].
Matthys, Carine ;
Vervaeke, Stijn ;
Besseler, Jos ;
Doornewaard, Ron ;
Dierens, Melissa ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) :835-844