Noninvasive Real-Time Glucose Monitoring Is in the Near Future

被引:4
作者
Hirsch, Irl B. [1 ]
Tirosh, Amir [2 ]
Navon, Ami [3 ]
机构
[1] Univ Washington, Sch Med, UW Med Diabet Inst, 4245 Roosevelt Way NE, Seattle, WA 98109 USA
[2] Sheba Med Ctr, Div Endocrinol Diabet & Metab, Ramat Gan, Israel
[3] Weizmann Inst Sci, Dept Immunol & Regenerat Biol, Rehovot, Israel
关键词
Noninvasive; Continuous glucose monitoring; Radiofrequency;
D O I
10.1089/dia.2024.0009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Since the introduction of continuous glucose monitoring (CGM) technology, developers have rigorously researched the feasibility of creating a noninvasive glucose monitoring device. In a recent pilot study, investigators reported a strong correlation between glucose values obtained from novel noninvasive monitoring device (GWave) values to venous and capillary glucose measurements.Research Design and Methods: We investigated whether the level of accuracy observed in the pilot study could be reproduced in a larger cohort, using a smaller third-generation manufacturable device (Gen III GWave) containing a standardized sensor chip that can be mass produced for commercial use. The evaluation assessed concordance with capillary blood glucose, reproducibility between two Gen III devices, and accuracy during insulin-induced hypoglycemia.Results: Assessment of samples from 75 subjects (type 2 diabetes, n = 6; type 1 diabetes, n = 28; nondiabetic pregnant subjects, n = 10; and nondiabetic, n = 31) showed that 97% of values were in Zone A with 3% in Zone B of the Clarke Error Grid, with a mean absolute relative difference of 6.7% from reference blood glucose. Comparison between two independent Gen III GWave devices demonstrated reproducibility between the sensors (R2 = 0.95), with 100% of values within Zone A. In the hypoglycemia assessment, measurements from the Gen III sensor tightly followed the capillary glucose measurements down to 42 mg/dL (2.3 mmol/L), whereas the CGM measurements from two different CGM only converged with the GWave and capillary glucose readings after 90 min of decreasing glucose levels.Conclusion: Our results show promise as potentially the first noninvasive technology. Future studies will focus on larger number of people in all glucose ranges. Real-time noninvasive blood glucose monitoring is possible using GWave technology.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 19 条
[1]  
Alva Shridhara, 2008, J Diabetes Sci Technol, V2, P546
[2]  
Clarke William L, 2005, Diabetes Technol Ther, V7, P776, DOI 10.1089/dia.2005.7.776
[3]   Poor Reliability and Poor Adherence to Self-Monitoring of Blood Glucose Are Common in Women With Gestational Diabetes Mellitus and May Be Associated With Poor Pregnancy Outcomes [J].
Cosson, Emmanuel ;
Baz, Baz ;
Gary, Francoise ;
Pharisien, Isabelle ;
Minh Tuan Nguyen ;
Sandre-Banon, Dorian ;
Jaber, Yahya ;
Cussac-Pillegand, Camille ;
Banu, Isabela ;
Carbillon, Lionel ;
Valensi, Paul .
DIABETES CARE, 2017, 40 (09) :1181-1186
[4]  
Engler Robert, 2018, Clin Diabetes, V36, P50, DOI 10.2337/cd17-0053
[5]  
Ginsberg Barry H, 2009, J Diabetes Sci Technol, V3, P903
[6]   GWave-A Novel Noninvasive Glucose Blood Monitoring Radio Wave-Based Technology [J].
Hirsch, Irl B. ;
Navon, Ami .
DIABETES, 2023, 72
[7]   Self-monitoring of blood glucose levels and glycemic control: The Northern California Kaiser Permanente Diabetes Registry [J].
Karter, AJ ;
Ackerson, LM ;
Darbinian, JA ;
D'Agostino, RB ;
Ferrara, A ;
Liu, J ;
Selby, JV .
AMERICAN JOURNAL OF MEDICINE, 2001, 111 (01) :1-9
[8]   CGM for insulinoma screening: a prospective and observational case-control study [J].
Ma, Jingyuan ;
Huang, Xinyu ;
Zhao, Jungong ;
Lu, Jingyi ;
Lu, Wei ;
Bao, Yuqian ;
Zhou, Jian ;
Han, Junfeng .
ENDOCRINE-RELATED CANCER, 2021, 28 (05) :291-300
[9]  
MEDTECHDIVE, CGM PATIENTS SEEN RI
[10]   Adherence of self-monitoring of blood glucose in persons with type 1 diabetes in Sweden [J].
Mostrom, Peter ;
Ahlen, Elsa ;
Imberg, Henrik ;
Hansson, Per-Olof ;
Lind, Marcus .
BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01)