CBCT assessment of mandibular molar furcation following root canal retreatment using engine-driven instruments

被引:0
作者
Souza, Paulo Otavio Carmo [1 ]
Bueno, Mike Reis [2 ]
Silva, Brunno Santos de Freitas [1 ]
Gregoris, Luiz Eduardo [1 ]
Costa, Nadia do Lago [1 ]
Estrela, Carlos [1 ]
机构
[1] Univ Fed Goias UFGO, Dept Stomatol Sci, Goiania, GO, Brazil
[2] Sao Leopoldo Mand Univ, Fac Dent, Dept Radiol, Campinas, SP, Brazil
来源
BRAZILIAN ORAL RESEARCH | 2024年 / 38卷
关键词
Root Canal Therapy; Root Canal Preparation; Cone-Beam Computed Tomography; Software; CORONAL PRE-ENLARGEMENT; RISK;
D O I
10.1590/1807-3107bor-2024.vol38.0087
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study employed e-Vol DXS cone beam computed tomography (CBCT) software to assess dentin remnants in the furcation area of mesial canals in mandibular molars during root Race Evo (R), Protaper Gold (R)) were subjected to RCR, and CBCT images were captured before (T1) and after (T2) treatment. Measurements of remaining dentin thickness at 1 mm and 3 mm below the furcation were scrutinized. Results revealed no significant differences in mean thicknesses of mesiobuccal (MB) and mesiolingual (ML) canals at 1 mm and 3 mm from the furcation pre-treatment (T1). Post-treatment (T2) showed analogous findings, with no significant differences in mean thicknesses. However, disparities were found between MB and ML canals at both distances, both before and after retreatment. In essence, the evaluated instruments exhibited safety in RCR, implying that they are appropriate for use in critical areas of mandibular molars without inducing excessive wear. This study underscores the reliability of these instruments in navigating danger zones during RCR, and contributes valuable insights for dental practitioners who handle complex root canal scenarios in mandibular molars.
引用
收藏
页数:9
相关论文
共 23 条
[1]   THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL [J].
ABOURASS, M ;
FRANK, AL ;
GLICK, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) :792-794
[2]  
Akhlaghi Nahid Mohammadzadeh, 2015, Eur J Dent, V9, P228, DOI 10.4103/1305-7456.156833
[3]   Mechanical Properties of the New Generation RACE EVO and R-Motion Nickel-Titanium Instruments [J].
Basturk, Fatima Betul ;
Ozyurek, Taha ;
Uslu, Gulsah ;
Gundogar, Mustafa .
MATERIALS, 2022, 15 (09)
[4]  
Bueno Mike R, 2019, Braz. Dent. J., V30, P3
[5]  
Bueno Mike R., 2018, Braz. Dent. J., V29, P517, DOI 10.1590/0103-6440201802455
[6]   A review of instrumentation kinematics of engine-driven nickel-titanium instruments [J].
Capar, I. D. ;
Arslan, H. .
INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (02) :119-135
[7]   Evaluation in the danger zone of mandibular molars after root canal preparation using novel CBCT software [J].
de Sousa, Vinicius Caixeta ;
Goncalves de Alencar, Ana Helena ;
Bueno, Mike Reis ;
Decurcio, Daniel de Almeida ;
Estrela, Cyntia Rodrigues Araujo ;
Estrela, Carlos .
BRAZILIAN ORAL RESEARCH, 2022, 36 :1-12
[8]   Anatomical danger zone reconsidered: a micro-CT study on dentine thickness in mandibular molars [J].
De-Deus, G. ;
Rodrigues, E. A. ;
Belladonna, F. G. ;
Simoes-Carvalho, M. ;
Cavalcante, D. M. ;
Oliveira, D. S. ;
Souza, E. M. ;
Giorgi, K. A. ;
Versiani, M. A. ;
Lopes, R. T. ;
Silva, E. J. N. L. ;
Paciornik, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (10) :1501-1507
[9]   Comparison of Endodontic Failures between Nonsurgical Retreatment and Endodontic Surgery: Systematic Review and Meta-Analysis with Trial Sequential Analysis [J].
Dioguardi, Mario ;
Stellacci, Camilla ;
La Femina, Lucia ;
Spirito, Francesca ;
Sovereto, Diego ;
Laneve, Enrica ;
Manfredonia, Massimo Francesco ;
D'Alessandro, Alfonso ;
Ballini, Andrea ;
Cantore, Stefania ;
Lo Muzio, Lorenzo ;
Troiano, Giuseppe .
MEDICINA-LITHUANIA, 2022, 58 (07)
[10]   Evaluation of Root Canal Transportation, Centering Ratio, and Remaining Dentin Thickness Associated with Pro Taper Next Instruments with and without Glide Path [J].
Elnaghy, Amr M. ;
Elsaka, Shaymaa E. .
JOURNAL OF ENDODONTICS, 2014, 40 (12) :2053-2056