摘要
PurposeRobotic-assisted total knee arthroplasty (RA-TKA) is an increasingly popular alternative that may increase the accuracy of conventional TKA techniques. This study aims to evaluate RA-TKA accuracy and compare its radiographic and clinical outcomes to conventional TKA (cTKA). MethodsA retrospective examination of patients with bi- or tricompartmental knee osteoarthritis who underwent RA-TKA (RObotic Surgical Assistant system) or cTKA and were prospectively documented in the TKA registry. Accuracy was assessed using standardized radiographic implant position evaluations, namely femoral and tibial coronal angles and femoral and tibial sagittal angles. Baseline demographics, surgery details and 6- and 12-month post-TKA patient-reported outcomes (PROMs; e.g., Oxford Knee Score [OKS] and Core Outcome Measures Index) were compared between RA-TKA and propensity score-matched cTKA patients. ResultsOverall correlation between preset and 6-week postoperative angle measurements for RA-TKA was low with significant differences noted only for mean tibial sagittal angles (84.6 degrees [RA-TKA] vs. 82.3 degrees [cTKA]) (p < 0.001). The study groups were demographically similar, although RA-TKA patients had slightly longer operative times and higher blood loss but shorter inpatient stays. There were sustainable improvements in all PROMs already at 6 months, yet RA-TKA patients had significantly higher OKS values over their conventional counterparts at this time point. ConclusionRadiological and clinical outcomes were comparable between RA-TKA and cTKA. The robotic-assisted system demonstrated higher accuracy in the coronal than sagittal plane and RA-TKA patients achieved better short-term outcomes for pain and disability. While both methods are similar in the hands of a skilled surgeon, long-term studies are necessary to establish clear method superiority. Level of EvidenceTherapeutic, Level III.
引用
收藏
页码:3239 / 3251
页数:13
相关论文
共 36 条
  • [1] How to document and report orthopedic complications in clinical studies? A proposal for standardization
    Audige, Laurent
    Goldhahn, Sabine
    Daigl, Monica
    Goldhahn, Joerg
    Blauth, Michael
    Hanson, Beate
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (02) : 269 - 275
  • [2] Concepts and techniques of a new robotically assisted technique for total knee arthroplasty: the ROSA knee system
    Batailler, Cecile
    Hannouche, Didier
    Benazzo, Francesco
    Parratte, Sebastien
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2049 - 2058
  • [3] New Technologies in Knee Arthroplasty: Current Concepts
    Batailler, Cecile
    Swan, John
    Sappey Marinier, Elliot
    Servien, Elvire
    Lustig, Sebastien
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (01) : 1 - 18
  • [4] Robotics in Total Knee Arthroplasty
    Bautista, Maria
    Manrique, Jorge
    Hozack, William J.
    [J]. JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 600 - 606
  • [5] Robotic-assisted mechanically aligned total knee arthroplasty does not lead to better clinical and radiological outcomes when compared to conventional TKA: a systematic review and meta-analysis of randomized controlled trials
    Bensa, Alessandro
    Sangiorgio, Alessandro
    Deabate, Luca
    Illuminati, Andrea
    Pompa, Benedetta
    Filardo, Giuseppe
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (11) : 4680 - 4691
  • [6] Introduction of ROSA robotic-arm system for total knee arthroplasty is associated with a minimal learning curve for operative time
    Bolam, Scott M.
    Tay, Mei Lin
    Zaidi, Faseeh
    Sidaginamale, Raghavendra P.
    Hanlon, Michael
    Munro, Jacob T.
    Monk, A. Paul
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [7] Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not?
    Bourne, Robert B.
    Chesworth, Bert M.
    Davis, Aileen M.
    Mahomed, Nizar N.
    Charron, Kory D. J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 57 - 63
  • [8] Fleischer W., 2012, DEUT ARZTEBLATT, V109, P2555
  • [9] Evaluation of the Painful Total Knee Arthroplasty
    Flierl, Michael A.
    Sobh, Ali H.
    Culp, Brian M.
    Baker, Erin A.
    Sporer, Scott M.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (20) : 743 - 751
  • [10] Research electronic data capture (REDCap)-A metadata-driven methodology and workflow process for providing translational research informatics support
    Harris, Paul A.
    Taylor, Robert
    Thielke, Robert
    Payne, Jonathon
    Gonzalez, Nathaniel
    Conde, Jose G.
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2009, 42 (02) : 377 - 381