A Monte Carlo simulation study for SSNTDs used in radon and thoron detection

被引:0
|
作者
Kara, Ayhan [1 ]
Mammadzada, Emil [1 ]
机构
[1] Giresun Univ, Dept Elect & Elect Engn, TR-28200 Giresun, Turkiye
关键词
SSNTD; GEANT; PHITS; SRIM; FLUKA; CasP; DOSE ESTIMATIONS; EXPOSURE; MODEL;
D O I
10.1007/s12648-024-03315-z
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Solid State Nuclear Track Detectors (SSNTDs), despite their simple construction, are highly effective for detecting ion-target interactions. This study examines these interactions using two different SSNTDs commonly used for detecting radon, thoron, and their decay products. The Monte Carlo Simulation Method was utilized to analyze these interactions and compare the performance of the two detectors. Additionally, the study employed various simulation codes, including SRIM, PHITS, CasP, FLUKA, and GEANT, to assess radiation damage and nuclear events in the target detectors when irradiated with alpha particles at different energies.
引用
收藏
页码:639 / 650
页数:12
相关论文
共 50 条
  • [1] Monte Carlo simulation of radon SSNT detectors
    Sima, O
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 181 - 186
  • [2] Monte Carlo simulation experiments on box-type radon dosimeter
    Jamil, Khalid
    Kamran, Muhammad
    Illahi, Ahsan
    Manzoor, Shahid
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 764 : 18 - 23
  • [3] A Simulation Study of Radon and Thoron Discrimination Problem in Case-Control Studies
    Doi, Kazutaka
    Tokonami, Shinji
    Yonehara, Hidenori
    Yoshinaga, Shinji
    JOURNAL OF RADIATION RESEARCH, 2009, 50 (06) : 495 - 506
  • [4] A study on the thoron sensitivity of radon detectors available to Canadians
    Chen, Jing
    Moir, Deborah
    JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (04) : 419 - 425
  • [5] A Monte Carlo simulation study of Nitrogen on LiF(001)
    Sallabi, A. K.
    Dawoud, J. N.
    Jack, D. B.
    APPLIED SURFACE SCIENCE, 2010, 256 (09) : 2974 - 2978
  • [6] Radon and thoron exhalation rate measurements from building materials used in Serbia
    Celikovic, Igor T.
    Pantelic, Gordana K.
    Zivanovic, Milos Z.
    Vukanac, Ivana S.
    Nikolic, Jelena D. Krneta
    Kandic, Aleksandar B.
    Loncar, Boris B.
    NUKLEONIKA, 2020, 65 (02) : 111 - 114
  • [7] A Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy
    Momennezhad, M.
    Toosi, M. T. Bahreyni
    Sadeghi, R.
    Gholamhoseinian, H.
    Nasserr, Sh
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 7 (04): : 223 - 227
  • [8] Study of atomic sputtering and transport dynamics by Monte Carlo simulation
    Ma, Pengfei
    Wu, Xiaocheng
    Zhang, Yapei
    Wang, Dong
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (05)
  • [9] ROOM MODEL BASED MONTE CARLO SIMULATION STUDY OF THE RELATIONSHIP BETWEEN THE AIRBORNE DOSE RATE AND THE SURFACE-DEPOSITED RADON PROGENY
    Sun, Kainan
    Field, R. William
    Steck, Daniel J.
    HEALTH PHYSICS, 2010, 98 (01): : 29 - 36
  • [10] A study on magnetic Barkhausen emission using Monte Carlo simulation
    Sahai, M. K.
    Sasi, B.
    Rao, C. Babu
    Jayakumar, T.
    INSIGHT, 2012, 54 (05) : 262 - 266