On the displacement control performance of base-isolated structures incorporating nonlinear negative stiffness device

被引:6
作者
Zhang, Yafei [1 ]
Hu, Yuchen [1 ]
Zhou, Zihao [2 ]
Li, Ning [1 ,3 ,4 ,5 ]
Zhang, Dan [6 ]
Ma, Yuhong [7 ]
机构
[1] Tianjin Univ, Sch Civil Engn, Tianjin 300350, Peoples R China
[2] Byd Auto Ind Co Ltd, Automot Engn Res Inst, Shenzhen 518000, Peoples R China
[3] Tianjin Univ, State Key Lab Hydraul Engn Intelligent Construct &, Minist Educ, Tianjin 300350, Peoples R China
[4] Tianjin Univ, Key Lab Coast Civil Struct Safety, Minist Educ, Tianjin 300350, Peoples R China
[5] China Earthquake Adm, Key Lab Earthquake Engn Simulat & Seism Resilience, Tianjin 300072, Peoples R China
[6] Hebei Univ Technol, Sch Civil & Transportat Engn, Tianjin 300401, Peoples R China
[7] Guanzhou Univ, Earthquake Engn Res & Test Ctr, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Base -isolated structures; Negative stiffness device; Harmonic balance method; Displacement transmissibility; Nonlinear Duffing equation; SEISMIC ISOLATION; SYSTEMS; PROTECTION;
D O I
10.1016/j.istruc.2024.106558
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Low -frequency dominant far -field harmonic -like long period ground motions (FGMs) excitations have the potential to amplify the seismic response of base -isolated structures (BIS) and may result in isolator displacements exceeding their maximum limits. The application of negative stiffness devices (NSD) in isolated structures primarily focuses on SDOF systems, which fails to capture the displacement response of the superstructure on the isolation story. To address this issue, this study proposes the application of NSD to a 2DOF system in a BIS, with root mean square value as the metric for displacement transmissibility. Firstly, the displacement transmissibility of base -isolated structures with negative stiffness devices (BIS-NSD) and BIS is derived using the triple -harmonic balance (T-HB) method and the single -harmonic balance (S-HB) method, respectively. Subsequently, the applicability of the T-HB method and the S-HB method in obtaining analytical solution for the displacement transmissibility of BIS-NSD and BIS is revealed and validated through numerical solution. Parameters are selected based on fixed-point theorem for comparative analysis of the displacement and acceleration transmissibility between BIS-NSD and BIS. Finally, a comparative analysis between BIS-NSD and BIS under FGMs confirms the application advantages of NSD. The results indicate that compared to BIS, BIS-NSD significantly reduces the displacement transmissibility of the superstructure and the isolation story in the low -frequency range. As the primary resonance frequency decreases, NSD widens the vibration bandwidth of BIS. BIS-NSD effectively mitigates the increase in displacement caused by low -frequency ground motions. The acceleration transmissibility demonstrates that, without sacrificing the acceleration of the superstructure, it effectively controls the displacement of the isolation story.
引用
收藏
页数:14
相关论文
共 44 条
[1]  
[Anonymous], 2021, Standard for Seismic Isolation Design of Building, Ministry of Housing and UrbanRural Development of the People's Republic of China
[2]   Static analysis of a passive vibration isolator with quasi-zero-stiffness characteristic [J].
Carrella, A. ;
Brennan, M. J. ;
Waters, T. P. .
JOURNAL OF SOUND AND VIBRATION, 2007, 301 (3-5) :678-689
[3]   Force and displacement transmissibility of a nonlinear isolator with high-static-low-dynamic-stiffness [J].
Carrella, A. ;
Brennan, M. J. ;
Waters, T. P. ;
Lopes, V., Jr. .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2012, 55 (01) :22-29
[4]   Analytical and numerical investigations of base isolation system with negative stiffness devices [J].
Chen, Peng ;
Wang, Bin ;
Dai, Kaoshan ;
Li, Tao .
ENGINEERING STRUCTURES, 2022, 268
[5]   Three-Dimensional Base Isolation Using Vertical Negative Stiffness Devices [J].
Cimellaro, Gian Paolo ;
Domaneschi, Marco ;
Warn, Gordon .
JOURNAL OF EARTHQUAKE ENGINEERING, 2020, 24 (12) :2004-2032
[6]   Shake table tests for the seismic fragility evaluation of hospital rooms [J].
Cosenza, Edoardo ;
Di Sarno, Luigi ;
Maddaloni, Giuseppe ;
Magliulo, Gennaro ;
Petrone, Crescenzo ;
Prota, Andrea .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (01) :23-40
[7]  
Dicleli M., 2002, Journal of Bridge Engineering, V7, P94, DOI DOI 10.1061/(ASCE)1084-0702(2002)7:2(94)
[8]   Experimental seismic performance of a base-isolated building with displacement limiters [J].
Du, Hongkai ;
Wang, Yuandong ;
Han, Miao ;
Ibarra, Luis F. .
ENGINEERING STRUCTURES, 2021, 244
[9]   Comprehensive design optimization of vertical seismic absorbers incorporating sensitivity and robust analysis: A case study of the KDamper [J].
Gkikakis, Antonios E. ;
Kapasakalis, Konstantinos A. ;
Sapountzakis, Evangelos J. .
ENGINEERING STRUCTURES, 2024, 301
[10]   A review of rolling-type seismic isolation: Historical development and future directions [J].
Harvey, P. Scott, Jr. ;
Kelly, Karah C. .
ENGINEERING STRUCTURES, 2016, 125 :521-531