Assessment of Debris Extrusion in Curved Canals: An In Vitro Analysis of Various Single-File Endodontic Instrumentation Systems

被引:1
|
作者
Ahmad, Muhammad Zubair [1 ]
机构
[1] Qassim Univ, Coll Dent, Dept Conservat Dent Sci, Buraydah 52571, Saudi Arabia
关键词
APICALLY EXTRUDED DEBRIS; CYCLIC FATIGUE RESISTANCE; SELF-ADJUSTING FILE; WAVEONE GOLD; RECIPROC; RETREATMENT; IRRIGANT; ONESHAPE; DENTIN; VIVO;
D O I
10.1155/2024/8367693
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Rotary single-file endodontic systems are commonly used for root canal treatment. However, very few studies have evaluated the apical extrusion of debris generated by these systems during canal preparation at normal body temperature in laboratory conditions. The aim of this study was to evaluate the amount of apically extruded debris caused by seven different single-file endodontic instrumentation systems at body temperature in mandibular molar teeth with curved root canals. Methods. One hundred forty mandibular first permanent molars were randomly divided into seven groups (n = 20) to be prepared by one of the following systems at 35 degrees C: Reciproc Blue (REC Blue), WaveOne Gold (WOG), One Reci (OR), Neoniti, HyFlex EDM (HEDM), One Curve (OC), or XP Shaper (XPS). Debris was collected into preweighted Eppendorf tubes. The weight of the extruded debris was recorded by subtracting the weight of the tooth-free apparatus from the post-procedure weight. Data were analyzed by one-way ANOVA and Tukey's tests (p <5%). Results. REC Blue, WOG, and OR groups extruded significantly more debris from the apex than XPS, OC, and Neoniti groups (p <0.05). No significant difference was observed among the XPS, OC, Neoniti, and HEDM groups (p >0.05). Conclusion. All the instruments were associated with debris extrusion. However, REC Blue, WOG, and OR extrude significantly more debris than other instruments. The amount of debris with different files was REC Blue > OR > WOG > HEDM > OC > Neoniti > XPS. XPS, Neoniti, and OC caused significantly less extrusion of debris than REC Blue, WOG, and OR.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparative analysis of debris extrusion and instrumentation time among various endodontic file systems: an in vitro study
    Fontana, Carlos Eduardo
    Ribeiro, Beatriz dos Santos
    Davanso, Luana de Carvalho
    de Moura, Joao Daniel Mendonca
    Rocha, Daniel Guimaraes Pedro
    Pelegrine, Rina Andrea
    Bueno, Carlos Eduardo da Silveira
    Pinheiro, Sergio Luiz
    GIORNALE ITALIANO DI ENDODONZIA, 2024, 38 (03): : 43 - 53
  • [2] Influence of operator experience on apical debris extrusion after endodontic instrumentation with different single-file systems
    Fontana, Carlos Eduardo
    da Silveira Bueno, Carlos Eduardo
    Mendonca de Moura, Joao Daniel
    Bastida Pinheiro, Gavila da Rocha
    Trevensoli, Victor Camelotti
    Pelegrine, Rina Andrea
    Pedro Rocha, Daniel Guimaraes
    De Martine, Alexandre Sigrist
    Pinheiro, Sergio Luiz
    GIORNALE ITALIANO DI ENDODONZIA, 2022, 36 (01): : 40 - 47
  • [3] Influence of a glide path on apical extrusion of debris during canal preparation using single-file systems in curved canals
    Topcuoglu, H. S.
    Duzgun, S.
    Akpek, F.
    Topcuoglu, G.
    Akti, A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (06) : 599 - 603
  • [4] Apical extrusion of debris with different rotary and reciprocating single-file endodontic instrumentation systems: a systematic review and meta-analysis protocol
    Ahmad, Muhammad Zubair
    Sadaf, Durre
    MacBain, Marcy McCall
    Mohamed, Ahmed Nabil
    BMJ OPEN, 2020, 10 (09): : e038502
  • [5] Effect of mode of rotation on apical extrusion of debris with four different single-file endodontic instrumentation systems: Systematic review and meta-analysis
    Ahmad, Muhammad Zubair
    Sadaf, Durre
    MacBain, Marcy McCall
    Merdad, Khalid A.
    AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (01) : 202 - 218
  • [6] Quantitative Evaluation of Apically Extruded Debris in Root Canals prepared by Single-file Reciprocating and Single File Rotary Instrumentation Systems: A Comparative In vitro Study
    Sinha, Sonal
    Singh, Konark
    Singh, Anju
    Priya, Swati
    Kumar, Avanindra
    Kawle, Sahil
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1398 - S1401
  • [7] Assessing Fracture Strength in Root Canals: A Comparative In-Vitro Analysis of Single-File Instrumentation Systems
    Asiri, Ashwaq
    MEDICINA BALEAR, 2024, 39 (04):
  • [8] Apical Extrusion of Debris Using Self-Adjusting File, Reciprocating Single-file, and 2 Rotary Instrumentation Systems
    Kocak, Sibel
    Kocak, Mustafa Murat
    Saglam, Baran Can
    Turker, Sevinc Aktemur
    Sagsen, Burak
    Er, Ozgur
    JOURNAL OF ENDODONTICS, 2013, 39 (10) : 1278 - 1280
  • [9] Canal shaping of different single-file systems in curved root canals
    D'Amario, Maurizio
    De Angelis, Francesco
    Mancino, Maddalena
    Frascaria, Massimo
    Capogreco, Mario
    D'Arcangelo, Camillo
    JOURNAL OF DENTAL SCIENCES, 2017, 12 (04) : 328 - 332
  • [10] A COMPARISON OF ENDODONTIC FILE TIP DESIGN AS TO THEIR EFFECT IN INSTRUMENTATION OF CURVED CANALS
    FELCHER, TR
    STILES, MJ
    WALTON, RE
    JOURNAL OF DENTAL RESEARCH, 1987, 66 : 344 - 344