Determination of Enantiomeric Impurity in Tegoprazan Drug Substance by HPLC

被引:0
|
作者
Zhang, Lei [1 ]
Duan, Shutao [2 ]
Xu, Shujuan [1 ]
Wang, Lihua [1 ]
Shen, Yingde [1 ]
机构
[1] Linyi Inspect & Testing Ctr, Linyi, Peoples R China
[2] Shandong Ctr Food & Drug Evaluat & Inspect, Jinan, Peoples R China
来源
SEPARATION SCIENCE PLUS | 2024年 / 7卷 / 11期
关键词
alpha 1-acid glycoprotein; enantiomer; high-performance liquid chromatography; tegoprazan; CHIRAL STATIONARY PHASES; SEPARATION; RESOLUTION;
D O I
10.1002/sscp.202400125
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tegoprazan is a novel potassium-competitive acid blocker used for gastroesophageal reflux disease. It is administered as the (S)- and (R)-enantiomers are considered impurities that should be controlled. The objective of this work was to establish a chiral analytical method for the determination of the enantiomeric impurity of tegoprazan in the drug substance by high-performance liquid chromatography (HPLC). Enantioselective separation was performed on a Chiralpak alpha1-acid glycoprotein (AGP) column (4.6 mm x 250 mm, 5.0 mu m) at 30 degrees C utilizing a mobile phase consisting of 5 mmol L-1 ammonium acetate buffer (pH 6.0) and 2-propanol (93:7, v/v) at a flow rate of 0.7 mL min-1 with a detection wavelength of 220 nm. The effects of chromatographic conditions, including the type and concentration of organic modifiers, buffer pH, buffer concentration, flow rate, and column temperature, were thoroughly investigated. Under the optimized conditions, the resolution between (S)- and (R)-tegoprazan was greater than 3.0. Moreover, the developed method was validated in terms of linearity, limits of detection (LOD) and quantitation (LOQ), accuracy, precision, and stability. Each enantiomer showed a good linear relationship over the concentration range of 1.0-100 mu g mL-1, with the correlation coefficient of 0.9999. The LOD and LOQ were 0.1 and 0.3 mu g mL-1, respectively. In addition, the recoveries ranged from 94.10% to 99.39% with a relative standard deviation (RSD) of 1.9%. Application of this proposed method to determine the enantiomeric impurity in tegoprazan drug substance proved satisfactory. The quantitative results were about 2.0%, demonstrating that enantiomeric impurity remained in the tegoprazan drug substance and should be controlled in the quality criteria.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A specific chiral HPLC method for lifitegrast and determination of enantiomeric impurity in drug substance, ophthalmic product and stressed samples
    Ugur, Merve
    Atici, Esen Bellur
    Ozkan, Sibel A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 242
  • [2] The determination of a potential impurity in Thalidomide drug substance and product by HPLC with indirect UV detection
    Li, JY
    Jaworsky, MS
    Stirling, DI
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (01) : 19 - 27
  • [3] Simple Isocratic HPLC Method for Determination of Enantiomeric Impurity in Besifloxacin Hydrochloride
    Kumar, G. Pradeep
    Srivastava, Vishal
    Khandelwal, Kiran
    Kumar, Rajesh
    Hiriyanna, S. G.
    Kumar, Ajay
    Kumar, Pramod
    CHIRALITY, 2016, 28 (09) : 628 - 632
  • [4] STUDIES ON THE USE OF HPLC FOR THE DETERMINATION OF DRUG ENANTIOMERIC PURITY
    GELBER, L
    NEUMEYER, JL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 9 - MEDI
  • [5] Impurity profile study of lopinavir and validation of HPLC method for the determination of related substances in lopinavir drug substance
    Chitturi, Sreenivasa Rao
    Bharathi, Ch.
    Reddy, A. V. Raghava
    Reddy, K. Chandrasekhar
    Sharma, Hemant Kumar
    Handa, Vijay Kumar
    Dandala, Ramesh
    Bindu, V. Hima
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (05) : 1430 - 1440
  • [6] DETERMINATION OF MAJOR IMPURITY IN CHLORDIAZEPOXIDE FORMULATIONS AND DRUG SUBSTANCE
    FRENCH, WN
    MATSUI, FF
    SMITH, SJ
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1975, 64 (09) : 1545 - 1547
  • [7] Development and validation of indirect RP-HPLC method for enantiomeric purity determination of D-cycloserine drug substance
    Karthikeyan, K.
    Arularasu, G. T.
    Ramadhas, R.
    Pillai, K. Chandrasekara
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 850 - 854
  • [8] Development, Robustness by Design Expert and Validation of a Method for Enantiomeric Impurity Content Determination in Pretomanid Drug Substance and Pharmaceutical Dosage Form
    Surapuraju, Pavan Kumar Raju
    Juturu, Raveendra Reddy
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2024, 62 (04) : 311 - 320
  • [9] Development and Validation of a Reversed-Phase HPLC Method for Determination of Lesatropane and Enantiomeric Impurity
    Yang, Li-Min
    Xie, Yi-Fan
    Gu, Zhou-Hui
    Wang, Ai-Ling
    Chen, Hong-Zhuan
    Lu, Yang
    CHIRALITY, 2011, 23 (08) : 581 - 584
  • [10] Improving the Current European Pharmacopoeia Enantio-Selective HPLC Method for the Determination of Enantiomeric Purity in Atorvastatin Calcium Salt Drug Substance
    Mammone, Francesca Romana
    Sadutto, Daniele
    D'Ettorre, Giulia
    Mosca, Antonina
    Cirilli, Roberto
    SEPARATIONS, 2024, 11 (05)