Corrosion detection of steel-reinforced concrete specimens using synthetic aperture radar

被引:0
作者
Raisi, Koosha [1 ]
Abazarsa, Maryam [1 ]
Yu, Tzuyang [1 ]
机构
[1] Univ Massachusetts, Dept Civil & Environm Engn, Shah 200-T,One Univ Ave, Lowell, MA 01854 USA
来源
NONDESTRUCTIVE CHARACTERIZATION AND MONITORING OF ADVANCED MATERIALS, AEROSPACE, CIVIL INFRASTRUCTURE, AND TRANSPORTATION XVIII | 2024年 / 12950卷
关键词
Synthetic Aperture Radar; SAR; steel rebar corrosion; reinforced concrete; ACT; accelerated corrosion; technique; impressed current technique; chloride attack; NDT; SHM; concrete cracking; CHLORIDE THRESHOLD;
D O I
10.1117/12.3010437
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Chloride-induced corrosion attack in steel-reinforced concrete highway bridges is a common and ongoing issue in New England. If left untreated, late-stage corrosion can result in steel rebar section loss, internal stress imbalance, and surface cracks. In recent years, nondestructive testing and evaluation (NDT/E) techniques have been emerging as alternative methods for structural health monitoring (SHM) of civil infrastructure. This paper aims to use synthetic aperture radar (SAR) for corrosion detection of steel-reinforced concrete (RC) panels that were subjected to chloride-induced rebar corrosion. For this purpose, three RC panels (30x30x12.7 cm2) were cast with a No.6 steel rebar (19 mm diameter) at their mid-height with one serving as baseline, and the other two were corroded by accelerated corrosion test (ACT). The RC panels were kept in a temperature-controlled environment (23 - 25. C) since 2017. The RC panels were scanned by a laboratory 10.5 GHz SAR with a 1.5 GHz bandwidth to develop SAR images with two scan ranges of 60 and 70 centimeters. The SAR images were analyzed in time domain and their amplitude parameters were used for corrosion detection. Furthermore, a half-cell potential device was used for verification and quantification in conjunction with out SAR parameters. Our results indicate that the progression of corrosion based on HCP, is correlated with SAR signal parameters such as maximum and integrated, and average SAR amplitudes.
引用
收藏
页数:15
相关论文
共 40 条
[1]  
Al-Saleh Saleh A., 2015, Case Studies in Construction Materials, V3, P78, DOI 10.1016/j.cscm.2015.06.001
[2]  
Alzeyadi A., 2020, PhD thesis
[3]   Remote Detection of Chloride Ion Content in Concrete using SAR [J].
Alzeyadi, Ahmed ;
Yu, Tzuyang .
NONDESTRUCTIVE CHARACTERIZATION AND MONITORING OF ADVANCED MATERIALS, AEROSPACE, CIVIL INFRASTRUCTURE, AND TRANSPORTATION XVII, 2023, 12487
[4]   Remote characterization of chloride content in oven-dried concrete specimens by using synthetic aperture radar image models [J].
Alzeyadi, Ahmed ;
Yu, Tzuyang .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 302
[5]   Subsurface characterization of moisture content and water-to-cement ratio of concrete specimens using remote synthetic aperture radar imaging [J].
Alzeyadi, Ahmed ;
Yu, Tzuyang .
JOURNAL OF APPLIED REMOTE SENSING, 2020, 14 (02)
[6]   Characterization of Moisture Content in a Concrete Panel Using Synthetic Aperture Radar Images [J].
Alzeyadi, Ahmed ;
Yu, Tzuyang .
JOURNAL OF AEROSPACE ENGINEERING, 2019, 32 (01)
[7]   Moisture determination of concrete panel using SAR imaging and the K-R-I transform [J].
Alzeyadi, Ahmed ;
Yu, Tzuyang .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 184 :351-360
[8]  
American Society of Civil Engineers, 2021, Report Card for Americas Infrastructure
[9]   Chloride threshold level for corrosion of steel in concrete [J].
Ann, Ki Yong ;
Song, Ha-Won .
CORROSION SCIENCE, 2007, 49 (11) :4113-4133
[10]  
[Anonymous], 2022, ASTM C876-22b