Examining the influence of number of inlets and outlets on the topology optimization design of battery liquid cooling plate

被引:14
作者
Zhan, Sen [1 ]
Chen, Yao [1 ]
Yin, Yanli [1 ]
Li, Zonghua [2 ]
Yu, Cheng [2 ]
机构
[1] Chongqing Jiaotong Univ, Chongqing Key Lab Urban Rail Transit Vehicle Syst, Chongqing 400074, Peoples R China
[2] Deep Blue Automot Technol Co Ltd, Chongqing 401133, Peoples R China
关键词
Lithium -ion power battery; Battery thermal management system; Liquid cooling plate; Topology optimization; Number of inlets and outlets; THERMAL MANAGEMENT; HEAT-TRANSFER; CELL;
D O I
10.1016/j.applthermaleng.2024.123691
中图分类号
O414.1 [热力学];
学科分类号
摘要
The trade-off between enhancing the thermal performance of battery liquid cooling plates and reducing their pumping power consumption remains an unresolved issue. In order to solve this problem, this study proposes a multi -inlet and multi -outlet liquid cooling plate design method based on topology optimization. Through topology optimization, 2D models with various numbers of inlets and outlets under different arrangements were obtained, and were extended into 3D numerical models. The study investigated the impact of inlet and outlet arrangement direction, quantity, channel depth, and total mass flow rate at the inlet on the performance of liquid cooling plates. The findings indicated that Topology -optimized liquid cooling plates exhibit superior flow and heat exchange performance compared to traditional straight -channel liquid cooling plates. Arranging the inlet and outlet along the width direction of the rectangular liquid cooling plate can reduce the pressure drop. As for the number of inlets and outlets along the width direction, employing three inlets and three outlets, as opposed to a single inlet and outlet, reduced pump power by 29.04 %, increased the heat transfer coefficient by 28.41 %, increased temperature uniformity by 39.13 %, and boosted the comprehensive evaluation factor by 80.7 %. Furthermore, the channel depth of 3 mm, with a total mass flow rate of 15 g/s at the inlet, was the ideal choice for achieving a balance between system heat dissipation and power consumption. Finally, the accuracy of the simulation was validated through experiments.
引用
收藏
页数:19
相关论文
共 50 条
[41]   Topology Optimization Design of a Microchannel Plate Based on Velocity Distribution [J].
Qiu, Guiqian ;
Wei, Peng ;
Huang, Pingnan ;
Pan, Minqiang .
CHEMICAL ENGINEERING & TECHNOLOGY, 2021, 44 (04) :681-689
[42]   3D topology optimization of heat sinks for liquid cooling [J].
Sun, Sicheng ;
Liebersbach, Piotr ;
Qian, Xiaoping .
APPLIED THERMAL ENGINEERING, 2020, 178
[43]   Design and optimization of mini-channel cooling plate with partially embedded porous fins for thermal management of lithium-ion battery modules [J].
Wu, Mao-Sung .
JOURNAL OF POWER SOURCES, 2025, 654
[44]   Numerical study on heat dissipation of double layer enhanced liquid cooling plate for lithium battery module [J].
Zhang, Bao ;
Li, Yan ;
Chen, Zhan-Feng ;
Wang, Wen ;
Shi, Guang ;
Yang, He .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 206
[45]   A Novel Liquid Cooling Battery Thermal Management System With a Cooling Plate Based on Biomimetic Fractal Channels [J].
Tang, Zhiguo ;
Xiang, Yi ;
Li, Man ;
Cheng, Jianping .
JOURNAL OF ELECTROCHEMICAL ENERGY CONVERSION AND STORAGE, 2024, 21 (04)
[46]   Topology optimization-based design and performance analysis of liquid cooling plates for lithium-ion batteries [J].
Pan, Chaofeng ;
Wu, Jiaxin ;
Wang, Jian ;
Wang, Limei ;
Liu, Liang .
JOURNAL OF ENERGY STORAGE, 2025, 124
[47]   Optimization design of flow path arrangement and channel structure for lithium-ion battery cooling plate based on the three-field synergy principle [J].
Shi, Da ;
He, Ya-Ling ;
Wang, Shuo ;
Qiao, Wei ;
Liu, Zhan-bin .
APPLIED THERMAL ENGINEERING, 2025, 264
[48]   A Comprehensive Flowrate Optimization Design for a Novel Air-Liquid Cooling Coupled Battery Thermal Management System [J].
Chen, Siqi ;
Wei, Xuezhe ;
Garg, Akhil ;
Gao, Liang .
JOURNAL OF ELECTROCHEMICAL ENERGY CONVERSION AND STORAGE, 2021, 18 (02)
[49]   An Optimization Study on the Operating Parameters of Liquid Cold Plate for Battery Thermal Management of Electric Vehicles [J].
Wei, Lichuan ;
Zou, Yanhui ;
Cao, Feng ;
Ma, Zhendi ;
Lu, Zhao ;
Jin, Liwen .
ENERGIES, 2022, 15 (23)
[50]   Topology optimization for liquid-based battery thermal management system under varied charge rates [J].
Wanittansirichok, Vichapol ;
Mongkholphan, Kanich ;
Chaowalitbumrung, Naruemon ;
Sukjai, Yanin ;
Promoppatum, Patcharapit .
JOURNAL OF ENERGY STORAGE, 2022, 55